• Title/Summary/Keyword: current(CT)

Search Result 470, Processing Time 0.027 seconds

Fiber-Optic Current Sensor Using a Faraday Rotator Glass Fiber Sensor Coil (Faraday Rotator Glass 광섬유 전류센서)

  • 김기혁;송민호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.28-33
    • /
    • 2004
  • We developed a fiber-optic CT for large current monitoring in power systems. We used a FRG fiber sensor coil to suppress CT output degradation caused by linear birefringence, and different optical sources were used to compare their noise characteristics. From the experiments, we obtained output variation less than $\pm$0.4(%) when the sensor coil suffered mechanical perturbations, and the ASE source showed -23(㏈) less noise in the output than singlemode laser diode.

The Output Property of Optical CT for the 170 kV GIS Owing to the Compensation of Linear Birefringence at Optical Fibers (광섬유의 선형복굴절 보상에 따른 170 kV GIS용 전류 센서의 출력 특성)

  • Jeong Jae-Yong;Kim Byung-Tai
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.55-62
    • /
    • 2005
  • The optical CT was developed to use twisted fibers for 170 kV GIS. The fiber sensor optimized on the optical CT was wound 3 turns and twisted 4 times per a turn at the pipe with a diameter of 130 mm. The measurement error for the linearity which was satisfied the criterion of 'IEC Class-1.0' was less than ± 0.44 % at the transmission type and ± 0.82 % at the reflection type to 2,000 A. At a low current to 200 A, the measurement error was ± 0.69% at the transmission type and ± 1.38 % at the reflection type.

Development of Optical CT and PT using BSO Single Crystal (BSO를 이용한 광CT, PT 개발)

  • Shin, K.H.;Lee, B.K.;Cho, H.K.;Kim, Y.H.;Kim, Y.S.;Park, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.491-494
    • /
    • 1992
  • This paper described the development example of optical CT(Current Transformer) and optical PT (Potential Transformer) which is measurement system of current and voltage of electric power line using Electro-Optic effect and Magneto-Optic effect. We designed the optical CT of 22KV class and 154KV class and an optical PT of 22KV class. And now the filed testing is in progress in a KEPCO's substation.

  • PDF

The Analysis for the characteristics about the Digital Control CT & PT (디지털 제어형 CT 및 PT에 관한 특성 분석)

  • Shin, Jung-Eun;Kim, Jae-Chul;Song, Seung-Youp;Kwon, Young-Mok;Kim, On-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.456-459
    • /
    • 2004
  • Generally, instrument transformer of the core type have been used for measuring current. Because instrument transformer has defects, electronic instrument was appeared. Electronic instrument has many merit-linearity, small size, low cost, etc. Rogowski coil is typical electronic CT and R-divider is typical electronic VT. This paper is introduced a basic concept and theory of electronic current transformer, electronic voltage transformer.

  • PDF

Developing Lessons and Rubrics to Promote Computational Thinking (Computational Thinking역량 계발을 위한 수업 설계 및 평가 루브릭 개발)

  • Choi, Hyungshin
    • Journal of The Korean Association of Information Education
    • /
    • v.18 no.1
    • /
    • pp.57-64
    • /
    • 2014
  • This study aims to suggest lesson plans and evaluation methods for primary pre-service teachers by reviewing the concept of computational thinking(CT) skills and its sub components. To pursue this goal, a literature review has been conducted in regards to CT and the effectiveness of programming courses. In addition, the Scratch educational programming functions were analyzed yielding six CT elements(data representation, problem decomposition, abstraction, algorithm & procedures, parallelization, simulation). With these six elements, one semester lesson plans for 15 weeks that represent the connections with six CT elements were designed. Based on the PECT(Progression of Early Computational Thinking) model and the CT framework a rubric to evaluate learners' proficiency levels(basic, developing, proficient) revealed in their final projects was developed as well. Upon a follow-up empirical study, the lesson plans and the rubric suggested in the current study are expected to be utilized in teachers' colleges.

A Current Differential Relaying Algorithm for Transmission Lines Using an Advanced Compensation Algorithm of CTs (보상알고리즘을 적용한 송전선 보호용 전류차동 알고리즘)

  • Kang, Y.C.;Lim, U.J.;Choi, J.W.;Jin, S.Y.;Cho, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.323-325
    • /
    • 2003
  • A current differential relay may maloperate for external faults with CT saturation and requires an additional method to cope with the problem. This paper proposes a current differential relaying algorithm for transmission line protection using an advanced compensation algorithm of the secondary current of CTs. The compensation algorithm is unaffected by a remanent flux. The proposed algorithm does not need an additional method for CT saturation and thus can achieve high stability for an external fault.

  • PDF

Current Status and Improvements of Transfered PET/CT Data from Other Hospitals (외부 반출 PET/CT 영상 현황 및 개선점)

  • Kim, Gye-Hwan;Choi, Hyeon-Joon;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.38-40
    • /
    • 2010
  • Purpose: This study was performed to find the current problems of PET/CT data from other hospitals. Materials and Methods: The subjects were acquired from 64 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data were reviewed and the phone questionnaire survey about these were performed. Results: PET/CT data from 39 of 64 hospitals (61%) included all transaxial CT and PET images with DICOM (Digital Imaging Communications in Medicine) standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. Conclusion: The majority of hospitals provided limited PET/CT data which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data to transfer including all transaxial CT and PET images with DICOM standard format.

  • PDF

Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer (병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점)

  • Hyun, Seung-Hyup;Choi, Joon-Young;Lee, Su-Jin;Cho, Young-Seok;Lee, Ji-Young;Cheon, Mi-Ju;Cho, Suk-Kyong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: This study was performed to find the current problems of positron emission tomography/computed tomography(PET/CT) data on CD for inter-hospital transfer. Materials and Methods: The subjects were 746 consecutive $^{18}F$-fluorodeoxyglucose PET/CT data CDs from 56 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data CDs were reviewed and the email questionnaire survey about this was performed. Results: PET/CT data CDs from 21 of 56 hospitals(37.5%) included all transaxial CT and PET images with DICOM standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. According to this survey, the main reason of limited PET/CT data on CD for inter-hospital transfer was that the data volume of PET/CT was too large to upload to the Picture Archiving and Communication System. Conclusion: The majority of hospitals provided limited PET/CT data on CD for inter-hospital transfer, which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data on CD for inter-hospital transfer including all transaxial CT and PET images with DICOM standard format.

Operation characteristics of SFCLs combined with a transformer in three-phase power system

  • Jung, B.I.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.30-33
    • /
    • 2013
  • The studies of superconducting fault current limiter (SFCL) for reduction of the fault current are actively underway in the worldwide. In this paper, we analyzed the characteristics of a new type SFCL using the conventional transformer and superconducting elements combined mutually. The secondary and third windings of this SFCL were connected the load and the superconducting element, respectively. The electric power was provided to load connected to secondary windings of the transformer in normal state of power system. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the ripple phenomenon of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the CT(current transformer) and then turn-on and turn-off switching behavior of the SFCL was performed by the SCR(silicon-controlled rectifier). As a result, the proposed SFCL limited the fault current within a half-cycle efficiently. We confirmed that the fault current limitation rate was changed according to the winding ratio of a transformer.

New horizon of earth reinforcement technique - current and future -

  • Otani, Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.514-527
    • /
    • 2007
  • Earth reinforcement techniques are used worldwide and offer proven solutions to a wide range of geotechnical engineering problems. Here in this paper, recent developments of three major reinforced soil retaining wall methods in Japan were introduced in order to show how the current situation of this technique in Japan is. And the statistical data for the volume of the use was also shown, such as the total volume of the use, the scales of the structures, layout of the earth reinforcement, fill materials, and foundation conditions. Some of the case histories were also introduced with photographs and figures. And then, as one of recent research activity by the author, the study on the application of X-ray CT for the problem of earth reinforcement method combined with other method such as piling and soil improvement was introduced. In this study, a series of model test for several reinforced ground with geogrids was conducted using a newly developed test apparatus. Then, the behavior in the soil box was scanned after settlement using X-ray CT scanner. Based on these test results, the reinforcing effect by the geogrids and the soil arching effect over the pile heads was discussed precisely and those are done in 3-D with nondestructive condition. Finally, the effectiveness of the use of X-ray CT scanner in geotechnical engineering was promised.

  • PDF