• Title/Summary/Keyword: crown to implant ratio

Search Result 38, Processing Time 0.031 seconds

SINUS GRAFT AND VERTICAL AUGMENTATION OF MAXILLARY POSTERIOR ALVEOLAR RIDGE USING MANDIBULAR RAMAL BLOCK BONE GRAFT (상악동 골이식술과 하악지 자가골 블록을 이용한 상악 구치부 치조제 수직증강술)

  • Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.276-281
    • /
    • 2010
  • The maxillary posterior area is the most challenging site for the dental implant. After missing of teeth on maxillary posterior area due to periodontal problems, the remaining alveolar ridge is usually very thin because of not only pneumatization of maxillary sinus but also destruction of alveolar bone. The maxillary sinus bone graft procedure is one of the most predictable and successful treatments for the rehabilitation of atrophic and pneumatized endentulous posterior maxilla. But, in case of severe destruction of alveolar bone due to periodontal problems, very long crown length is still remaining problem after successful sinus graft procedures. We performed vertical augmentation of maxillary posterior alveolar ridge using mandibular ramal block bone graft with simultaneous sinus graft. After this procedures, we could get more favorable crown-implant ratio of final prosthodontic appliance and more satisfactory results on biomechanics. This is a preliminary report of the vertical augmentation of maxillary posterior alveolar ridge using mandibular ramal block bone graft with simultaneous sinus graft, so requires more long-term follow up and further studies.

Do Certain Conditions Favor the Use of Autogenous Bone Graft Over Bone Substitutes for Maxillary Sinus Augmentation?

  • Lee, Ji-Hyun;Cho, Yeong-Cheol;Sung, Iel-Yong;Choi, Jong-Ho;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • v.12 no.2
    • /
    • pp.48-57
    • /
    • 2019
  • Purpose: To investigate whether there are specific surgical or clinical conditions where the use of autogenous bone (AB) is superior to the use of bone substitutes (BSs) for maxillary sinus floor augmentation (MSFA). Materials and Methods: We retrospectively analyzed 386 implants after MSFA in 178 patients. The implants were divided into five groups according to the sinus graft material used. Risk factors for implant failure in MSFA, and correlation between residual bone height (RBH) and graft materials in terms of implant survival were investigated. To investigate risk factors for implant failure in MSFA, implant survival according to graft materials, patients' sex/age, surgical site, RBH, healing period prior to prosthetic loading, staged- or simultaneous implantation with MSFA, the crown-to-implant ratio, prosthetic type, implant diameter, and opposite dentition were evaluated. Result: The cumulative 2- and 5-year survival rates of implants placed in the grafted sinus (independent of the graft material used) were 98.7% and 97.3%, respectively. None of the investigated variables were identified as significant risk factors for implant failure. There was also no statistical significance in implant survival between graft materials. Conclusion: There were no specific surgical conditions in which AB was superior to BSs in terms of implant survival after MSFA.

VERTICAL ALVEOLAR BONE AUGMENTATION USING THIN BLOCK AND CHIP BONE GRAFT TECHNIQUE : CASE REPORT (Thin Block and Chip Bone Graft Technique을 이용한 치조골 수직 증강술 : 증례보고)

  • Oh, Sung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.108-113
    • /
    • 2008
  • It would be desirable to regenerate bone vertically in a predictable way; such a technique would allow for more favorable implant - crown ratio and better esthetics for implant placement. Traditionally, several techniques has been proposed for this purpose including GBR with particulated bone and block bone graft using mandible or illium however, the efficacy of these techniques has not been firmly established because they have some week points or complications each other that it is difficult to draw firm conclusion for superiority. In recent years, We have treated 11-cases of vertical deficiency of alveolar bone using thin block and chip bone graft technique and the postoperative results showed good prognosis with few complications. So we report the results of its treatment and cases with review of literature.

Accuracy of periodontal probe visibility in the assessment of gingival thickness

  • Kim, Young-Sung;Park, Ji-Sun;Jang, Young-Hun;Son, Jung-Hun;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.1
    • /
    • pp.30-39
    • /
    • 2021
  • Purpose: The present study was undertaken to examine whether periodontal probe visibility (PV) accurately reflects gingival thickness (GT) and to identify factors affecting PV using cluster and multivariate analyses. Methods: The clinical characteristics of the maxillary central incisors (n=90 subjects) were examined. Clinical photographs, sex, PV, probing depth, gingival width, papilla height, GT as measured with an ultrasonic device, and the ratio of crown width to crown length were recorded. Multivariate analysis, using multinomial baseline-category logistic regression, was used to identify factors predictive of PV. Cluster analysis was used to identify gingival biotypes. Results: In the multivariate analysis, sex was the only significant predictor of PV (odds ratio, 6.48). Two clusters of subjects were created based on morphometric parameters. The mean GT among cluster A subjects was significantly lower than that among cluster B subjects (P=0.015). No significant difference was found between cluster A and B subjects in terms of PV score (P=0.583). Conclusions: Periodontal PV was not associated with GT as measured directly using an ultrasonic device. Sex was a highly significant predictor of periodontal PV. GT was found to be correlated with morphological characteristics of the periodontium.

Clinical Outcome of Implants Placed in Grafted Maxillary Sinus Using Recombinant Human Bone Morphogenetic Protein-2: A 5-year Follow-Up Study

  • Yu-Jeong Baek;Jin-Ho Lee;Hyo-Jeong Kim;Bok-Joo Kim;Jang-Ho Son
    • Journal of Korean Dental Science
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • Purpose: To investigate the 5-year outcome of dental implants placed in a grafted maxillary sinus using recombinant human bone morphogenetic protein-2 (rhBMP-2). Materials and Methods: We retrospectively analyzed 27 implants after maxillary sinus floor augmentation (MSFA) using rhBMP-2 in 16 patients between January 2016 and March 2017. The study evaluated two outcome variables: (1) 5-year cumulative survival and success rate of the implant after functional loading and (2) marginal bone loss (MBL) for implant failure. Results: The average residual bone height was 4.78±1.53 mm. The healing period before loading was 8.35±2.34 months. The crown-to-implant ratio was 1.31±0.26. The 5-year cumulative survival and success rate after functional loading were 100% and 96.3%, respectively. The 5-year average MLB was 0.89±0.82 mm. Conclusion: Placing dental implants with MSFA using rhBMP-2 is a reliable procedure with favorable long-term survival and success rates.

RECONSTRUCTION OF SEVERE BUCCO-LINGUAL BONE RESORPTION AREA USING "RIDGE SPLITTING TECHNIQUE" (심한 협-설골 위축에서 치조골 수평 확장술을 이용한 골 재건)

  • Yeo, Duck-Sung;Lim, So-Yeon;Lee, Hyun-Jin;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.590-594
    • /
    • 2006
  • Dental implant has become one of the important option for completely or partially edentulous patients, But it is challenging to reconstruct the severely atrophic ridge. Insufficient bone volume could restrict to place the wide and long implant and because of excessive interocclusal clearance, improper prosthetics could be produced. In this case bone augmentation for implant dentistry is necessary procedure to improve the insufficient bone volume. Therefore, bone augmentation or GBR is the most important procedure for successful implant placement and for ideal crown- root ratio. There are various bone augmentation techniques have been introduced recently; like block bone graft, distraction osteogenesis, inlay graft, onlay graft, etc.... In severe bucco-lingual resorption area, ridge splitting is the first choice of the treatment, because it provides a place for implantation and also has compaction effect. This technique may be indicated for sharp mandible and maxillary ridges in patients whose bone quantity is inadequate for primary stabilization. We report that the clinical experience of bone augmentation using ridge splitting technique in bucco-lingual bone resorption area.

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

The relationship between clinical crown form and gingival feature in upper anterior region (상악 전치부에서 치관 형태에 따른 치은의 특성)

  • Kim, Soo-Hyung;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.761-776
    • /
    • 2005
  • The purpose of the present study was to examine the relationship between the form of the clinical crowns in the maxillary anterior segment and the clinical feature of gingiva such as morphological characteristics and the gingival thickness. Fifty periodontally healthy subjects were clinically examined regarding the probing depth, the thickness of the free gingiva, and the width of the keratinized gingiva. From study models of the maxillary anterior region, the width at cervical third(CW) and the length(CL) of the clinical crown, the papillary height, and the gingival angle of the 6 anterior teeth were measured. Each tooth was classified into 4 groups (longnarrow, NL; narrow, N; wide, W; short-wide, WS) according to CW/CL ratio and all the data were compared between groups NL and WS using independent t-test. Stepwise multiple regression analysis was performed for each tooth region with the gingival thickness at the level of sulcus bottom, the width of keratinized gingiva, and gingival angle as the dependent variables. As the results, the NL group of the upper anterior teeth displayed, higher papilla height, and narrower keratinized gingiva, more acute gingival angle resulting in pronounced "scalloped" contour of the gingival margin, compared to the WS group. There was no significant difference between groups NL and WS with respect to probing depth and the gingival thickness. The regression analyses demonstrated that the gingival thickness in central incisors was significantly associated to the mesio-distal width and bucco-lingual width of the crown, and labial probing depth. The width of keratinized gingiva was significantly associated with labial probing depth in central incisors and with proximal probing depth and gingival angle in lateral incisors, and with labial and proximal probing depth, and gingival angle in canines. The gingival angle was significantly associated with papillary height and CW/CL ratio and additionally with proximal probing depth in central incisors, with the width of keratinized gingiva in lateral incisors, and with labial probing depth and the width of keratinized gingiva in canines. These results indicate that the form of clinical crown in upper anterior region could influence the clinical feature of gingiva and the influencing factors might be different according to the tooth region.

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.