• Title/Summary/Keyword: current

Search Result 77,033, Processing Time 0.113 seconds

An Analysis of Process-oriented Design in the Invited Entries of International Competition for the Master Plan of the Yongsan Park, Korea (용산공원 설계 국제공모 출품작에 나타난 프로세스적 설계 분석)

  • So, Jin;Sung, Jong-Sang;Pae, Jeong-Hann
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.2
    • /
    • pp.11-26
    • /
    • 2013
  • Designing large parks such as Yongsan Park requires the open-ended process-oriented design approach in complex layers rather than the conventional self-completed master plan method. This study aims to examine the characteristics of process-oriented design in the eight invited entries of "International Competition for the Master Plan of the Yongsan Park, Korea"(2012). For this purpose, it analyzed each entry according to three criteria: objects of process-oriented approach, time factor and its features of phasing plan, and presentation method of the process. This analysis can not only critically review the current level of the process-centered design methodology but also suggest strategic future directions for Yongsan Park. The objects of process-oriented design in the eight works were order of physical space development, restoration process of ecosystem, recovering process of publicity, and economic operation and management. Main considerations in the objects were connections to adjacent urban fabrics, links to regional green and water system, reuse of existing buildings and infrastructures in the site. The temporal criteria of the phasing plan had two aspects. One was planning a certain time and period, and the other was just establishing an order of phases. Most of the presentation method of process was the phasing plan, but some of the entries suggested a scenario plan. The eight works of "International Competition for the Master Plan of Yongsan Park" did not attempt process-oriented designs entirely and completely. Rather, they tried to introduce the phasing plan as part of a process-centered design. Also, they took an eclectic approach between master plan and process-oriented design instead of rejecting the conventional master plan approach.

A Comparison of the Overall Satisfaction of the Tourist Attractions at the Terelj Tourist Area in Mongolia by Mongolian and Korean Travelers (몽골 테렐지 관광지 관광자원 매력에 관한 몽·한 관광객 만족도 비교 분석)

  • Kim, Dong-Chan;Byambajamts, Nasanjargal
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.96-106
    • /
    • 2013
  • The aim of this study was to reveal the advantages and disadvantages of Terelj Mongolian National Park based on the impressions of foreign and domestic travelers, and subsequently suggest supporting ideas to make this tourist attraction more enjoyable for travelers. A statistical program(SPSS 20.0) and an IPA matrix method were used to reveal the impressions of travelers and the results showed the following ideas. First, we made the technical analyses to demonstrate the characteristics of the current natural scenery which travelers want to see and the results indicated that both Korean and Mongolian travelers overall were not satisfied and the Park was not as they had imagined. The second part of the research highlighted the differences between the impressions held by Mongolian and Korean travelers, which showed dissimilarities in cultural resources, food, variety of events, cultural functions and parking, all of which were shown as important criteria in sightseeing. The variations were found in scenes of nature, variety of programs, and food, areas which revealed and were very important in the overall satisfaction of travelers. Third, the IPA method was used for analyze the advantages and disadvantages of Terelj National Park. The Mongolian travelers nominated the width of the road, cleanliness, variety of events and parking are the most essential things to feel satisfied, but Koreans selected safety of travel, accommodation, the width of the road and cleanliness. Finally, we analyzed the feelings of the travelers at the end of their trip. The Mongolian travelers preferred the area resource and environment convenience to feel satisfaction. For Korean travelers, the area resource is the most important when choosing travelling sights. Based on these results, if we take responsibility to protect the beauty of nature, and create a sightseeing place using natural sources, while also making more comfortable accommodations and improving the services, it can be a more unique place than others and lead to greater overall satisfaction for travelers.

Management of the Nakdong-Jeongmaek based on the Characteristics of Cold Air - Focused on Busan, Ulsan, Pohang - (찬공기 특성을 고려한 낙동정맥 관리방안 연구 - 부산, 울산, 포항 인근을 대상으로 -)

  • Eum, Jeong-Hee;Son, Jeong-Min
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.103-115
    • /
    • 2016
  • This study aims to analyze the properties of cold air production and its flow of Nakdong-Jeongmaek(mountain ranges), and to suggest management strategies for Nakdong-Jeongmaek in order to enhance the green air conditioning functions of Jeongmaek. For this purpose, three study sites including Gudeoksan Mountain and the vicinity in Busan, Goheonsan Mountain and the vicinity in Ulsan, and Unjusan Mountain and the vicinity in Pohang were selected. The results found that cold air flow and its height of the three study sites were analyzed based on topographic properties and land use. Management strategies for preserving and enhancing their temperature reduction functions were suggested. The cold air produced in the vicinity of Gudeoksan was not fully developed and spread because of the high-density development at the border of Jeongmaek. Since high pressures of development are expected at the border, high conservation policies are required. In the vicinity of Goheonsan, where the agricultural complex and industrial park are located, cold air flows well throughout the entire study site thanks to fully developed cold air in the wide, flat valley. Hence, plans to maintain the current cold air flow are required, and conservation plans to mitigate future developments are also needed in the flat valley. The cold air in Unjusan and the vicinity with its complex and narrow mountain valleys gradually develops into valley bottoms. In order to take advantage of the terrain, the valley near the cold air production areas are preserved. In particular, special plans are required to prevent damage to the cold air layer near Youngcheonho Lake, where the highest height of cold air was recorded due to the closed and lower terrain feature. This study could support the establishment of systematic management plans of Nakdong-Jeongmaek to preserve and enhance its green air conditioning functions.

Dual Codec Based Joint Bit Rate Control Scheme for Terrestrial Stereoscopic 3DTV Broadcast (지상파 스테레오스코픽 3DTV 방송을 위한 이종 부호화기 기반 합동 비트율 제어 연구)

  • Chang, Yong-Jun;Kim, Mun-Churl
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.216-225
    • /
    • 2011
  • Following the proliferation of three-dimensional video contents and displays, many terrestrial broadcasting companies have been preparing for stereoscopic 3DTV service. In terrestrial stereoscopic broadcast, it is a difficult task to code and transmit two video sequences while sustaining as high quality as 2DTV broadcast due to the limited bandwidth defined by the existing digital TV standards such as ATSC. Thus, a terrestrial 3DTV broadcasting with a heterogeneous video codec system, where the left image and right images are based on MPEG-2 and H.264/AVC, respectively, is considered in order to achieve both high quality broadcasting service and compatibility for the existing 2DTV viewers. Without significant change in the current terrestrial broadcasting systems, we propose a joint rate control scheme for stereoscopic 3DTV service based on the heterogeneous dual codec systems. The proposed joint rate control scheme applies to the MPEG-2 encoder a quadratic rate-quantization model which is adopted in the H.264/AVC. Then the controller is designed for the sum of the left and right bitstreams to meet the bandwidth requirement of broadcasting standards while the sum of image distortions is minimized by adjusting quantization parameter obtained from the proposed optimization scheme. Besides, we consider a condition on maintaining quality difference between the left and right images around a desired level in the optimization in order to mitigate negative effects on human visual system. Experimental results demonstrate that the proposed bit rate control scheme outperforms the rate control method where each video coding standard uses its own bit rate control algorithm independently in terms of the increase in PSNR by 2.02%, the decrease in the average absolute quality difference by 77.6% and the reduction in the variance of the quality difference by 74.38%.

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

Ecological Study of Narrow-mouthed Toad (Kaloula borealis) Population at Myeongji District in Busan Metropolitan City (부산시 명지지구에 서식하는 맹꽁이 개체군 생태연구)

  • Hong, Sung-Gu;An, Chi-Kyung;Kim, Hyun-jung;Oh, Ki Cheol;Park, Sun Young;Na, Sumi;Yi, Hoonbok
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.172-179
    • /
    • 2017
  • The purpose of this study is to analyze the current original habitat and to conserve the narrow-mouthed toad populations. For this study, we used 240 pitfall traps (30 cm height ${\times}$ 20 cm width) to catch the narrow-mouthed toads that inhabit in Myeongji-dong, Gangseo-gu, in Busan metropolitan city from August 2, 2013 to November 7, 2013. We measured the environmental characteristics (soil composition factors, soil moisture, Humidity, soil temperature) for the seven habitat patterns of narrow-mouthed toads based on vegetation types. Main habitats of narrow mouthed toads were flat grassland where grass and false acacia grew and there was wetland all over the place. When analyzing habitats that main habitats of narrow-mouthed toads prefer after selecting representative seven vegetation, it was found that the most narrow-mouthed toads were caught in amur silver grass colony while the least narrow-mouthed toads were caught in bare land. Totally, we caught 846 narrow-mouthed toads over 68 times, and released them into the newly constructed habitat after injection VIE-tag. It seems that the reason for which the least narrow mouthed toads were caught in bare land is that bare land is not suitable for narrow mouthed toads to protect themselves from strong sunlight and to hide themselves from natural enemy. We found that temperature had the greatest influence on activities of narrow mouthed toads and at temperature of less than $15.6^{\circ}C$. We also found that the activities of narrow mouthed toads were remarkably low and then temperature was below $15.6^{\circ}C$. It meant that narrow mouthed toads seemed to go into hibernation. From this research, we could find the prefer habitat after analyzing habitats for the narrow-mouthed toads and could suggest for construction for the better habitat of narrow-mouthed toads.

Quantitative Rainfall Estimation for S-band Dual Polarization Radar using Distributed Specific Differential Phase (분포형 비차등위상차를 이용한 S-밴드 이중편파레이더의 정량적 강우 추정)

  • Lee, Keon-Haeng;Lim, Sanghun;Jang, Bong-Joo;Lee, Dong-Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.1
    • /
    • pp.57-67
    • /
    • 2015
  • One of main benefits of a dual polarization radar is improvement of quantitative rainfall estimation. In this paper, performance of two representative rainfall estimation methods for a dual polarization radar, JPOLE and CSU algorithms, have been compared by using data from a MOLIT S-band dual polarization radar. In addition, this paper presents evaluation of specific differential phase ($K_{dp}$) retrieval algorithm proposed by Lim et al. (2013). Current $K_{dp}$ retrieval methods are based on range filtering technique or regression analysis. However, these methods can result in underestimating peak $K_{dp}$ or negative values in convective regions, and fluctuated $K_{dp}$ in low rain rate regions. To resolve these problems, this study applied the $K_{dp}$ distribution method suggested by Lim et al. (2013) and evaluated by adopting new $K_{dp}$ to JPOLE and CSU algorithms. Data were obtained from the Mt. Biseul radar of MOLIT for two rainfall events in 2012. Results of evaluation showed improvement of the peak $K_{dp}$ and did not show fluctuation and negative $K_{dp}$ values. Also, in heavy rain (daily rainfall > 80 mm), accumulated daily rainfall using new $K_{dp}$ was closer to AWS observation data than that using legacy $K_{dp}$, but in light rain(daily rainfall < 80mm), improvement was insignificant, because $K_{dp}$ is used mostly in case of heavy rain rate of quantitative rainfall estimation algorithm.