• 제목/요약/키워드: crown material

검색결과 285건 처리시간 0.027초

이민기를 포함하는 비스 또는 트리 크라운에테르의 합성 (V) (Syntheses Bis or Tri Crown Ethers Containing Imine Group(V))

  • 장승현;김정성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2003
  • We report herein synthetic results obtained six new types of bis-benzocrown ethers containing imine group. Bis crown ethers l~3 are aminobenzo-15-crown-5-ether linked with terephthalaldehyde, isophthalaldehyde, phthaldehyde respectively by imine reaction. Bis crown ethers l~3 are different distances in each crown ether rings. Bis crown ether 4 has large cavity in crown ethers. Functionalized crown ether 5 is synthesized amonobenzo-l5-crown-5-ether and terephthaladehyde same ratio at one to one. Bis crown ether 6 has phothosensitive linkage between crown ethers. Bis crown ether 7 is prepared by amonobenzo-l5-crown-5-ether and triethyl ortho formate. 4'-Nitrobenzo-crown ethers and 3',4'-dinitrobenzo-crown ethers were prepared by nitration of benzo crown ethers, obtained from the reaction of catechol and oligoethylene glycol ditosylate. Crown ethers containing aldehyde group were synthesized from the reaction of 3,4-dihydroxybenzaldehyde and corresponding ditosylate respectively. The synthesized crown ethers were characterized respectively by IR, NMR. GC-Mass.

  • PDF

MATRIX에 따른 임시치관의 변연적합도에 관한 연구 (THE MARGINAL ACCURACY OF TEMPORARY CROWN WITH DIFFERENT MATRIX)

  • 주태훈;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.59-66
    • /
    • 1991
  • This study was designed to investigate the marginal accuracy of resin temporary crown with different matrix in indirect technique. Matrices were made from irreversible hydrocolloid impression material, putty type of vinyl polysiloxane silicone rubber and vacuum formed plastic sheet. The marginal discrepancies of the temporary crowns were measured using a measuring microscope. The obtained results were as follows 1. The marginal accuracy temporary crown using vinyl polysiloxane silicone rubber or vacuum formed plastic form was better than that of the temporary crown using irreversible hydrocolloid impression material. 2. The marginal accuracies of the temporary crown using the irreversible hydrocolloid impression material and putty type of the vinyl polysiloxane silicone rubber obtained the best results at the distal measuring point. 3. The vacuum formed plastic form was recorded a more acceptable marginal accuracy at the distal and mesial measuring points.

  • PDF

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • 서상진
    • 대한심미치과학회지
    • /
    • 제26권2호
    • /
    • pp.68-83
    • /
    • 2017
  • 치과용 CAD/CAM이 점차 보급됨에 따라, 사용할 수 있는 material의 종류와 활용할 수 있는 범위도 늘어나고 있다. 치과용 캐드캠의 가장 큰 장점은 한번의 방문으로 최종 보철물을 제작 할 수 있다는 점인데, 지르코니아나 복잡한 심미 보철의 경우 하루만에 제작하기 힘든 경우가 많다. 이러한 경우 임시치관용 PMMA 재료를 사용하여, 환자에게 심미성과 기능성을 가진 임시치관을 제공할 수 있으며 최종보철물에 대한 test crown이나 template등으로 활용할 수 있다. 그리고 원내에서 5축 밀링기로 가공한다면 임시치관을 빠른 시간에 큰 범위까지 정밀하게 제작할 수 있다. 이 글에서는 원내에서 가공하는 PMMA 임시치관의 다양한 활용과 임상증례에 대해 살펴보고자 한다.

Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석 (The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant)

  • 정관호;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

피스톤크라운의 열간단조공정 최적화를 위한 유한요소해석 (FEM Analysis for Optimization of Hot Forging Process of Piston Crown)

  • 민규영;임성주;최호준;최석우;박용복
    • 소성∙가공
    • /
    • 제18권6호
    • /
    • pp.444-447
    • /
    • 2009
  • Piston crown to the hot forge a unified nature of the product has a shape with multi-level step forging process, so if you are not a mechanical professional, this process could lead to a significant loss to the material. Therefore, material technology in minor terms; continue to improve the collection rate that undamaged the product material. The piston crown and the manufacturing products such as marine diesel engines are being forged to reduce costs and to improve mechanical properties. Piston crown molding is a hot forging process that works in large volume forging products. Because of the size of the hard plastic material flow process for improving the design and actual field experience through advanced plastic technology, it is important to interpret the results. Also for many experimental plastic procedures, the accumulation of results is very important.

건강보험 급여화 관련 크라운보철물 제작실태 연구 (A study on the production environment of crown prosthesis for National Health Insurance benefit)

  • 조미향;이희경;남신은
    • 대한치과기공학회지
    • /
    • 제40권2호
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the production environment of crown prosthesis for National Health Insurance(NHI) benefit. Methods: This study carried out self-administered questionnaire survey from September 1, 2016 to October 31 by having research subjects as 261 dental technician. Except 100 copies with incomplete response, 161 copies were used as the materials of final analysis. Results: Unlike gold crowns, the material cost of metal crowns was paid at the dental laboratory(86.3%). Total material consumption for making metal crown was more than gold crown(63.4%), especially for the finishing and polishing processes(78.3%). The subjects responded that a routine dental laboratory fee of crown prosthesis is unreasonable, and it is necessary to adjust and improve it(metal crown 96.2%, gold crown 96.9%). NHI coverage dental prosthesis was not marked on the order form(46.0%), and the dental laboratory fee of that was nor received(64.0%). Conclusion : It is necessary to estimate the NHI cost level of the crown prosthesis by reflecting the production environment and engineering process in dental laboratories. In addition, institutional arrangement should be backed up so that dental laboratories can receive appropriate dental laboratory fee.

Synthesis and fluorescent property investigation of novel fluoroionophores

  • Huang, Zhi Bin;Wang, Zhi Ping;Kang, Tai-Jong;Kwon, Young-Hwan;Kim, Sung-Nam;Chang, Seung-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.428-429
    • /
    • 2005
  • Novel fluoroionophore of dibenzothiazolyl-dibenzo-crown ethers were synthesized from diformal-dibenzo 18-crown-6 (24-crown-8) with 2-aminothiophenol, and they were characterizated by $^1H$-NMR, $^{13}C$-NMR, IR spectrum, Mass spectrum, elemental analyses, respectively. The fluorescent properties of the newly synthesized crown ether were examined with $Li^+$, $Na^+$, $K^+$, $Rb^+$, $Cs^+$, $NH_4^+$ and $CF_3COOH$, respectively. With protonation using $CF_3COOH$, the absorption bands of the new crown ethers are further blue shifted, the maximum emission wavelengths further red shifted.

  • PDF

피스톤크라운의 열간단조공정 최적화를 위한 유한요소해석 (FEM Analysis for Optimization of Hot Forging Process of Piston Crown)

  • 민규영;임성주;최호준;최석우;박용복
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.98-101
    • /
    • 2009
  • Piston crown to the hot forge a unified nature of the product has a shape with multi-level step forging process, so if you are not a mechanical process that can be a significant loss is material. Therefore, minor in terms of material technology; continue to improve the collection rate should be. The Piston crown and the manufacturing of products such as marine diesel engines, reducing costs and to improve mechanical properties of the method are being forged. Piston crown molding hot forging process the large volume forging products handling because of the size of the size of the hard plastic material flow process for improving the design and actual field experience through advanced plastic technology, and it is important to interpret the results and for many experimental plastic The accumulation of results is very important.

  • PDF

Double crown retained RPD의 4년 임상 관찰 (DOUBLE CROWN RETAINED REMOVABLE PARTIAL DENTURE - 4 YEARS IN RETROSPECT)

  • 이석형
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.73-82
    • /
    • 2004
  • Statment of problem : Little in known about the importance of selection of various double crowns as retainer in determining the outcome of treatment with double crown retained removable partial denture. Purpose : To obtain information about the effects and the results of this treatment modality. Material and methods : This study describes 61 double crown retained removable partial dentures worn by 51 patients from Samsung Medical Center, Seoul a time ranging between 6 and 48 months and evaluate occlusal contacts on the denture teeth, denture movement, incidence of denture relining, denture retention, fracture of dentures and abutments, hygiene, residual ridge inflammatory changes, number of lost abutment,. interruption of denture use. Results : One tenth of all the restorations were relined. Restorations in 21 arches fractured repeatedly for various reasons . There was no apparent interrelationship between fractures and the five groups. Conclusion : Good prognoses of removable partial dentures were shown in all groups(Kennedy Classes I, II, III, combination and few remaining abutment).

전부피개관의 물성과 시멘트의 물성이 시멘트 내부의 응력에 미치는 영향 (Characterization of the Stress in the Luting Cement layer Influenced by Material Properties of Full Veneer Crown)

  • 이준영;이규복;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.1-12
    • /
    • 2009
  • 이 논문의 목적은 시멘트 층 내의 응력분포에 대해 금관의 물성과 시멘트의 물성 및 교합력의 방향이 미치는 영향을 이차원 유한요소분석으로 조사하는 것이다. Chamfer 변연을 가지는 23개의 하악 제1대구치 모델을 상정하였다. 금관의 재질은 제 3형 금합금, Ni-Cr 합금, 세라믹, 복합레진 등 4가지이며, 시멘트의 재질은 인산 아연 시멘트와 글라스 아이오노머 시멘트 등 2가지이다. 치축과 평행하게 또는 경사지게 하여 1N 단위로 금관에 하중을 가했다. 시멘트층의 응력은 금관 변연이 다른 곳보다 더 높았다. 치축에 평행한 하중이 치축에 경사진 하중보다 더 높은 응력을 발생시켰다. 경도가 더 큰 금관은 시멘트 층 내에서 더 높은 응력을 나타냈으며, 더 높은 응력은 더 큰 Young's modulus을 나타냈다.