Synthesis of Bi-Sb-Te Thermoelectric Nanopowder by the Plasma Arc Discharge Process (플라즈마 아크 방전법에 의한 Bi-Sb-Te 나노 열전분말 제조)

  • Lee, Gil-Geun;Lee, Dong-Youl;Ha, Gook-Hyun
    • Journal of Powder Materials
    • /
    • v.15 no.5
    • /
    • pp.352-358
    • /
    • 2008
  • The present study focused on the synthesis of a bismuth-antimony-tellurium-based thermoelectric nanopowders using plasma arc discharge process. The chemical composition, phase structure, particle size of the synthesized powders under various synthesis conditions were analyzed using XRF, XRD and SEM. The powders as synthesized were sintered by the plasma activated sintering. The thermoelectric properties of sintered body were analyzed by measuring Seebeck coefficient, specific electric resistivity and thermal conductivity. The chemical composition of the synthesized Bi-Sb-Te-based powders approached that of the raw material with an increasing DC current of the are plasma. The synthesized Bi-Sb-Te-based powder consist of a mixed phase structure of the $Bi_{0.5}Sb_{1.5}Te_{3}$, $Bi_{2}Te_{3}$ and $Sb_{2}Te_{3}$ phases. This powder has homogeneous mixing state of two different particles in an average particle size; about 100nm and about 500nm. The figure of merit of the sintered body of the synthesized 18.75 wt.%Bi-24.68 wt.%Sb-56.57 wt.%Te nanopowder showed higher value than one of the sintered body of the mechanically milled 12.64 wt.%Bi-29.47 wt.%Sb-57.89 wt.%Te powder.

Fundamental research for the development of personal protective equipment for emergency medical technicians (구급대원용 개인보호복 개발을 위한 기초연구)

  • No, Yoo-Min;Nam, Yun-Ja;Lee, Hye-Rin;Kim, Tae-Han;Kim, Chu-Hyun;Shin, Sang-Do
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.83-97
    • /
    • 2018
  • Purpose: The purpose of this study was to provide basic data for the development of personal protective equipment (PPE) for emergency medical technicians (EMTs) during chemical, biological, radiological, nuclear, and explosive situations. Methods: Body measurements were obtained for adults aged from 20 to 59 years from the data in the 6 th Size Korea national sizing survey. These data were compared to the sizes of protective clothing currently available in the market. In-depth interviews with active paramedics with experiences of wearing PPE were conducted. Results: Most of the imported protective clothing turned out to be unfit for Korean adults. This showed the urgent need for developing appropriately sized protective clothing for Korean emergency technicians. In total, 55.0% of the respondents indicated that the current protective clothing is unsafe, and 71.0% requested the clothing to have level C protective performance. Regarding the design, many people wanted hooded all-in-one type of clothing. Conclusion: Considering these requirements, most of the wearers wanted their protective clothing to be fundamentally protective of their body, be available in various sizes with adjustable parts, and easy to wear and take off. They also wanted the clothing to be secure in clear sight, while not revealing any parts of their body and not interfringe with their ability to communicate with others.

A Study on Pendulum Generator Using Human Body Kinetic Energy (인체 운동 에너지를 이용한 진자 발전기에 관한 연구)

  • Jee, In-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.117-122
    • /
    • 2022
  • In this study, Electromagnetic Induction Power Generation (EMG) is a structure consisting of a stator and a permanent magnet rotor, and is a method that enables power generation by using the kinetic energy of the human arm. Among them, the axial flux permanent magnet (AFPM) technique is a method that can act sensitively to the kinetic energy of the arm at a slow speed of the human body, and has a simple structure and can be designed and manufactured with an ultra-small size. Under the conditions of size of ø46×11mm, rotation speed of 7Hz (420rpm), output voltage 0.4VAC, output current 4.5mA, and output power 30mW were measured and analyzed the same as the target specification. Therefore, the purpose of this study is to study the power generation of the pendulum applying the AFPM (Axial Flux Permanent Magnet) technique to charge power to smart devices with kinetic energy of the human body.

A Study on the Korean Costume Pattern Design Using CAD System(I) -With Concentration on the Girl's Color-Strip Blouse & Skirt- (CAD SYSTEM을 이용한 한복의 기성복 설계에 관한 연구(I) -여아 색\ulcorner 저고리 및 치마를 중심으로-)

  • 조영아
    • Journal of the Korean Society of Costume
    • /
    • v.19
    • /
    • pp.105-125
    • /
    • 1992
  • The research, aiming an automatic pattern design of Korean Costume by utilizing CAD system, tried Grading, Seaming and Marking with a theme of girl's color-strip blouse & skirt. The content & conclusion of the research can be outlined as follows; 1) As we reviewed the current situation of Korean costume which becomes more likely celebrational or festival costume, while the demand of it is getting increase, it's being dealt mostly as ready-made dresses with different qualities & designs. Especially childrens ready-made ones were highly demanded to be picked up as the theme. 2) For the original drawing of children's color-strip blouse & skirt, Kyung-Ja Park's drawing method was used here, and for the substitute of particular body parts absolute size, Joo-Won Lee's standard size chart from a size-study by ages. 3) To work with CAD system we had input master pattern, drawn for age 5 as basic size, then graded six step-sizes for 1-11 years old. For add-subtract of particular body parts size, we graded through computing the standard variation among items to get the pattern developed into ready-made standard size, we can make precise plotting by grading wanted size very rapidly if we correct the rule of changed items different from standard size to make utilization possible enough with easy order method of ready-made Korean Dress. 4) We produced Marker after attaching a margin to seam accordingly by parts for each pattern using P/D/S to mark, In mass gament-cutting, the loss of time and material can minimized. In this research the apparel CAD system which has been utilized and only be western fashion industry was introduced for the design of ready-made Korean costume and utilized it in Grading, Marking which are critical steps to improve productivity and have reported the result in the research. Thus we expect that less cost, improved productivity and better quality with minimized loss of material from marking as well as from prompt and precise size-drawing. Furthermore the utilization of CAD system is considered as an effective one in terms of the research & the development to remove effective one in terms of the research & the development to remove irrational elements in the design and production process of Korean costume as well as in terms of the study of Korean Costume development through creative works of Korean Costume.

  • PDF

Diet and Health-Related Factors of the Middle-Aged and the Elderly in Korea

  • Park, Seon-Joo;Lee, Hae-Jeung;Kim, Jung-Hee;Kim, Cho-Il;Chang, Kyung-Ja;Yim, Kyeong-Sook;Kim, Kyungwon;Park, Haymie
    • Journal of Community Nutrition
    • /
    • v.4 no.1
    • /
    • pp.29-37
    • /
    • 2002
  • This study was designed to assess diet and health-related factors of older adults in Korea. Subjects females were 2,660 adults aged 50 and over living in Korea. Males were 847 persons and were 1813 persons. The mean weight and height for males and females were 63.8 $\pm$ 0.3kg / 164.0 $\pm$ 0.2cm and 57.0 $\pm$ 0.2kg /150.6 $\pm$ 0.1cm respectively. BMI (body mass index), body fat, and percent fat were significantly greater in females than in males. The muscle mass and body water were significantly greater in males than in females. Twenty-one percent of total subjects lived alone and 26% with spouse only. Most of the subject's self-reported income was in middle level (65%) or low level (24%). Proportion of subjects who answered 'very poor' or 'poor' on perceived health status was higher in older group. The 50-64 years old group was facing more stress than 65yr and over group. Among male subjects,38.4% were current-smokers and 22.0% were ex-smokers. But only 6.5% of female subjects were current-smokers. Males turned out to have better dietary habits-meal frequency per day, mealtime regularity, regular meal size and balanced eating-than females (p < 0.001). This study revealed that the diet and health-related factors affect nutritional status and chronic diseases of the elderly. For better management and evaluation of health status of the elderly, more effective nutritional assessment tools should be developed.

Foreign Body Ingestion in Children: Should Button Batteries in the Stomach Be Urgently Removed?

  • Lee, Jun Hee;Lee, Jee Hoo;Shim, Jung Ok;Lee, Jung Hwa;Eun, Baik-Lin;Yoo, Kee Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.1
    • /
    • pp.20-28
    • /
    • 2016
  • Purpose: Foreign body (FB) ingestion is common in children, and button battery (BB) ingestion has been increasing in recent years. This study was to identify factors related to outcomes of FB ingestion, particularly BBs in the stomach. We evaluated whether the current recommendations are appropriate and aimed to suggest indications for endoscopic removal of BB in the stomach in young children. Methods: We investigated patient age, shape, size, location of FBs, spontaneous passage time and resulting complications among 76 children. We observed types, size, location of BB and outcomes, and analyzed their associations with complications. Results: Coins and BB were the two most common FBs. Their shapes and sizes were not associated with the spontaneous passage time. Size, spontaneous passage time, and age were also not associated with any specific complications. For BB ingestion, all 5 cases with lithium batteries (${\geq}1.5cm$, 3 V) presented moderate to major complications in the esophagus and stomach without any symptoms, even when the batteries were in the stomach and beyond the duodenum, while no complications were noted in 7 cases with alkaline batteries (<1.5 cm, 1.5 V) (p=0.001). All endoscopies were conducted within 24 hours after ingestion. Conclusion: The type and voltage of the battery should be considered when determining whether endoscopy is required to remove a BB in the stomach. For lithium battery ingestion in young children, urgent endoscopic removal might be important in order to prevent complications, even if the child is asymptomatic and the battery is smaller than 2 cm.

Effect of extrusion of soybean meal on feed spectroscopic molecular structures and on performance, blood metabolites and nutrient digestibility of Holstein dairy calves

  • Berenti, Ammar Mollaei;Yari, Mojtaba;Khalaji, Saeed;Hedayati, Mahdi;Akbarian, Amin;Yu, Peiqiang
    • Animal Bioscience
    • /
    • v.34 no.5
    • /
    • pp.855-866
    • /
    • 2021
  • Objective: Performance and physiological responses of dairy calves may change by using extruded soybean meal (ESBM) instead of common soybean meal (SBM) in starter feed. The aims of the current study were i) to determine the effect of extrusion processing of SBM on protein electrophoretic size, fourier transform infrared spectroscopy (FTIR) structures and Cornell Net Carbohydrate and Protein System (CNCPS) protein subfractions and ii) to determine the effect of substitution of SBM with ESBM in starter feed of Holstein heifer calves during pre and post-weaning on performance, nutrient digestibility, and blood metabolites. Methods: The SBM was substituted with ESBM at the level of 0%, 25%, 50%, 75%, and 100% (dry matter [DM] basis). Fifty heifer calves (initial body weight 40.3±0.63 kg) were used for the study. After birth, animals were fed colostrum for 3 days and then they were fed whole milk until weaning. Animals had free access to starter feed and water during the study. Results: Extrusion of SBM decreased electrophoretic protein size and increased rapidly degradable true protein fraction, changed FTIR protein and amide II region. With increasing level of ESBM in the diet, starter intake increased quadratically during the pre-weaning period (p<0.05) and body weight, DM intake and average daily gain increased linearly during the post-weaning and the whole study period (p<0.05). Tbe DM and crude protein digestibilities at week 14 and blood glucose and beta hydroxybutyric acid increased linearly in calves as the level of ESBM increased in the diet (p<0.05). Conclusion: Dairy calves performance and physiological responses were sensitive to SBM protein characteristics including electrophoretic size, FTIR structures and CNCPS protein fractions.

Identification of the Minimum Legible Text Size for Group-View Display of the Main Control Room in Radioactive Waste Facility

  • Jung, Kihyo;Lee, Baekhee;Chang, Yoon;Jung, Ilho;You, Heecheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.213-219
    • /
    • 2017
  • Objective: The present study identified the minimum legible text size by an experiment for eight combinations of background and text colors, which will be used in designing visual information on group-view display (GVD). Background: Information on minimum legible text size is needed to design the visual information presented on GVD in a radioactive waste control room. Method: The experiment was conducted for 22 male participants (age: mean = 37, SD = 6.7; visual acuity: over 0.8) who were recruited by considering demographic characteristics of current control room operators. Eight combinations of background and text colors were considered and the minimum legible text size was determined for each combination by applying the method of limits, one of psychophysical methods. Results: The minimum legible text size was significantly different in accordance with the combination of background and text colors. Statistical analysis results showed that luminance contrast and color contrast between background and text influenced the minimum legible text sizes. Conclusion: This study concluded that the minimum legible text size is 8 minute of arc for various combinations of background and text colors. Application: The minimum legible text size identified in the present study can be utilized in designing visual information on GVD at the main control room in a radioactive waste facility.

Wireless Communication Systems for Human Implantable Artificial Cochlea (인체 삽입형 인공와우를 위한 무선 통신 시스템)

  • Han, Sungmin;Shin, Jaesub;Cho, Jaewook;Jang, Jongmoon;Choi, Hongsoo;Choi, Ji-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1150-1158
    • /
    • 2013
  • Artificial cochlear implant system is known as the most efficient and widespread device to patients who have cochlear disorder. However, current commercialized artificial cochleas have inconveniences because of large volume size and high power consumption, requiring further research on improvements in terms of the size, power, and performance. In this paper, we will introduce our fully implantable artificial cochlear implant system, where small-size sensors and actuators are wirelessly connected, focusing on communication system design and its performance simulation.

Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti (입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동)

  • Lee Seung-Woo;Kim Yun-Jong;Ruy Jae-Gyeoung;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.