• Title/Summary/Keyword: current body image

Search Result 120, Processing Time 0.032 seconds

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF

A Study on Cinematic Representations of Posthuman Girls in South Korea-Focused on The Silenced and The Witch: Part 1. The Subversion (한국 영화에 나타난 포스트휴먼 소녀의 재현 양상 연구 -<경성학교: 사라진 소녀들>, <마녀>를 중심으로)

  • Kim, Eun Joung
    • Journal of Popular Narrative
    • /
    • v.27 no.3
    • /
    • pp.95-124
    • /
    • 2021
  • As the symbolic images of girls besides its definition have varied according to the age and society, a posthuman girl character recently appears in the digital cinema. This study aims to analyze its cinematic representations and the social contexts in which they are created. For this purpose, the study focuses on what extent the society allows its imagined figurations as a future female body and the meanings revolving around the image of 'technologically body-enhanced female fighter'. Current digital visualization technology has developed to the extent any imaged future humans can be represented, but posthuman girls' representations have its limitation that only a human-like figuration can be allowed in accord with the traditionally idolized image of girls. It is because of the representation logic in which digital cinema is visualized based on perceptual realism that values audiences' experiences. Despite such less critical figuration which does not dare to cross the boundary between the image of human and inhuman, the posthuman girl characters create a new category of the 'dangerous girls' who are both void of sexual femininity and independent of motherhood and heterosexual romance narrative. Of course, they support the modern human-centered belief that humans can take entire control of technology with their moral behaviors and dispel the fear about the negative impact the nature of technology may have on society at large by showing their child-like figuration protecting ethical values. However, the new character of 'unruly girl' exerts her subversive act that seeks to fight against the human-centered liberal humanistic values and melancholic feeling and vulnerability that the neoliberalism and technocracy enforce. When posthuman girl characters are considered to be a marker through which we can see how different social forces are intervening and competing each other in the upcoming posthuman age, the limited figuration of the posthuman girl characters in South Korean movies illustrates the opinionated thoughts toward the instrumentalism in technology but their bloodshed struggles reveal how the corporate or state-governed techno-biopower has oppressively treated and appropriated the human body as the technology-object and also provide a meaningful opportunity to rethink its unethical violence.

The Study about Improvement of Neuro Energy Decreased by Energy Saving (에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구)

  • Kim, Myung-Ho;Kang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.715-721
    • /
    • 2018
  • This study examined energy saving and elevating the worker's neuro energy (comfort, concentration, physical, and psychological stability) by compensating for the unpleasant tactile sensation to stimulate auditory and olfactory senses and reduce energy consumption. The experiment was conducted in an environment test room under the test conditions of temperature $25[^{\circ}C]$, relative humidity 50[RH%], illumination 1,000[lux] and air current speed 0.02[m/sec] by stimulating the auditory senses with a 1/f change in rhythm and the olfactory senses with an aroma scent. The experiment utilized the method of EEG, which evaluates human body's psychological status via tactile means, and the method of the vibra image, which evaluates the learning abilities, HRV and human body's psychological status via non-tactile means. The subjects were selected as eight university students (four males and four females) in their 20s, the type that have high relative ${\alpha}$(8~13[Hz]) activation in occipital lobe, which brings the highest level of mind stability and concentration, who had no difficulty in physical activities. The subjects' posture and physical activity was fixed to 1met - when the subjects are seated and relaxing in a comfortable environment - and their clothes condition was standardized as 0.7clo. As a result, the sentimental and psychological stability and concentration were the highest in the multisensory stimulation of jasmine scent and change rhythm of an a=1.106 sound source. In addition, under this condition, the relative $M{\alpha}$ and relative $M{\beta}$ increased by 70.49[%] and 89.72[%], respectively; the HRT decreased by 39.09[%]; and the fatigue and tension/anxiety decreased by 36.85[%] and 15.54[%], respectively.

Quality of Life and Psychological Well-Being of Breast Cancer Survivors in Jordan

  • Abu-Helalah, Munir;Al-Hanaqta, Motasem;Alshraideh, Hussam;Abdulbaqi, Nada;Hijazeen, Jameel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5927-5936
    • /
    • 2014
  • Introduction: Breast cancer is the most common cancer among Jordanians. Breast cancer patients suffer from several negative consequences after treatment and these include pain, fatigue, sexual problems, appearance and body image concerns, with psychological dysfunction. This could affect the patient quality of life and psychological well-being. To the best of our knowledge, there is no published quantitative data on the quality of life and psychological well-being of breast cancer patients in Jordan. The objective of this study was to obtain such data and assess predictors with calculated scores. Methods: In this cross-sectional study conducted among breast cancer patients in Jordan diagnosed in 2009 and 2010, assessment was performed using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30), the Breast Module (QLQ-BR23) and the Hospital Anxiety and Depression Scale (HADS). Clinical, demographic and psychosocial indicators that could predict patient quality of life scores were collected. Results: The number of patients interviewed was 236 (mean age=$50.7{\pm}10.7$ years). The mean Global Health score for the QLQ-C30 was $63.7{\pm}20.2$ SD. Among functional scales, "social functioning" scored the highest ($mean=78.1{\pm}28.6$ SD), whereas "emotional functioning" scored the lowest ($mean=59.0{\pm}SD\;33.5$). For the QLQ-BR23, the worst scores within the functional scales were for "body image" ($mean=52.1{\pm}36.8$ SD) and "future perspective" ($mean=52.9{\pm}38.5$ SD). The worst symptom was "upset by hair loss" ($mean=69.8{\pm}43.0$). The mean HADS scores was $18.{\pm}9.0$ SD. Out of study participants, 53% scored abnormal on the anxiety scale and 45% on the depression scale. Severe depression and severe anxiety were detected among 8% and 14% of study participants, respectively. Statistically significant predictors for individual scores were similar to those reported in published studies, such as the presence of recurrence since baseline, family history of cancer, low educational status, current social problems, extent of the disease, presence of financial difficulties, and employment status. Conclusions and Recommendations: Breast cancer survivors in Jordan have overall good quality of life scores when compared with patients from Western countries. However, their psychological wellbeing is more impaired. There is an urgent need for psychosocial support programs and psychological screening and consultation for breast cancer patients at hospitals of the Ministry of Health in Jordan.

Research on Cross-border Practice and Communication of Dance Art in the New Media Environment (뉴미디어 환경에서 무용예술의 크로스오버 실현과 전파에 대한 연구)

  • Zhang, Mengni;Zhang, Yi
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.1
    • /
    • pp.47-57
    • /
    • 2019
  • The end of the 20th century, along with the popularity of new media technology and the rise of new media art, dance as a visual art, and body language art, has the features of more and more rich and changeful. In today's Internet booming new media environment, many different fields, such as film and theater, computer technology, digital art, etc.) with its commonness and characteristics of all kinds of interaction between the creation, produced a new interdisciplinary research with theoretical model. When cross-border interactions between various areas become a hot topic at the same time, the traditional form of dance performances are also seeking new breakthrough. Canada's famous social psychologist McLuhan believes that modern is retrieving lost over a long period of time "overall" feel, return to a feeling of equilibrium. The audience how to have the characteristics of focus on details of visual art back to the "overall" feel worthy of study. At the same time, the new media in today's digital dance teaching in colleges and universities dancing education remains to be perfect and popular, if continue to use the precept of the traditional teaching way blindly, so it is difficult to get from the development of the current domestic dance overall demand. In this paper, the main body is divided into two parts, the first chapter is the study of image device dance performance art, the second chapter is the research of digital dance teaching application system, thus further perspective of media technology to explore dance art crossover practice under the new media environment and mode of transmission.

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Primary Malignant Melanoma in the Pineal Region

  • Park, Jae-Hyun;Hong, Yong-Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.6
    • /
    • pp.504-508
    • /
    • 2014
  • A 59-year-old male patient had 5-month history of gait disturbance and memory impairment. His initial brain computed tomography scan showed $3.5{\times}2.8cm$ sized mass with high density in the pineal region. The tumor was hypointense on T2 weighted magnetic resonance images and hyperintense on T1 weighted magnetic resonance images with heterogenous enhancement of central portion. The tumor was totally removed via the occipital transtentorial approach. Black mass was observed in the operation field, and after surgery, histopathological examination confirmed the diagnosis of malignant melanoma. Whole spine magnetic resonance images and whole body 18-fluoro-deoxyglucose positron emission tomography could not demonstrate the primary site of this melanoma. Scrupulous physical examination of his skin and mucosa was done and dark pigmented lesion on his left leg was found, but additional studies including magnetic resonance images and skin biopsy showed negative finding. As a result, final diagnosis of primary pineal malignant melanoma was made. He underwent treatment with the whole brain radiotherapy and extended local boost irradiation without chemotherapy. His preoperative symptoms were disappeared, and no other specific neurological deficits were founded. His follow-up image studies showed no recurrence or distant metastasis until 26 weeks after surgery. Primary pineal malignant melanomas are extremely rare intracranial tumors, and only 17 cases have been reported since 1899. The most recent case report showed favorable outcome by subtotal tumor resection followed by whole brain and extended local irradiation without chemotherapy. Our case is another result to prove that total tumor resection with radiotherapy can be the current optimal treatment for primary malignant melanoma in the pineal region.

SPECTROSCOPIC AND PHOTOMETRIC STUDY OF STARBURST GALAXIES: OPTICAL AND NEAR INFRARED PROPERTIES OF A BLUE COMPACT DWARF GALAXY MRK 49 IN THE VIRGO CLUSTER

  • Sung, Eon-Chang;Kyeong, Jae-Mann;Byun, Yong-Ik
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.5
    • /
    • pp.121-137
    • /
    • 2008
  • We present optical and near-infrared imaging and long-slit spectroscopy for the blue compact dwarf galaxy (BCD) Mrk 49 in the Virgo Cluster. The surface brightness distribution analysis shows that Mrk 49 consists of an off-centered blue bright compact core of r = 10" and a red faint outer exponential envelope. The $H_{\alpha}$ image and color difference suggest that these two components have different stellar populations: a high surface brightness population of massive young stars and an underlying low surface brightness population of older stars. The redder near-infrared colors of the inner most region suggest that the near-infrared flux of Mrk 49 originates from evolved massive stars associated with the current star-forming activity. The total apparent magnitude is $B_T\;=\;14.32$ mag and the mean effective surface brightness is ${\mu}_{eff}(B)\;=\;21.56$ mag $arcsec^{-2}$. Long-slit spectroscopy shows that Mrk 49 rotates apparently as a solid body within r = 10" in a plane at position angle 55 degrees with an amplitude of about $20\;km\;sec^{-1}$. The measured radial velocity of Mrk 49 was derived as $1,535\;km\;sec^{-1}$; and the total mass of stars and gases is in the range of 3 to $6\;{\times}\;10^9\;M_{\odot}$. The mass-to-light ratios for the central region of Mrk 49 in I and B band are estimated 1.0 and 0.5, respectively. The upper limit of the dark matter to visible matter ratio seems to be < 5. The oxygen abundance is $12\;+\;\log(O/H)\;=\;8.21\;{\pm}\; 0.1$ which is about one quarter of the solar value while the relative helium abundance appears to be similar to that of the sun.