• Title/Summary/Keyword: cross-flow filtration

Search Result 43, Processing Time 0.032 seconds

AEROBIC DEGRADATION OF A NON-IONIC SURFACTANT IN A MEMBRANE BIOREACTOR(MBR)

  • Choi, In-Su;Wiesmann, Udo
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.81-91
    • /
    • 2007
  • A membrane bioreactor (MBR) was used to investigate the aerobic degradation of foam active substance - non-ionic surfactant, APG 2000 UP. The surface aeration using the propeller loop reactor (PLR) guaranteed sufficient $O_2$ for substrate removal and bacteria growth and avoided foam development. Moreover, the cross-flow membrane filtration enabled the separation of the bacteria still loaded with surfactant in the collecting container. The biological degradation of the surfactant with varying hydraulic retention time (HRT) and influent concentration $c_{S0}$ showed high substrate removal of nearly 95% at high volumetric loading rates up to $7.4\;kgCOD\;m^{-3}d^{-1}$ and at sludge loading rates up to 1.8 kgCOD $(kgVSS\;d)^{-1}$ for biomass concentration $c_B\;{\approx}\;constant $. The increasing $c_B$ from 3.4 to $14.5\;gL^{-1}$ TSS respectively sludge retention time (SRT) from 5.1 to 442 d under complete biomass retention by the membrane filtration resulted in high removal of substrate ${\alpha}\;>\;90%$ with reducing excess sludge production.

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

Cross-flow Nanofiltration of PCB Etching Waste Solution Containing Copper Ion (구리이온을 함유한 PCB 폐에칭액의 Cross-flow 나노여과)

  • Park, Hye-Ri;Nam, Sang-Won;Youm, Kyung-Ho
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.272-277
    • /
    • 2014
  • In this study the nanofiltration (NF) membrane treatment of a sulfuric acid waste solutions containing copper ion ($Cu^{+2}$) discharging from the etching processes of the printed circuit board (PCB) manufacturing industry has been studied for the recycling of acid etching solution. SelRO MPS-34 4040 NF membrane from Koch company was tested to obtain the basic NF data for recycling of etching solution and separation efficiency (total rejection) of copper ion. NF experiments were carried out with a cross-flow membrane filtration laboratory system. The permeate flux was decreased with the increasing copper ion concentration in sulfuric acid solution and lowering pH of acid solution, and its value was the range of $4.5{\sim}23L/m^2{\cdot}h$. Total rejection of copper ion was decreased with the increasing copper ion concentration, lowering pH of acid solution and decreasing cross-flow rate. The total rejection of copper ion was more than 70% at the experimental condition. The SelRO MPS-34 4040 NF membrane was represented the stable flux and rejection for 1 year operation.

Comparison study on membrane fouling by various sludge fractions with long solid retention time in membrane bioreactor

  • Sun, Darren Delai;Liu, Shushu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.175-189
    • /
    • 2013
  • A membrane bioreactor (MBR) with sludge retention time (SRT) of 300 days was maintained for over 2 years. Polypropylene microfiltration (MF) membrane with pore size of 0.2 ${\mu}m$ was used in the MBR system. The fouling behaviors of various sludge fractions from the MBR were studied and sub-divided resistances were analyzed. It was observed that $R_{cp}$ was a dominant resistance during the filtration of activated sludge, contributing 63.0% and 59.6% to the total resistance for MBR and sequential batch reactor (SBR) respectively. On the other hand, $R_c$ played the significant role during the filtration of supernatant and solutes, varying between 54.54% and 67.18%. Compared with $R_{cp}$ and $R_c$, $R_{if}$ was negligible, and $R_m$ values remained constant at $0.20{\times}10^{12}m^{-1}$. Furthermore, resistances of all sludge fractions increased linearly with rising mixed liquor suspended solids (MLSS) concentration and growing trans-membrane pressure (TMP), while the relationship was inversed between fraction resistances and cross flow velocity (CFV). Among all fractions of activated sludge, suspended solid was the main contributor to the total resistance. A compact cake layer was clearly observed according to the field emission scanning electro microscopy (FE-SEM) images.

Permeability Reduction Model of Soil-Geotextile System Induced by Clogging (폐색으로 인한 흙/부직포 시스템의 투수능 저하 모델)

  • 이인모;김주현
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.107-116
    • /
    • 2000
  • In this study, the permeability reduction in the soil-filter systems due to clogging phenomenon was evaluated. An extensive research program was performed using two typical weathered residual soils which were sampled at Shinnae-dong and Poi-dong area in Seoul. Two separate simulation tests with weathered residual soil were performed: one was the filtration test(cross-plane flow test); and the other was the drainage material in the field. The compatibility of the sol-filter system was investigated with emphasis on the clogging phenomenon. The hydraulic behaviour of the soil-filter system was evaluated by changing several testing conditions. Also, experimental results of the permeability reduction are compared with the results obtained from the theoretical model which can monitor the spatial variation of the permeability with time.

  • PDF

Novel high performanced and fouling resistant PSf/ZnO membranes for water treatment

  • Sarihan, Adem;Eren, Erdal
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.563-574
    • /
    • 2017
  • Antibacterial effective, high performanced, novel ZnO embedded composite membranes were obtained by blendig ZnO nanoparticles with polysulfone. IR, TG/DTG, XRD and SEM analysis were performed to characterize structure and morphology of ZnO nanoparticles and composite membranes. Contact angle, EWC, porosity and pore structure properties of composite membranes were investigated. Cross-flow filtration studies were performed to investigation of performances of prepared membranes. It was found from the cross section SEM images that ZnO nanoparticles dispersed homogenously up to additive amount of 2% and the membrane skin layer thicknesses increased in the presence of ZnO. Contact angle of pure PSf membranes were reduced from $70^{\circ}$ to $55^{\circ}$ after addition of 4% ZnO. Porosity of composite membrane contains 1% ZnO was higher about 22% than pure PSf membrane. BSA rejection ratio and PWF of 0.5% ZnO embedded composite membrane became 2.2 and 2.3 times higher than pure PSf membrane. It was determined from flux recovery ratios that ZnO additive increased the fouling resistance of composite membranes. Also, the bacterial killing ability of ZnO is well known and there are many researches related to this in the literature. Therefore, it is expected that prepared composite membranes will show antibacterial effect.

A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration- (선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리-)

  • 김인수;김억조;김동근;고성정;안종수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF

Microfiltration of Chlorella sp.: Influence of material and membrane pore size

  • Ahmad, A.L.;Yasin, N.H. Mat;Derek, C.J.C.;Lim, J.K.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.143-155
    • /
    • 2013
  • Four membranes were used to separate Chlorella sp. from their culture medium in cross-flow microfiltration (MF) experiments: cellulose acetate (CA), cellulose nitrate (CN), polypropylene (PP) and polyvinylidenefluoride (PVDF). It was found that the hydrophilic CA and CN membranes with a pore size of 1.2 ${\mu}m$ exhibited the best performances among all the membranes in terms of permeation flux. The hydrophobicity of each membrane material was determined by measuring the angle between the water (liquid) and membrane (solid). Contact angle measurements showed that deionized (DI) water had almost adsorbed onto the surfaces of the CA and CN membranes, which gave $0.00^{\circ}$ contact angle values. The PP and PVDF membranes were more hydrophobic, giving contact angle values of $95.97^{\circ}$ and $126.63^{\circ}$, respectively. Although the pure water flux increased with increasing pore diameter (0.8 < 1.2 < 3.0 ${\mu}m$) in hydrophilic CA and CN membranes, the best performance in term of filtration rate for filtering a microalgae suspension was attained by membranes with a pore size of 1.2 ${\mu}m$. The fouled membrane pore sizes and pore blocking were inspected using a scanning electron microscope (SEM). MF with large pore diameters was more sensitive to fouling that contributed to intermediate blocking, where the size of the membrane pores is almost equivalent to that of cells.

막분리(NF, UF)를 이용한 자연유기물(NOM) 제거에 관한 연구(II) - NF, UF 운전특성과 HAA생성능 제거 -

  • Song, Yang-Seok;Park, Yong-Hun;Jo, Yeong-Gwan;Jo, Jae-Won;Park, Don-Hui
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.334-338
    • /
    • 2003
  • In this study, We evaluated the removal efficiency of natural organic matters(NOM) in the Ultrafiltration(UF) and Nanofiltration(NF) membranes with molecular weight cutoff of 2500(GH), 8000(GM) and 250(HL), respectively. Filtration type was cross-flow filtration. The investigation result about raw water structure was hydrophobic 28%, hydrophilic 53% and transphilic 19%, in conjunction with XAD8/4 resin fractionation method. We were compared with UF(GM, GH) and NF(HL), in operation characteristic. In spite of poor MWCO, GM(8000Da) was superior than GH(2500Da), in the efficiency of total operation. It was showed the NF(HL) 80%, UF(GM) 50%, in the removing efficiency of HAAFP.

  • PDF

Treatment of natural rubber wastewater by membrane technologies for water reuse

  • Jiang, Shi-Kuan;Zhang, Gui-Mei;Yan, Li;Wu, Ying
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • A series of laboratory scale experiments were performed to investigate the feasibility of membrane separation technology for natural rubber (NR) wastewater treatment and reuse. Three types of spiral wound membranes were employed in the cross-flow experiments. The NR wastewater pretreated by sand filtration and cartridge filtration was forced to pass through the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membranes successively. The UF retentate, which containing abundant proteins, can be used to produce fertilizer, while the NF retentate is rich in quebrachitol and can be used to extract quebrachitol. The permeate produced by the RO module was reused in the NR processing. Furthermore, about 0.1wt% quebrachitol was extracted from the NR wastewater. Besides, the effluent quality treated by the membrane processes was much better than that of the biological treatment. Especially for total dissolved solids (TDS) and total phosphorus (T-P), the removal efficiency improved 53.11% and 49.83% respectively. In addition, the removal efficiencies of biological oxygen demand (BOD) and chemical oxygen demand (COD) exceeded 99%. The total nitrogen (T-N) and ammonia nitrogen (NH4-N) had approximately similar removal efficiency (93%). It was also found that there was a significant decrease in the T-P concentration in the effluent, the T-P was reduced from 200 mg/L to 0.34 mg/L. Generally, it was considered to be a challenging problem to solve for the biological processes. In brief, highly resource utilization and zero discharge was obtained by membrane separation system in the NR wastewater treatment.