Development of 20 kA standard current transformer with an accuracy of 0.005 % and its application (0.005 %의 초정밀 20 kA 표준용 전류변성기의 개발 및 활용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Lee, Sung-Ha;Song, Yang-Sup;Kim, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.953-954
    • /
    • 2007
  • High accurate 20 kA, 6 kA and 2 kA standard current transformers(CTs) with a ratio error within 0.005 % at full rated current have been developed. The CTs are useful as the reference CT of the CT comparator system in the current range of 20 kA to 10 A CT.

  • PDF

Early CT Findings of Coronavirus Disease 2019 (COVID-19) in Asymptomatic Children: A Single-Center Experience

  • Lan Lan;Dan Xu;Chen Xia;Shaokang Wang;Minhua Yu;Haibo Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.919-924
    • /
    • 2020
  • Objective: The current study reported a case series to illustrate the early computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in pediatric patients. Materials and Methods: All pediatric patients who were diagnosed with COVID-19 and who underwent CT scan in Zhongnan Hospital of Wuhan University from January 20, 2020 to February 28, 2020 were included in the current study. Data on clinical and CT features were collected and analyzed. Results: Four children were included in the current study. All of them were asymptomatic throughout the disease course (ranging from 7 days to 15 days), and none of them showed abnormalities in blood cell counts. Familial cluster was the main transmission pattern. Thin-section CT revealed abnormalities in three patients, and one patient did not present with any abnormal CT findings. Unilateral lung involvement was observed in two patients, and one patient showed bilateral lung involvement. In total, five small lesions were identified, including ground-glass opacity (n = 4) and consolidation (n = 1). All lesions had ill-defined margins with peripheral distribution and predilection of lower lobe. Conclusion: Small patches of ground-glass opacity with subpleural distribution and unilateral lung involvement were common findings on CT scans of pediatric patients in the early stage of the disease.

Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers (전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$ (철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.

Development of the iron-cored electronic current transformer (철심 코어형 전자식 변류기 개발)

  • Kang, Yong-Cheol;Kim, Yeon-Hee;Jang, Sung-Il;Park, Jong-Min;Choi, Jung-Hwan;Kim, Yong-Kyun;Lee, Byung-Sung;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.136-137
    • /
    • 2008
  • A current transformer(CT) should provide the faithful reproduction of the primary current to the measurement or the protection equipments. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. A compensating algorithm for the secondary current of the current transformer that removes the effects of the hysteresis characteristics of the iron-core has proposed. The core flux linkage is calculated by integrating the measured secondary current, and then inserted into the flux-magnetizing current curve to obtain the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and added to the measured current to obtain the correct current. This paper describes the innovative new product of the iron-cored electronic current transformer. This product composes an iron-cored CT and an intelligent electronic device(IED) ported the compensating algorithm. The test results of the iron-cored electronic current transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

A Compensated Current Acqaisition Device for CT Saturation (왜곡 전류 보상형 전류 취득 장치)

  • Ryu, Ki-Chan;Gang, Soo-Young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • In this paper, an algorithm to compensate the distorted signals due to Current Transformer(CT) saturation is suggested, First, DWT which can be easily realized by filter banks in real-time applications is used to detect a start point and an end point of the saturation. Secondly, For enough Datas those need to use the least-square curve fitting method, the distorted current signal is compensated by the AR(autoregressive) model using the data during the previous healthy section until pick point of Saturation. Thirdly, the least-square curve fitting method is used to restore the distorted section of the secondary current. Finaly, this algorithm had a Hadware test using DSP board(TMS320C32) with Doble test device. DWT has superior detection accuracy and the proposed compensation algorithm which shows very stable features under various levels of remanent flux in the CT core is also satisfactory. And this algorithm is more correct than a previous algorithm which is only using the LSQ fitting method. Also it can be used as a MU involving the compensation function that acquires the second data from CT and PT.

  • PDF

Performance Analysis of a Lowpass Filter on a CT Saturation Detection Algorithm (변류기 포화 판단 알고리즘의 저역통과 필터에 대한 성능 분석)

  • Gang, Yong-Cheol;Ok, Seung-Hwan;Yun, Jae-Seong;Gang, Sang-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.495-501
    • /
    • 2002
  • A difference based current transformer (CT) saturation detection algorithm uses the third difference of a secondary current to detect the instants of the beginning/end of saturation. The third difference of a secondary current contains high frequency components when a CT is saturated. Thus, an effect of an anti-aliasing lowpass filter implemented in digital protection relays on the detection algorithm should be studied. This paper describes performance analysis of a lowpass filter on the CT saturation detection algorithm. The cutoff frequency of the lowpass filter is normally set to be half of a sampling frequency. In this Paper, two sampling frequencies of 3,840 (Hz) corresponding to 64 sample/cycle (s/c) and 1,920 (Hz) corresponding to 32 (s/c) are studied; the cutoff frequencies of the lowpass filters are set to be 1,920 (Hz), 960 (Hz) and 960(Hz), 480(Hz), respectively. And the proposed algorithm is verified by experiment. A 2nd order Butterworth filter is designed as a lowpass filter. The test results and experiment results clearly indicate that the saturation detection algorithm successfully detects the instants of the beginning/end of saturation even though a secondary current is filtered by the designed lowpass filters.

Performance Analysis on a Low Pass Filter of a CT Saturation Detecting Algorithm Using Difference of the Secondary Current (차분을 이용한 변류기 포화 검출 알고리즘의 저역통과 필터의 영향 분석)

  • Kang, Young-Cheol;Ok, Seung-Hun;Yun, Jae-Sung;Kim, Dae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.249-251
    • /
    • 2001
  • This paper presents performance analysis on a low pass filter of a CT saturation detecting algorithm using difference. At the instants of beginning/end of saturation, the shapes of the secondary current are changed significantly though secondary currents are continuous. At the instants, the second-order or third-order difference of the secondary current has big values because of discontinuity of the first order difference. Thus, the third difference of the current is used to detect the beginning/end of CT saturation. An antialiasing low pass filter removes high frequency components and causes phase lag. A CT saturation detecting algorithm using difference of CT secondary currents is affected by the low pass filter. The algorithm is tested with cutoff frequencies of the filter for the two sampling rates of 64[S/C] and 32 [S/C]. The results of various test cases indicate satisfactory performance of the algorithm.

  • PDF

Development of Electric Instrument of Current and Leakage Current based on NI-9223 and Current Prove (NI-9223과 전류프로브를 이용한 전류 및 누설전류 측정장치 개발)

  • Kim, Sung-Chul;Kim, Un-Sul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.48-53
    • /
    • 2012
  • This paper is purposed to develop portable electric instrument to select NI-9223(National instrument comp.) and clamp meter(HIOKI comp.), which can be used in developing electric instrument, to detect leakage current(ZCT) and current(CT) signals. In this paper, The electric instrument that can interface with current and leakage current instrument(HIOKI 9283), is developed by NI-9223 of NI comp.. HIOKI clamp meter can measure current signals certainly by high-sensitivity of 10 ${\mu}A$ resolution(leakage current : at 10 mA range) and current 1~200A range. The NI-9223 use four 16-bit analog-to-digital converters(ADCs) for true simultaneous sampling at up to 1 MS/s per channel. NI-9223 can synchronize all analog input modules installed in the same chassis to share the same start clock and/or sample clocks. The monitoring program is developed by SignalExpress of LabVIEW. The monitoring program are developed to analyze at simultaneous sampling on electrical signals such as leakage current(ZCT) and current(CT). The developed system verification tests were conducted, and portable electric instrument can be used in place which requires analysis of the actual electrical signal.

Evaluation technique for phase displacement of current transformer comparator (전류변성기 비교기의 위상오차 평가 기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2032-2033
    • /
    • 2008
  • We have developed an evaluation technique for phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured phase displacement in the CT comparator. Thus we can evaluate phase displacement of CT comparator by comparing the calculated and measured phase displacement. The method was applied to CT comparator under test with the phase displacement ranges of $0{\sim}{\pm}7.5$ crad. Finally we have compared the phase displacement of the CT comparator under test theoretically obtained in this method with the specification.

  • PDF