• Title/Summary/Keyword: critical magnetic field

Search Result 358, Processing Time 0.028 seconds

Magnetic Field and Electric Field Generated in an HTS Tape of a High Temperature Superconducting Magnet (고온 초전도 마그넷의 선재에서 발생되는 자장과 전계 해석)

  • Kim, Young-Min;Ku, Myung-Hwan;Cha, Guee-Soo;Jeon, Chang-Wan;Paik, Kyoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.753-758
    • /
    • 2011
  • Magnetic field and Electric field of High Temperature Superconducting magnet are very important to analysis of superconducting magnet. The maximum perpendicular magnetic field was applied to the outermost pancake windings. The critical current of all the magnet windings is limited by the critical current of the outermost pancake windings. The E-J relation was used to determine the critical current, and an evolution s trategy was adopted for the optimization of gap length between each pancake windins. The results of calculations show that the critical current and the central magnetic field and uniformity increased by 82.6% and 31.6% and 50.8%, respectively, for a magnet consisting of ten pancake windings. This paper did an analysis the cause of increase the critical current and central magnetic field and uniformity in no gap and optimal gap model.

Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

  • Kim, J.;Lee, W.S.;Jin, H.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

Estimation of the Magnetic Field and the Critical Current of HTS BSCCO Pancake Windings (고온초전도 BSCCO 팬케이크 권선에 인가되는 자장과 임계전류의 산정)

  • Koo, Myung-Hwan;Kang, Myung-Hun;Lee, Hee-Joon;Cha, Guee-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1970-1975
    • /
    • 2008
  • Critical current of the superconducting machines is limited by the magnetic field. When the magnetic field is not uniform, it is difficult to estimate the magnetic field and the critical current. This paper proposed a method for the estimation of the magnetic field and the critical current of the HTS pancake windings which can be used to generate the high field magnet. A parameter which was needed to calculate the critical current of a BSCCO magnet with 10 pancake windings was obtained by the experiment. Test which was carried out by using single pancake winding and magnet consisting of 10 pancake windings shows the proposed method can be an effective method for the estimation of the critical current of pancake windings.

Analysis of Magnetic Field of Superconducting Winding According to the Changed Damper Thickness and Material (댐퍼의 두께와 재질 변화에 따른 초전도 선재에 미치는 자장특성 분석)

  • Jeong, Jae-Sik;Lee, Sang-Ho;Hong, Jung-Pyo;Jo, Young-Sik
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.5-8
    • /
    • 2012
  • Superconducting windings of synchronous machine have to be operated in below the critical temperature, critical current density and critical magnetic field. If one of these characteristics does not satisfied, then the quench occurred in superconducting winding. Especially the armature current dramatically increased as the superconducting generator is short-circuited at the rated load condition and magnetic field in field winding increased due to the armature current. Therefore, damper is required to reduce the magnetic field of field winding which increases reliability of the superconducting generator. Damper dimension can be decided by time constant[1-2]. In this paper the basic model is high-power and low-speed superconducting generator. Damper time constant was calculated from the changed damper thickness and material. Magnetic flux of field coil at the basic model and changed damper time constant model is analyzed.

Critical Current Degradation Analysis in HTS Pancake Coil due to Self Field Effects

  • Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.68-72
    • /
    • 1999
  • Since the discovery of high Tc superconductors, great efforts have been focused to develop high performance HTS magnets for the ultimate applications to power system devices. Magnet designers, however, have had difficulties in the estimation of the maximum operating current of the designed magnet from the tested short sample data, due to the degradation of the critical current density in the magnet. Similar story applies to the HTS electrical bus bar. It has been found that the critical current of Bi-2223 stacked tapes is much less than the total summation of critical currents of each tape, which is mainly attributed to the self magnetic fields. Furthermore, since the critical current degradation of Bi-2223 tape is greater in the normal magnetic field (to the tape surface) than in the parallel one, detailed magnetic field configurations are required to reduce the self field effects. In this paper, we calculate the self field effects of a stacked conductor, defining self field factors of normal and parallel magnetic fields to the tape surface. Finally, the critical current degradations in the HTS magnet are explained by the introduced self field factors of the stacked conductor.

  • PDF

High field HTS insert coils : Status and key technical issue

  • Schwartz, Justin
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.22-22
    • /
    • 2000
  • The discoveries of high temperature superconductors received great attention due to their high critical temperatures. These materials also exhibit extremely high critical magnetic fields and high critical current density at low temperature, high magnetic field. Thus, they are the most promising materials for superconducting magnets above 20 T. In this talk, progress in the development of HTS materials and insert coils at the National High Magnetic Field Laboratory will be reviewed. In 1999, a Bi-2212 stack of double pancakes generated 3 T in a 19 T background field. These results will be reviewed in terms of implications for future systems. Individual double pancakes of Bi-2223 have also been tested and their performance will also be discused. The present goal of a 57 system will be presented and the key technical requirements for larger, higher field systems will be addressed. It will be shown that in addition to increased critical current density, improved mechanical performance (stain resistanced) is necessary for high field systems. Furthemore, improvements in the conductor n-value will improve prospects for operational systems.

  • PDF

Non-contact critical current measurement using hall probe (Hall probe를 이용한 비접촉 임계전류 측정)

  • Kim, Ho-Sup;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Kim, Tae-Hyung;Ko, Rock-Kil;Ha, Hong-Soo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.7-8
    • /
    • 2009
  • Non-contact critical current measurement apparatus was developed using hall probe which measures the magnetic field distribution across the width of superconducting tape. The hall probe consists of 7 independent hall sensors which lie in a line 600 ${\mu}m$. The difference between maximum and minimum magnetic field in the magnetic filed distribution is a main parameter to determine the critical current. As preliminary research, we calculated the magnetic field intensity at the middle sensor, which is a minimum magnetic field and generated by the circular shielding current modeled by Bean model. We confirmed that there are some parameters that affect on the minimum magnetic field; the distance between superconducting layer and hall sensor, the width of superconducting tape, and the critical current distribution across the width of superconducting tape. Among these parameters, the distance between superconducting layer and hall sensor highly influences on the minimum magnetic field.

  • PDF

Angular distributions of the critical current of ReBCO coated conductors in magnetic field up to 5T

  • Mineev, Nikolay A.;Rudnev, Igor A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.6-9
    • /
    • 2015
  • For many applications of $ReBa_2Cu_3O_{7-x}$ (ReBCO) tapes it is needed to know the anisotropic properties of the used conductor in a broad range of magnetic field. In this paper we present the results of transport measurements on the SuNAM tape (GdBaCuO) with the rotation of the sample in magnetic fields up to 5 T in liquid nitrogen. The critical current over the magnetic field orientation ($I_c({\theta})$) curves demonstrate the appearance of distinct second peak around c-axis in low fields. This peak almost vanishes in the fields over 3 T. The evolution of the ab-peak form is also presented: the peak consistently reduces its height with the magnetic field going up and in the high fields the shoulders rise, changing the type of the distribution. To describe experimental curves the vortex path model was applied to the angular distributions of the critical current in magnetic field. Good agreements of the experimental data with the analytical expressions were obtained that confirm the vortex path model approach.

A study on the magnetic properties of high Tc superconductor $Y_{1-x}Yb_xBa_2Cu_3FyOy$ (고온 초전도체 $Y_{1-x}Yb_xBa_2Cu_3FyOy$의 자기적 성질에 관한 연구)

  • 김재욱;김채옥
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.578-583
    • /
    • 1996
  • The magnetic properties have been investigated for the system of $Y_{1-x}$Yb$_{x}$Ba$_{2}$Cu$_{3}$F$_{y}$O$_{y}$ with x=0.0, 0.1, 0.2, 0.3, 0.4 and 0.5. In the magnetic hysteresis measurements, the values of the magnetic critical current densities are in the range of 10$^{4}$-10$^{5}$ A/cm$^{2}$ at the maximum external field 1.4 T. The upper critical field is over 100 T. The critical current density is estimated by the magnetization width .DELTA.M through the Bean critical state model. As the field strength is increased, the .DELTA.M diminishes slowly. The .DELTA.M for the fluorinated sample also decreases slowly with increasing field. It is considered that the large J, value results from this type is due to enhanced pinning center in grain boundary.y.ary.y.

  • PDF

Experimental Study for Ferrofluid Couette Flow between Two Coaxial Spheres (동축 구 사이의 자성 유체의 Couette 유동에 관한 연구)

  • 구도연;하옥남;전운학
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 1996
  • This study investigated torque characteristics for Couette flow experimentally under circumstaces that ferrofluids were between two coaxial spheres. Torque measurement was obtained for the situation where the inner sphere was rotating while the outer sphere was kept stationary. The magnetic field was imposed on the fluid, using a bar magnet which was inserted in the inner sphere. In the laminar flow region the torque increase when the magnetic field is applied and the critical Reynolds number is increased. However, in the transition regime, the effect of the magnetic field on the torque characteristics decrease as Reynolds number increases. The value of torque were the same as those of glycerine solution beyond the cirtical Reynolds number. We also made experimental equation which could obtain coefficient of torque within critical Reynolds number in terms of sphere spacing Reynolds number and magnetic properties of ferrofluid.

  • PDF