• Title/Summary/Keyword: cross ratio

Search Result 2,697, Processing Time 0.03 seconds

Correlation between torsional vibration and translational vibration

  • Jeng, V.;Tsai, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.6
    • /
    • pp.671-694
    • /
    • 2002
  • This paper presents theoretical investigation on the cross correlation between torsional vibration ($u_{\theta}$) and translation vibration ($u_x$) of asymmetrical structure under white noise excitation. The formula reveals that the cross correlation coefficient (${\rho}$) is a function of uncoupled frequency ratio (${\Omega}={\omega}_{\theta}/{\omega}_x$), eccentricity, and damping ratio (${\xi}$). Simulations involving acceleration records from fifteen different earthquakes show correlation coefficients results similar to the theoretical correlation coefficients. The uncoupled frequency ratio is the dominating parameter to ${\rho}$; generally, ${\rho}$ is positive for ${\omega}_{\theta}/{\omega}_x$ > 1.0, negative for ${\omega}_{\theta}/{\omega}_x$ < 1.0, and close to zero for ${\omega}_{\theta}/{\omega}_x$ = 1.0. When the eccentricity or damping ratio increases, ${\rho}$ increases moderately for small ${\Omega}$ (< 1.0) only. The relation among $u_x$, $u_{\theta}$ and corner displacement are best presented by ${\rho}$; a simple way to hand-calculate the theoretical dynamic corner displacements from $u_x$, $u_{\theta}$ and ${\rho}$ is proposed as an alternative to dynamic analysis.

Aspect-Ratio Effects and Unsteady Pressure Measurements inside a Cross-Flow Impeller

  • Hirata, Katsuya;Onishi, Yusuke;Nagasaka, Shigeya;Matsumoto, Ryo;Funaki, Jiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.117-125
    • /
    • 2012
  • In the present experimental study, the authors try to clarify the characteristics of the flow around and inside a cross-flow impeller in a typical geometry, over a wide parameter range of an aspect ratio $L/D_2$. In order to eliminate the complicated casing factors, the impeller rotates in open space without any casings. As a result, by using hot wire anemometer measurements and by conventional flow visualisations with a particle image velocimetry technique, the authors show that both the outflow rate and the maximum vorticity attain the maximum for $L/D_2$ = 0.6. In order to investigate the aspect-ratio effect, we further reveal minute fluctuating pressures on an impeller end wall for a singular $L/D_2$ = 0.6. Especially in these pressure measurements, the eccentric vortex is prevented to revolute by the insertion of a tongue, in order to consider the spatial structure of flow more precisely.

Effect of Gas-liquid Ratio on Characterization of Two-Phase Spray Injected into a Cross-flow (횡단유동에 분사된 이유체 분무의 기체 액체비가 분무특성에 미치는 영향)

  • Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Su;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • The effect of two-phase spray injected into subsonic cross-flow was studied experimentally. External-mixing of two-phase spray from orifice nozzle with L/d of 3 was tested with various air-liquid ratio that ranges from 0 to 59.4%. Trajectory of spray and breakup phenomena were investigated by shadowgraph photography. Detailed spray structure was characterized in terms of SMD, droplet velocity, and volume flux using PDPA. Experimental results indicate that penetration length was increased and collision point of liquid jets approached to nozzle exit and distributions of mist-like spray were obtained by increasing air-liquid ratio.

A Novel Vertical Directional Coupler Switch with Switching Operation-Induced, Extinction Ratio-Adjusted, and Extinction Ratio-Enhanced Sections

  • Cho, Sung-Chan;Hong, Hyun-Ha;Yang, Choong-Reol;Choi, Jee-Yon;Kang, Min-Ho;Hwang, Hyun-Yong;Choi, Young-Woo;Kim, Hae-Geun;Jung, Byung-Min;Kim, Boo-Gyoun
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • We propose a novel very short (< $300{\mu}m$) vertical directional coupler switch with high extinction ratios larger than 30 dB. The device consists of a switching operation induced section (SOIS), an extinction ratio adjusted section (ERAS), and an extinction ratio enhanced section (ERES). These are achieved by changing the refractive index of one core. The switching operation is induced by changing the refractive index of one core in the SOIS. The improvement of extinction ratios larger than 30 dB for both the cross and bar states is made by controlling the asymmetry of the refractive indices of both cores in the ERES. Through the ERAS, different extinction ratios between the cross and bar states at the end of the SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of the cores for the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines for high extinction ratios with large tolerances are presented.

  • PDF

PATTERN FORMATION FOR A RATIO-DEPENDENT PREDATOR-PREY MODEL WITH CROSS DIFFUSION

  • Sambath, M.;Balachandran, K.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.16 no.4
    • /
    • pp.249-256
    • /
    • 2012
  • In this work, we analyze the spatial patterns of a predator-prey system with cross diffusion. First we get the critical lines of Hopf and Turing bifurcations in a spatial domain by using mathematical theory. More specifically, the exact Turing region is given in a two parameter space. Our results reveal that cross diffusion can induce stationary patterns which may be useful in understanding the dynamics of the real ecosystems better.

A Fast Normalized Cross Correlation-Based Block Matching Algorithm Using Multilevel Cauchy-Schwartz Inequality

  • Song, Byung-Cheol
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.401-406
    • /
    • 2011
  • This paper presents a fast block-matching algorithm based on the normalized cross-correlation, where the elimination order is determined based on the gradient magnitudes of subblocks in the current macroblock. Multilevel Cauchy-Schwartz inequality is derived to skip unnecessary block-matching calculations in the proposed algorithm. Also, additional complexity reduction is achieved re-using the normalized cross correlation values for the spatially neighboring macroblock because the search areas of adjacent macroblocks are overlapped. Simulation results show that the proposed algorithm can improve the speed-up ratio up to about 3 times in comparison with the existing algorithm.

Formation of PVP- Based Organic Insulating Layers and Fabrication of OTFTs (PVP-기반 유기 절연막 형성과 OTFT 제작)

  • Jang, Ji-Geun;Seo, Dong-Gyoon;Lim, Yong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.16 no.5
    • /
    • pp.302-307
    • /
    • 2006
  • The formation and processing of organic insulators on the device performance have been studied in the fabrication of organic thin film transistors (OTFTs). The series of polyvinyls, poly-4-vinyl phenol(PVP) and polyvinyltoluene (PVT), were used as solutes and propylene glycol monomethyl ether acetate(PGMEA) as a solvent in the formation of organic insulators. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compound. The electrical characteristics measured in the metal-insulator-metal (MIM) structures showed that insulating properties of PVP layers were generally superior to those of PVT layers. Among the layers of PVP series: PVP(10 wt%) copolymer, 5 wt% cross-linked PVP(10 wt%), PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%), the 10 wt% cross-linked PVP(20 wt%) layer showed the lowest leakage current characteristics. Finally, inverted staggered OTFTs using the PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%) as gate insulators were fabricated on the polyether sulphone (PES) substrates. In our experiments, we could obtain the maximum field effect mobility of 0.31 $cm^2/Vs$ in the device from 5 wt% cross-linked PVP(20 wt%) and the highest on/off current ratio of $1.92{\times}10^5$ in the device from 10 wt% cross-linked PVP(20 wt%).

Investigation of Microbial Contamination and Working Environment in University Foodservices (대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

Seismic behavior of steel reinforced concrete cross-shaped column under combined torsion

  • Chen, Zongping;Liu, Xiang
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.407-420
    • /
    • 2018
  • Experiments were performed to explore the hysteretic performance of steel reinforced concrete (SRC) cross-shaped columns. Nine specimens were designed and tested under the combined action of compression, flexure, shear and torsion. Torsion-bending ratio (i.e., 0, 0.14, 0.21) and steel forms (i.e., Solid - web steel, T - shaped steel, Channel steel) were considered in the test. Both failure processes and modes were obtained during the whole loading procedure. Based on experimental data, seismic indexes, such as bearing capacity, ductility and energy dissipation were investigated in detail. Experimental results suggest that depending on the torsion-bending ratio, failure modes of SRC cross-shaped columns are bending failure, flexure-torsion failure and torsion-shear failure. Shear - displacement hysteretic loops are fuller than torque - twist angle hysteretic curves. SRC cross-shaped columns exhibit good ductility and deformation capacity. In the range of test parameters, the existence of torque does not reduce the shear force but it reduces the displacement and bending energy dissipation capacity. What is more, the bending energy dissipation capacity increases with the rising of displacement level, while the torsion energy dissipation capacity decreases.

Characteristics of Optical Current Sensors by Sensor Design

  • Kim, Young-Min;Park, Jung-Hwan;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.80-87
    • /
    • 2007
  • This paper will suggest that the 1 cross orthogonal loop type sensor improves on the orthogonal loop form sensor-head, which is available a calibration of the linear birefringence, when a fiber optic current sensor was composed. An output characteristics of the 1 cross orthogonal loop form, a general closed loop form, the orthogonal loop form are compared by the IEC(International Electrotechnical Commission) 60044-8 standard, and the state of polarization is compared with three forms. As a result, when the closed loop form was changed to the orthogonal loop form, retardation decreased 15.3[%]. When the closed loop form was changed to the 1 cross orthogonal loop type, the retardation decreased 33.8[%]. As a result of the Faraday Effect measurement, the 1 cross orthogonal loop form has the highest output characteristic and the lowest error ratio. It met the 0.5 class of the IEC 60044-8 standard. Thus, in application of the 1cross orthogonal loop form, the possibility to develop high reliability fiber optic current sensors that have a high output and stable error ratio rises is increased.