• Title/Summary/Keyword: cure time

Search Result 482, Processing Time 0.03 seconds

Influence of Mastication en Properties of Carbon Black-Filled NR Compounds

  • Park, Sung-Seen
    • Macromolecular Research
    • /
    • v.8 no.2
    • /
    • pp.73-79
    • /
    • 2000
  • The influence of mastication of natural rubber (NR) on properties of carbon black-filled NR compounds was studied. Variations of viscosities of the masticated NR and the carbon black-filled NR compound by heating were also investigated. The viscosities of the compounds decreased by increasing the mastication time of the raw rubber. The viscosities of the masticated NR and the compounds increased by increasing the heating time. This was explained by the combination reaction between functional groups in the rubber. The viscosity increment of the masticated rubber and the compounds by heating became larger with increased mastication time. Cure rate of the compound became faster by increasing the mastication time. Modulus of the vulcanizate made of the rubber masticated for a long time was higher than that of the vulcanizate made of the rubber masticated for a short time while elongation at break of the former was shorter than that of the latter. This was explained by the content of bound rubber and chain length of the rubber molecules.

  • PDF

Adhesion Properties of Rubber Composite with Direct Blending Technique and Adhesive Composition (직접블렌딩 기술과 접착제 조성이 고무복합체 물성에 미치는 영향)

  • Lee, Seong-Jae;Chang, Young-Wook;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.34 no.3
    • /
    • pp.253-261
    • /
    • 1999
  • The cure properties of rubber compounds containing different adhesive compositions were examined. As the amounts of tannin were increased in the adhesive composition, the scorch time was increased and cure rate was decreased due to the size and shape of tannin molecules. Also, the effect of adhesive composition on the adhesion between rubber and fiber was examined by TCAT(Tire Cord Adhesion Test), The reinforcing cords used in this study were mon ofilaments of nylon 610 and nylon 66. According to the results, the optimum adhesion strength between rubber and fiber could be obtained with adhesives whose molar ratios of formaldehyde/resorcinol were above 5/1 in the recipes. Although the level of dip pick-up(DPU) on the reinforcing cord affects the adhesion strength, the DPU of nylon 610 monofilament did not affect the adhesion strength because the level of DPU was constant regardless of the adhesive compositions. In this case, the adhesion strength with the adhesive composition could be explained with the behavior of tannin in the adhesive.

  • PDF

Studies on Rheological Properties and Cure Behaviors of Difunctional Epoxy/Biodegradable Poly(butylene succinate) Blends (2관능성 에폭시/생분해성 폴리부틸렌 숙시네이트 블렌드의 유변학적 특성 및 경화거동에 관한 연구)

  • 박수진;김승학;이재락;민병각
    • Composites Research
    • /
    • v.15 no.6
    • /
    • pp.8-15
    • /
    • 2002
  • In this work, the effect of biodegradable poly(butylene succinate)(PBS) in difunctional epoxy(21:P) resin was investigated in terms of rheological properties, cure kinetics, thermal stabilities, and mechanical interfacial properties. Rheological properties of the blend system were measured under isothermal condition using a rheometer. Cross-linking activation energies($\textrm{E}_c$) were determined from the Arrhenius equation based on gel time and curing temperature. The $\textrm{E}_c$ was increased in the presence of 10 wt% PBS as compared with neat 2EP. From the DSC results of the blends, the cure activation energies($\textrm{E}_a$) showed a similar behavior with $\textrm{E}_c$ due to the increased intermolecular interaction between 2EP and PBS. The decomposed activation energies($\textrm{E}_t$) for the thermal stability derived from the integral method of Horowitz-Metzger equation, were also increased in 10 wt% PBS. In addition, 20 wt% PBS showed the highest critical stress intensity factor($\textrm{E}_{IC}$). which was explained by increasing the fracture toughness of the 2EP/PBS blend systems.

Trenchless Repairing-Reinforcing Process of Underground Pipes with Advanced Composite Materials (신소재 복합재료를 이용한 비굴착 지하매설관 보수-보강공법)

  • 진우석;권재욱;이대길;유애권
    • Composites Research
    • /
    • v.15 no.1
    • /
    • pp.21-31
    • /
    • 2002
  • To overcome the disadvantages of conventional excavation technology various trenchless (or excavation free, or no-dig) repair-reinforcement technologies have been developed and tried. But trenchless technologies so far developed have some drawbacks such as high cost and inconvenience of operation. In this study, a repairing-reinforcing process for underground pipes with glass fiber fabric polymer composites using VARTM (Vacuum Assisted Resin Transfer Molding) has been developed. The developed process requires shorter operation time and lower cost with smaller and simpler operating equipments than those of the conventional trenchless technologies. For the reliable operation of the developed method, a simple method to apply pressure and vacuum to the reinforcement was devised and flexible mold technology was tried. Also, resin filling and cure status during RTM process were monitored with a commercial dielectrometry cure monitoring system, LACOMCURE. From the investigation, it has been found that the developed repairing-reinforcing technology with appropriate process variables and on-line cure monitoring has many advantages over conventional methods.

Papers : Simultaneous Monitoring of Strain and Temperature During and After Cure of Unsymmetric Cross - ply Composite Laminate Using Fiber Optic Sensors (논문 : 비대칭 직교적층 복합재료 적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 모니터링)

  • Gang,Hyeon-Gyu;Gang,Dong-Hun;Hong,Chang-Seon;Kim,Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • In this paper, we present the simulation monitoring of strain and temperature during and after the cure of unsymmetric composite laminate using fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPI) hybrid sensors are used to measure those measurands. The characteristic matrix of the sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilised as a lighr source. Two FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate in different directions and different locations. We perform a real time monitoring of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in a thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

A Historical Consideration on the External Treatment theories and diseases for which medicine is efficacious (외치료법(外治療法)의 이론(理論)과 적응증(適應症)에 대한 사적(史的) 고찰(考察))

  • Moon, Woo-Sang;Lee, Byung-Wook;Ahn, Sang-Woo;Kim, Eun-Ha
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.2
    • /
    • pp.1-21
    • /
    • 2004
  • 1) Objective External treatments have various curative effects. So it had been used to cure various patients. But, it has a limited sphere of application in the present South Korea. Therefore we would like to bring out its sphere of application and detailed method in the oriental medicine classics. 2) Methodologies We have researched external treatment history according to below the procedure. (1) Making a related words list: We have used existing external treatments technical books to make a list. It has been connected with external treatments. It includes not only technical terms, but also general terms. (2) Searching sentence: We have searched sentence that contain terms that related with external treatments. (3) Analysis of related sentence: We have searched and classified sentence by disease. (4) Analysis of external treatment methods. 3) Conclusions From long time ago people have used external treatment to cure various disease. According to the ${\ulcorner}Nei-Jing{\lrcorner}$, hot compress therapy, fumigation therapy and bathing therapy had been used to cure blockage syndrome, muscle disease, carbuncle and cellulitis. Thereafter, a sphere of external treatment had gradually enlarged. (1) After all its sphere had included dermatologic, psychologic, internal, ophthalmic, otolaryngologic, obstetrics, gynecologic, pediatric and surgical diseases. (2) External treatment methods have contained hot compress therapy, fumigation therapy, bathing therapy, application therapy, medication bag therapy, medication plug therapy, medication massotherapy, aroma therapy and so on. (3) Medication types of external treatment have contained ointment, juice, infusion, powder, suppository and so on.

  • PDF

Fracture Toughness Measurement of the Semiconductor Encapsulant EMC and It's Application to Package (반도체 봉지수지의 파괴 인성치 측정 및 패키지 적용)

  • 김경섭;신영의;장의구
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.519-527
    • /
    • 1997
  • The micro crack was occurred where the stress concentrated by the thermal stress which was induced during the cooling period after molding process or by the various reliability tests. In order to estimate the possibility of development from inside micro crack to outside fracture, the fracture toughness of EMC should be measured under the various applicable condition. But study was conducted very rarely for the above area. In order to provide a was to decide the fracture resistance of EMC (Epoxy Molding Compound) of plastic package which is produced by using transfer molding method, measuring fracture is studied. The specimens were made with various EMC material. The diverse combination of test conditions, such as different temperature, temperature /humidity conditions, different filler shapes, and post cure treatment, were tried to examine the effects of environmental condition on the fracture toughness. This study proposed a way which could improve the reliability of LOC(Lead On Chip) type package by comparing the measured $J_{IC}$ of EMC and the calculated J-integral value from FEM(Finite Element Method). The measured $K_{IC}$ value of EMC above glass transition temperature dropped sharply as the temperature increased. The $K_{IC}$ was observed to be higher before the post cure treatment than after the post cure treatment. The change of $J_{IC}$ was significant by time change. J-integral was calculated to have maximum value the angle of the direction of fracture at the lead tip was 0 degree in SOJ package and -30 degree in TSOP package. The results FEM simulation were well agreed with the results of measurement within 5% tolerance. The package crack was proved to be affected more by the structure than by the composing material of package. The structure and the composing material are the variables to reduce the package crack.ack.

  • PDF

Thermal Stability of Glass Powder and Rubber-Filled Phenolic Resins and Dynamic Mechanical Properties of Glass Braid/Phenolic Composites (유리분말 및 고무 충진 페놀수지의 열안정성 및 Glass Braid/페놀수지 복합재료의 동역학적 열특성)

  • Yoon, Sung Bong;Cho, Donghwan;Lee, Geon-Woong
    • Journal of Adhesion and Interface
    • /
    • v.8 no.4
    • /
    • pp.14-22
    • /
    • 2007
  • In the present study, the effect of milled glass powder and liquid-type nitrile rubber (NBR) on the thermal stability of phenolic resin and the dynamic mechanical properties of glass braid/phenolic composites has been investigated by means of thermogravimetric analysis and dynamical mechanical analysis. It was found that both milled glass power and NBR filled in the waterborne phenolic resin significantly influenced the thermal stability of phenolic resins and the storage modulus and tan delta of the composites. The presence of glass powder increased the thermal stability of the phenolic resin, whereas the presence of NBR resulted in the weight loss in the specific temperature range. The thermal stability of the phenolic resins without and with the fillers was dependent not only on the cure temperature but also on the cure time. The variation of the storage modulus and tan ${\delta}$ of strip-type glass braid/phenolic composites was also influenced with the introduction of glass powder and NBR to the phenolic matrix as well as by the cure conditions given.

  • PDF

A New Bot Disinfection Method Based on DNS Sinkhole (DNS 싱크홀에 기반한 새로운 악성봇 치료 기법)

  • Kim, Young-Baek;Youm, Heung-Youl
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.6A
    • /
    • pp.107-114
    • /
    • 2008
  • The Bot is a kind of worm/virus that can be used to launch the distributed denial-of-service(DDoS) attacks or send massive amount of spam e-mails, etc. A lot of organizations make an effort to counter the Botnet's attacks. In Korea, we use DNS sinkhole system to protect from the Botnet's attack, while in Japan "so called" CCC(Cyber Clean Center) has been developed to protect from the Botnet's attacks. But in case of DNS sinkhole system, there is a problem since it cannot cure the Bot infected PCs themselves and in case of CCC there is a problem since only 30% of users with the Botnet-infected PCs can cooperate to cure themself. In this paper we propose a new method that prevent the Botnet's attacks and cure the Bot-infected PCs at the same time.

In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements (치과용 레진 시멘트의 중합 수축률 특성에 관한 연구)

  • Kim, Tae-Hoon;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: The shrinkage of dental resin cement may cause several clinical problems such as distortion that may jeopardize the accurate fit to the prepared tooth and internal stress within the restorations. It is important to know the polymerization shrinkage-strain of dental resin cement to reduce clinical complications. The purpose of this study was to investigate the polymerization shrinkage-strain kinetics of six commercially available dental resin cements. Material and methods: Three self-cure resin cements (Fujicem, Superbond, M-bond) and three dual-cure resin cements (Maxcem, Panavia-F, Variolink II) were investigated. Time dependent polymerization shrinkage-strain kinetics of the materials were measured by the Bonded-disk method as a function of time at $23^{\circ}C$, with values particularly noted at 1, 5, 10, 30, 60, 120 min after mixing. Five recordings were taken for each materials. The data were analyzed with one-way ANOVA and Scheffe post hoc test at the significance level of 0.05. Results: Polymerization shrinkage-strain values were 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90% for Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II, respectively at 120 minutes after the start of mixing. Panavia F exhibited maximum polymerization shrinkage-strain values, but Superbond showed minimum polymerization shrinkage-strain values among the investigated materials (P < .05). There was no significant differences of shrinkage-strain value between Maxcem and M bond at 120 minutes after the start of mixing (P > .05). Most shrinkage of the resin cement materials investigated occurred in the first 30 minutes after the start of mixing. Conclusion: The onset of polymerization shrinkage of self-cure resin cements was slower than that of dual-cure resin cements after mixing, but the net shrinkage strain values of self-cure resin cements was higher than that of dual-cure resin cements at 120 minutes after mixing. Most shrinkage of the dental resin cements occurred in the first 30 minutes after mixing.