DOI QR코드

DOI QR Code

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals

CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구

  • Jeong, Cheon-Soo (Yedamdental Hospital) ;
  • Mo, Eun-Hee (Department of Radiation Science & Technology, Chonbuk University) ;
  • Lee, Gee-Heun (Department of Radiation Science & Technology, Chonbuk University) ;
  • Han, Beom-Hee (Department of Radiological Science, Seonam University) ;
  • Kim, Seung-Chul (Department of Radiological Science, Songho College) ;
  • Kim, Jung-Sam (Department of Radiological Science, Mokpo science University) ;
  • Lim, Cheong-Hwan (Department of Radiological Science, Hanseo University)
  • 정천수 (예닮치과병원) ;
  • 모은희 (전북대학교 방사선과학기술학과) ;
  • 이기흔 (전북대학교 방사선과학기술학과) ;
  • 한범희 (서남대학교 방사선학과) ;
  • 김승철 (송호대학교 방사선과) ;
  • 김정삼 (목포과학대학교 방사선과) ;
  • 임청환 (한서대학교 방사선학과)
  • Received : 2011.09.09
  • Accepted : 2011.12.22
  • Published : 2011.12.30

Abstract

In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

치과 방사선 검사 중 파노라마(panorama) 촬영은 왜곡현상이 발생하여 정량적인 평가 시 부정확한 결과를 야기할 수 있다. 최근 임상에 적용되고 있는 새로운 영상화 기법인 cone beam형 전산화단층촬영(이하 CBCT)은 고해상도의 영상과 위치 정보를 제공한다. 본 실험에서는 DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea)을 사용하여 20명의 환자를 검사하였고, 촬영조건은 관전압 85kVp, 관전류 7mA, 촬영시간은 24초이다. CBCT 데이터를 3차원 컴퓨터 프로그램을 이용하여 재구성하고, 형태 계측학적으로 평가 분석하였다. 그 결과 하악체에 기울기에 따라 변화를 주었을 때, 하악관의 직경의 왜곡이 감소하는 것을 알 수 있었다. 결론적으로 피사체와 필름간의 거리가 클수록 확대가 많이 나타나고, 초점에서 벗어난 거리에 따라 영상이 차이가 있을 것으로 예상되기 때문에 재구성시 해부학적 위치의 구조에 맞게 부분적으로 알맞은 방법을 채택을 해야 하는 것으로 사료된다.

Keywords

References

  1. 권대철․동경래․정재은․ 외., "파노라마 촬영의 피폭선량에 관한 문헌분석 연구", 방사선기술과학, Vol. 33, No. 1, pp.1-2, 2010.
  2. 선민규․엄기수․조진형․황현식, "3차원 콘빔CT영상에 형성한 2차원 정모두부방사선사진영상의 정확도 증진을 위한 두부자세재현기의 효과, Korean J Orthod, Vol. 39, pp.289-299, 2009. https://doi.org/10.4041/kjod.2009.39.5.289
  3. De Vos W, Casselman J, Swennen GR, "Cone-beam computerized tomography(CBCT) imaging of the oral and maxillofacial region: a sdystematic review of the literature, Int J Oral Maxillofac Surg, Vol. 38, pp.609-625, 2009. https://doi.org/10.1016/j.ijom.2009.02.028
  4. 한우리, "치과용 콘빔 CT 영상에서 측정한 이공관의 위치", 석사학위논문, pp.9-10, 2009.
  5. Choi YS, Hwang HE, Lss SR, "Clinical application of cone beam computed tomography in dental implant", J Korean Dent Assoc, Vol. 44, pp.172-179, 2006.
  6. Pinsky HM, Dydal S, Pinsky RW, Misch KA, Sarment DP, "Accuracy of three-dimensional measurements using cone-beam CT, Dentomaxillofac Radiol, Vol. 35, pp.410-416, 2006. https://doi.org/10.1259/dmfr/20987648
  7. 최영석, 김규태, 황의환, "Cone beam형 전산화단층영상의 원리", 대한구강악안면방사선학회지, Vol. 36, pp.128, 2006.
  8. Baba R, Ueda K, Okabe M, "Using a flat-panel detector in high resolution cone beam CT for dental imaging, Dentomaxillofac Radiol, Vol. 33, pp.285-290, 2004. https://doi.org/10.1259/dmfr/87440549
  9. Crawford CR, King KF, "Computed tomography scanning with simultaneous patient translation". Med Phys, Vol. 17, pp.967-982, 1990. https://doi.org/10.1118/1.596464
  10. Kalender WA, Polacin A, "Physical performance characteristics of spiral CT scanning", Med Phys, Vol. 18, pp.910-915, 1991. https://doi.org/10.1118/1.596607
  11. Hu H, "Multi slice helical CT : Scan and reconstruction", Med Phys, Vol. 26, pp.5-18, 1999. https://doi.org/10.1118/1.598470
  12. 신윤자, "Cone beam 전산화단층촬영을 이용한 하악 이공의 형태계측학적 연구", 석사학위논문, pp.14-15, 2010.
  13. 허성수, "하악골 비대칭 평가를 위한 CBCT-재구성 파노라마 영상의 응용", 석사학위논문, pp.20-21, 2010.
  14. Kambylafkas P, Murdock E, Gilda E, Tallents RH, Kyrkanides S, "Validity of panoramic radiographs for measuring mandibular asymmetry", Angle Orthod, Vol. 76, pp.388-393, 2006.
  15. Farman AG, "ALARA still applies", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, Vol. 100, pp.395-397, 2005. https://doi.org/10.1016/j.tripleo.2005.05.055

Cited by

  1. Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image vol.7, pp.4, 2013, https://doi.org/10.7742/jksr.2013.7.4.301
  2. Tooth Distortion as a Function of Arch Form in Cone Beam Computed Tomography vol.48, pp.2, 2015, https://doi.org/10.1080/00387010.2013.856325
  3. Study on accuracy of panorama and CBCT through length measurement of wisdom teeth vol.7, pp.2, 2013, https://doi.org/10.7742/jksr.2013.7.2.131
  4. Comparison of Dose Depending on the Position when Shooting Panorama and CBCT vol.7, pp.3, 2013, https://doi.org/10.7742/jksr.2013.7.3.175
  5. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device vol.72, pp.10, 2018, https://doi.org/10.3938/jkps.72.1129