• Title/Summary/Keyword: cross -sectional image

Search Result 293, Processing Time 0.027 seconds

Impedance Tomography using Internal Current Density Distribution Measured by Nuclear Magnetic Resonance (자기공명촬영상에서 구한 내부 전류밀도를 이용한 임피던스 단층촬영법)

  • Lee, Su-Yeol;U, Eung-Je;Mun, Chi-Ung
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.413-418
    • /
    • 1994
  • In electrical impedance tomography (EIT), we use boundary current and voltage measurements to provide the information about the cross-sectional distribution of electrical impedance or resistivity One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.7T NMR machine. We implemented a resistivity image reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the image reconstruction algorithm and furture direction of the research.

  • PDF

Comparision of 3-D Geometrical Modelling of the Lumbar Spine Using Parameterized and Cross-sectional CT Image Reconstruction Method (요추에 있어서 파라미터 기법과 단면CT영상을 이용한 3차원 형상 모델링의 비교)

  • Kim, S.M.;Kim, S.J.;Tack, K.R.;Kim, N.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.159-160
    • /
    • 1998
  • In this study, a three-dimensional geometrical parameterized finite element modeling of the lumbar spine is compared with the 3-D reconstruction model from 2-D CT image. feasibility and accuracy of the parameterized modeling method is evaluated compared with conventional 3-D reconstruction method from 2-D CT image.

  • PDF

Influencing Factors of Sexual Intimacy and Satisfaction among Women within 1 Year after Mastectomy (유방절제술 후 1년 이내 여성의 성적 친밀감과 성만족에 영향을 미치는 요인)

  • Kim, Sunyoung;Ahn, Sukhee
    • Women's Health Nursing
    • /
    • v.25 no.2
    • /
    • pp.219-231
    • /
    • 2019
  • Purpose: The purpose of this study was to identify the levels of body image, sexual intimacy, and sexual satisfaction, and to explore factors affecting sexual intimacy and satisfaction among women within one year of mastectomy. Methods: The present study was a cross-sectional survey and involved 101 women who had undergone mastectomy at a University hospital of D city, Korea. Measurement included the scales of body image, sexual intimacy, and sexual satisfaction. Results: Mean age of the subjects was 51 years. Scores of the body image, sexual intimacy, and sexual satisfaction were 59.62, 90.69, and 69.04, respectively. Body image, sexual intimacy, and sexual satisfaction were significantly related to each other. Sexual intimacy was higher when women were of young age (${\beta}=-.32$), had a shorter period since surgery (${\beta}=-.24$), and with higher levels of body image (${\beta}=.37$). Sexual satisfaction was higher when women had higher levels of body image (${\beta}=.19$) and greater levels of sexual intimacy (${\beta}=.74$). Conclusion: Higher levels of body image and greater levels of sexual intimacy were identified as the significant factors influencing sexual satisfaction among these women. Future research with a mixed-method research is needed to gain a deep understanding of the sexuality between women and their husbands.

Analysis of the image composition speed of RT and TPSM algorithms (RT과 TPSM 알고리즘의 영상구성 속도 분석)

  • Jin-Seob Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.139-143
    • /
    • 2023
  • In this paper, compared to the RT algorithm that constitutes CT images, the TPSM algorithm available in the conical CB-CT system was applied to enable 3D CT image configuration faster than the existing RT, and the image speeds of the two algorithms were compared and analyzed. To this end, the TPSM algorithm available in the conical CB-CT system was applied to enable real-time processing in 3D CT image composition. As a result of the experiment, it was found that the cross-sectional image constructed using TPSM decreases the quality of the image slightly by empty pixels as the distance from the center point increases, but in the case of TPSM rotation-based methods, the image composition speed is far superior to that of the RT algorithm.

Body Image, Self Esteem, and Health related Quality of Life in Patients with Crohn's Disease (크론병 환자의 신체상, 자아존중감 및 건강 관련 삶의 질)

  • Lee, Young Jin;Oh, Eui Geum
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.4
    • /
    • pp.383-392
    • /
    • 2014
  • Purpose: The purpose of this study was to describe the degrees of body image, self esteem and Health Related Quality Of Life (HRQOL), and to identify factors related to these variables in patients with Crohn's disease. Methods: A descriptive cross sectional survey design was used. The 148 participants were the patients with Crohn's disease, recruited conveniently from one metropolitan hospital located in Seoul, Korea. The collected data were analyzed with SPSS/WIN program. Results: Patients with severe illness activity reported significantly lower body images than those of the others. Education levels and working states affected self-esteem positively, while the number of operations and illness activity affected self-esteem negatively. Hospitalization and illness activity affected HRQOL negatively. Body image, self esteem, and HRQOL were positively correlated to each other with statistical significance. Illness activity was a common factor to affect body image, self esteem, and HRQOL. Body image was an influential factor on HRQOL as well as illness activity in patients with Crohn's disease. Conclusion: As a result, this study suggested a necessity for developing an intervention study to lower the illness activity and heighten the body image among the patients with Crohn's disease.

Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

  • Torres, Andres;Jacobs, Reinhilde;Lambrechts, Paul;Brizuela, Claudia;Cabrera, Carolina;Concha, Guillermo;Pedemonte, Maria Eugenia
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment (3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상)

  • Jeong, Woo-Chul;Kim, Young-Tae;Minhas, Atul S.;Kim, Hyung-Joong;Lee, Tae-Hwi;Kang, Byeong-Teck;Park, Hee-Myung;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

Numerical analysis of the thermal behaviors of cellular concrete

  • She, Wei;Zhao, Guotang;Yang, Guotao;Jiang, Jinyang;Cao, Xiaoyu;Du, Yi
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.319-336
    • /
    • 2016
  • In this study, both two- and three-dimensional (2D and 3D) finite-volume-based models were developed to analyze the heat transfer mechanisms through the porous structures of cellular concretes under steady-state heat transfer conditions and to investigate the differences between the 2D and 3D modeling results. The 2D and 3D reconstructed pore networks were generated from the microstructural information measured by 3D images captured by X-ray computerized tomography (X-CT). The computed effective thermal conductivities based on the 2D and 3D calculations performed on the reconstructed porous structures were found to be nearly identical to those evaluated from the 2D cross-sectional images and the 3D X-CT images, respectively. In addition, the 3D computed effective thermal conductivity was found to agree better with the measured values, in comparison with the 2D reconstruction and real cross-sectional images. Finally, the thermal conductivities computed for different reconstructed porous 3D structures of cellular concretes were compared with those obtained from 2D computations performed on 2D reconstructed structures. This comparison revealed the differences between 2D and 3D image-based modeling. A correlation was thus derived between the results of the 3D and 2D models.

Effects of Fiber Wall Thickness on Paper Properties Using CLSM (CLSM을 이용한 고해과정 중 섬유벽 두께 변화의 종이 특성 영향 분석)

  • 김서환;박종문;김철환
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • Refining in papermaking plays an important role in changing fiber properties as well as paper properties. The major effects of refining on pulp fibers are internal and external fibrillation, fiber shortening, and fines formation. Many workers showed that internal fibrillation of the primary refining effects was most influential in improving paper properties. In particular, refining produces separation of fiber walls into several lamellae, thus causing fiber wall swelling with water penetration. This leads to the increase of fiber flexibility and of fiber-to-fiber contact during drying. If the fibers are very flexible, they will be drawn into close contact with each other by the force of surface tension as the water is removed during the drainage process and drying stages. In order to study the effect of fiber wall delamination on paper properties, cross-sectional image of fibers in a natural condition had to be generated without distortion. Finally, it was well recognized that confocal laser scanning microscope (CLSM) could be one of the most efficient tool for creating and quantifying fiber wall delamination in combination with image analysis technique. In this study, the CLSM could be used not only to observe morphological features of transverse views of swollen fibers refined under low and high intensity, but also to investigate the sequence of fiber wall delamination and fiber wall breakage. From the CLSM images, increasing the specific energy or refining decreased the degree of fiber collapse, fiber cross-sectional area, fiber wall thickness and lumen area. High intensity refining produced more external fibrillation.

  • PDF

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF