• 제목/요약/키워드: current body size

검색결과 220건 처리시간 0.028초

재래닭의 경영 및 판매 실태에 관한 조사 연구 (A Research on Current Farm Management and Marketing Situation of Korean Native Chickens)

  • 한성욱;박종수;오봉국;정선부;이규호;최연호;김재홍;여정수;하정기
    • 한국가금학회지
    • /
    • 제22권3호
    • /
    • pp.167-178
    • /
    • 1995
  • The purpose of this research was to get basic information for the development of Korean native chicken industry by reviewing the current native chicken farm management and marketing situation of native chicken products(meat and eggs). The research was carried on the basis of the farm field survey covering 210 native chicken feeders out of 9 different local areas, and the results were as follows ; 1. Average raising size of native chicken flocks of sample farms was 1,787 heads and about 50% of those farms raised less than 500 heads chickens for self-sufficiency or on the side. 2. Most farmers made the decision to start on feeding native chickens in small scale with small amount of capital without sound feeding program, and their decision was mainly influenced by recommendation of mass-media( 19.5%) and neighbors (17.2%). 3. The average income per farm earned by raising the native chickens was 13,719 Won, and income per head of chicken was 8,800 Won. 4. About 40% of feeders expressed that the poor marketing management and lack of capital were the bottleneck to native chicken farm management. 5. About 70% of feeders evaluated the prospect of native chicken industry positively and so, about 60% of feeders hoped to expand the raising size in the future. 6. Most farmers directry made a bargain with marketer including middleman and enduser in selling the chicken products because there was not established special marketing system for native chicken products. 7. The sales age of native broiler was about 16~20 weeks and average body weight of broiler was 1.5~2.0 kg. And farm recieved price was not decided on the basis of each body weight or meat quality but only number of heads. 8. The average first egg-laying age of chickens was about 165 days and average annual laying rate was only about 56%. 9. In order to develop the successful Korean native chicken industry, followings are recommended ; 1) Reducing the production costs and increasing the productivity of native chickens should be carried out through technological research and development for sound feeding program of native chickens and sufficient fund supply. 2) Orderly native chicken marketing and pricing system should be established to give good vision about native chickens to farmers and to delight the consumers. 3) The measures for product differentiation including meat quality and nutritional value of native chicken products against other improved chickens should be actively taken by feeders and government.

  • PDF

성인 여성복의 KS 치수 표준 개정을 위한 제안 연구 (A Study on the Suggestion for the Revision of Standard Sizing System for Female Adult's Garments)

  • 남윤자;이정임;정재은
    • 한국의류산업학회지
    • /
    • 제16권5호
    • /
    • pp.776-784
    • /
    • 2014
  • KS K 0051(2009) was established in 1990 and revised in 1994, 1999, 2004 and 2009. Recently the structure of apparel production and distribution are changing like as small quantity batch production, increase of importing abroad apparel and increase of on-line shopping mall. Based on Social and economic conditions, examine the potential for use of KS K 0051(2009) standard sizing system for female adult's garments are needed. Through which, it was intended to suggestion for the revision of standard sizing system for female adult's garments which can facilitate communication among consumer, producer and sellers. The improvement point was discussed through review of the current KS K 0051 (2009) and abroad standard sizing system for female adult's garments, ISO 3637(1977), ISO 4416(1981), BS EN 13402-2(2002), BS EN 13402-3(2004), JIS L 4005(2001) and GB/T 1335.2(2008). Also, the revision of standard sizing system for female adult's garments was suggested using data of 6th Size Korea. As a result of this study, in the revision, formal wear, casual wear, training wear and under wear were separated to simplify the classification and the classification of body type were excluded. Also, it is possible that size designation was simplified through optional notation and letter code based on bust girth could be marked together in casual wear.

DP 590 GA 강재의 압흔형상과 동저항을 이용한 인버터 DC 용접기의 통계적 품질평가 (A Statistical Quality Evaluation Using Indentation Geometry and Dynamic Resistance Of Inverter DC Resistance Spot Welding)

  • 안주선;김재성;이보영;은종목;김동철
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.68-68
    • /
    • 2009
  • 최근에 자동차 차체 경량화를 목적으로 개발된 고장력강의 용접품질 향상을 위해 인버터 DC 점용접기가 많이 사용되어지고 있다. 본 연구에서는 국내에서 개발된 인버터 DC 용접기를 사용하여 자동차용 590MPa 고장력 냉연강판(CR, SPFC 590RA)과 아연 도금 강판 (GA- EZFFC 590RA)의 용접품질을 평가하였다. 용접에 사용된 기본 조건은 인장 전단 시험을 통하여 결정하였으며, 동저항, 압흔 자국과 너겟 지름, 인장강도와의 관계를 통계적 방법으로 분석하였으며, 이를 활용하여 고장력 강판의 동저항과 압흔 자국에 따라 너겟 지름과 용접강도를 예측하는 비파괴적 용접 품질 평가 방법을 제시하였다.

  • PDF

도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS) (320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection)

  • 오동인;이민형;김희진;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

고성능 저전압 모바일향 90nm DRAM을 위한 비대칭 채널구조를 갖는 Recess Channel Array Transistor의 제작 및 특성 (A study of Recess Channel Array Transistor with asymmetry channel for high performance and low voltage Mobile 90nm DRAMs)

  • 김상범;이진우;박양근;신수호;이은철;이동준;배동일;이상현;노병혁;정태영;김길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.163-166
    • /
    • 2004
  • 모바일향 90nm DRAM을 개발하기 위하여 비대칭 채널 구조를 갖는 Recess Channel Array Transistor (RCAT)로 cell transistor를 구현하였다. DRAM cell transistor에서 junction leakage current 증가는 DRAM retention time 열화에 심각한 영향을 미치는 요인으로 알려져 있으며, DRAM의 minimum feature size가 점점 감소함에 따라 short channel effect의 영향으로 junction leakage current는 더욱 더 증가하게 된다. 본 실험에서는 short channel effect의 영향에 의한 junction leakage current를 감소시키기 위하여 Recess Channel Array Transistor를 도입하였고, cell transistor의 채널 영역을 비대칭으로 형성하여 data retention time을 증가시켰다. 비대칭 채널 구조을 이용하여 Recess Channel Array Transistor를 구현한 결과, sub-threshold 특성과 문턱전압, Body effect, 그리고, GIDL 특성에는 큰 유의차가 보이지 않았고, I-V특성인 드레인 포화전류(IDS)는 대칭 채널 구조인 transistor 대비 24.8% 정도 증가하였다. 그리고, data retention time은 2배 정도 증가하였다. 본 실험에서 얻은 결과는 향후 저전압 DRAM 개발과 응용에 상당한 기여를 할 것으로 기대된다.

  • PDF

실리콘 광증폭기와 반응깊이 측정방법을 이용한 수술용 베타 영상/감마 프로브 가능성 연구 (A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement)

  • 곽인석;강한규;손정환;이재성;홍성종
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.7-14
    • /
    • 2016
  • Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).

공군 전투조종사 비행복 착용특성 및 만족도 조사 (Research on Actual Usage and Satisfaction of ROKAF Fighter Pilot's Flight Duty Uniform)

  • 이아람;남윤자;홍유화;임소정;임채근
    • 한국의류학회지
    • /
    • 제40권4호
    • /
    • pp.669-684
    • /
    • 2016
  • This study investigates Korean fighter pilot's usage and satisfaction of a flight duty uniform (FDU). The survey was conducted from October 2014 to March 2015 using Focus Group Interview (FGI) and questionnaires. FGI collected qualitative data about duty and requirements; subsequently, surveys were performed to collect quantitative data about wearing conditions and satisfaction with FDU. The results of the FGI and the questionnaire were as follows. Type of pilot duty was divided into two parts, flight duty and ground duty. It is important to consider duties as well as factors related to survival when developing FDU. According to anthropometric data and wearing size, the basic size for apparel grading should be changed from actual size, 'M95XL' to 'M100L'. It is also necessary to improve the whole sizing system. Further studies about body form changes in pilot's movement are needed to improve mobility because the respondents perceived some restrictions at several body parts in movement with the coverall uniform. Summer FDU had a low satisfaction level in vent hole function and appearance. Furthermore, protection problems in the vent hole were also an issue. Making a seasonal classification of FDU fabric will be more effective than a vent hole to increase a pilot's thermal satisfaction. Respondents had a passive stance towards FDU reform (including pocket change); therefore, a new FDU design strategy should concentrate on improving current FDU functions like mobility (or comfort) rather than dramatic changes. Pilots complained about the quality stability of FDU; therefore, quality control by military administration as well as concrete and clear design instructions by the developer should be attained together. The results obtained in this study are expected to be used as an important basis for the further development of FDU.

64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가 (Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography)

  • 성열훈;김영옥;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.137-144
    • /
    • 2010
  • 64 multi-detector computed tomography (MDCT)에서 두개부의 과도한 선량이 문제가 되어 고정관류기법과 관전류 자동노출조절(automatic exposure control, AEC) 기법을 이용하여 선량 감소 정도를 비교 평가하고자 한다. 연구에 사용한 장비는 Siemens사의 SOMATOM Definition 64 multi-detector CT를 이용했으며, Whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd)의 두개부를 사용했다. 실험 protocol은 helical scan 방식을 적용하여 120 kVp, rotation time은 1 sec, slice thickness와 increment는 각각 5 mm, FOV는 250 mm, matrix size는 $512{\times}512$, collimation은 $64{\times}0.625\;mm$, pitch는 1로 조사하였다. 선량감소효과의 측정방법은 관전류를 350 mAs로 고정한 방법과 AEC 기법을 적용한 방법으로 나누어 평가하였으며, 영상품질은 CT number의 표준편차를 이용하여 영상의 잡음을 측정하였다. 이 때 두개부(craniofacial bone)는 머리덮개뼈(calvaria) 끝부분에서 눈썹활(superciliary ridge)까지를 1구역, 논썹활 아래부터 코가시점(acanthion)까지를 2구역, 그리고 코가시점 아래부터 턱(mentum)끝까지를 3구역으로 정의하여 측정하였다. 고정관류기법에서 구역별로 CTDIvol은 57.7 mGy였으며, DLP는 $640.2\;mGy{\cdot}cm$로 동일하였다. AEC 기법을 적용한 1구역은 CTDIvol: 30.7 mGy, DLP: $340.7\;mGy{\cdot}cm$, 2구역은 CTDIvol: 46.5 mGy, DLP: $515.0\;mGy{\cdot}cm$, 그리고 3구역은 CTDIvol: 30.3 mGy, DLP: $337.0\;mGy{\cdot}cm$으로 나타났다. 영상품질을 나타내는 CT number의 표준편차는 1구역에서 고정 관류기법은 2.6, AEC 기법은 3.0, 2구역에서 고정 관류기법은 3.1, AEC 기법은 3.4, 3구역에서 고정 관류기법은 2.7, AEC 기법은 3.2으로 측정되었다. 64 MDCT에서의 AEC 기법은 기존의 고정관류법에 비해 안구, 이하선 그리고 갑상선 부위에 대해 큰 선량 감소효과가 나타났으며, 두개부의 방사선량을 감소시키는데 매우 유용한 기법으로 사료된다.

Year-to-Year and Inter-Decadal Fluctuations in Abundance of Pelagic Fish Populations in Relation to Climate-Induced Oceanic Conditions

  • Gong, Yeong;Suh, Young-Sang;Han, In-Seong;Seong, Ki-Tack
    • Journal of Ecology and Environment
    • /
    • 제31권1호
    • /
    • pp.45-67
    • /
    • 2008
  • Ocean climate variables ($1900{\sim}2005$), time series of catches ($1910{\sim}2005$) and body size data were used to assess the year-to-year and decadal scale fluctuations in abundance of the fish populations (Japanese sardine, anchovy, jack mackerel, chub mackerel, Pacific saury and common squid) that have spawning grounds in the East China Sea and its adjacent regions. A negative correlation between the abundance of pelagic fishes (e.g. jack mackerel) in the Tsushima Warm Current (TWC) region and the Kuroshio-Oyashio Current (KOC) region was attributed to the climatic modulation of larval transport and recruitment, which depends on the winter monsoon-induced drift, current systems, and spawning season and site. The changes in abundance and alternation of dominant fish populations in the two regions in the 1930s, 1970s, and late 1980s mirrored changes in the climate indices (ALPI, AOI and MOI). Oscillations in the decadal climate shifts between the two regions led to zonal differences in larval transport and recruitment, and hence differences in the abundance of the pelagic fish populations. During deep Aleutian Lows, as in the 1980s, larval transport from the East China Sea to the KOC region increases in association with the strong winter Asian monsoon, cool regime and increased volume transport of the Kuroshio Current systems, whereas during a weak Aleutian Low (as in the 1990s), larval transport to the TWC region increased in association with a weak winter Asian monsoon, a warm regime, and increased volume transport of the Tsushima current system. We postulate that the increased chub mackerel abundance in the TWC region and the decreased abundance in the KOC region in the 1990s are partly attributed to changes in recruitment and availability to the fishing fleets under the warm regime in the spawning and nursery grounds in the East China Sea in association with the quasi-steady state of mild winter monsoon in the 1990s. The fluctuations in chub mackerel and jack mackerel abundance are under the environment-dependant growth form, although the tropicalization was identified in the TWC region. The density-dependant growth form was found in Japanese sardine populations, but no tropicalization by fishing was identified in the long ($10{\sim}15$ year) periods of abundance despite their short ($3{\sim}4$ year) generation time, suggesting that the environment-dependant growth form drove the changes in abundance. Year-to-year and decadal scale variations in abundance and population structure of the Pacific saury responded to climate regime shifts (1976/1977, 1988/1989), suggesting that the fish is a key bio-indicators for changes in the ecosystem.

전원전압 1.0V 산소 및 과산화수소 기반의 정전압분극장치 설계 (Design of 1.0V O2 and H2O2 based Potentiostat)

  • 김재덕;;최성열;김영석
    • 한국정보통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.345-352
    • /
    • 2017
  • 본 논문에서는 전원전압 1V에서 동작하는 산소 및 과산화수소 기반의 혈당전류를 측정할 수 있는 통합형 정전압분극장치를 설계하고 제작하였다. 정전압분극장치는 저전압 OTA, 캐스코드 전류거울 그리고 모드 선택회로로 구성되어 있다. 정전압분극장치는 산소 및 과산화수소 기반에서 혈당의 화학반응으로 발생하는 전류를 측정할 수 있다. OTA의 PMOS 차동 입력단의 바디에는 순방향전압을 인가하여 문턱전압을 낮추어 낮은 전원전압이 가능하도록 하였다. 또한 채널길이변조효과로 인한 전류의 오차를 줄이기 위해 캐스코드 전류거울이 사용되었다. 제안한 저전압 정전압분극장치는 Cadence SPECTRE를 이용하여 설계하였으며, 매그나칩 $0.18{\mu}m$ CMOS 공정을 이용하여 제작되었으며 회로의 크기는 $110{\mu}m{\times}60{\mu}m$이다. 전원전압 1.0V에서 소모전류는 최대 $46{\mu}A$이다. 페리시안화칼륨($K_3Fe(CN)_6$)을 사용하여 제작된 정전압분극장치의 성능을 확인하였다.