• Title/Summary/Keyword: critical load

Search Result 1,590, Processing Time 0.027 seconds

Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame (중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험)

  • 이한선;우성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.241-252
    • /
    • 1998
  • The objective of the research stated herein is to observe the actual responses of a low-rise nonseismic moment-resisting reinforced concrete frame subjected to varied levels of earthquake ground motions. First, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used and the model was manufactured according to the similitude law. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelations (PGAs) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The lateral accelerations and displacements at each story and local deformations at the critical reginos of the structure were measured. The base shear was measured by using self-made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the change in the natural period and damping ratio of the model. The test data on the global and local behaviors are interpreted. The model showed the linear elastic behavior under the Taft N21E motion with the PGA if 0.12g, which represents the design earthquake in Korea. The maximum base shear was 1.8tf, approximately 4.7 times the design base shear. The model revealed fairly good resistance to the higher level of earthquake simulation tests. The main components of its resistance to the high level of earthquakes appeared to be 1) the high overstrength, 2) the elongation of the fundamental period, and 3) the minor energy dissipation by inelastic deformations. The drifts of the model under these tests were approximately within the allowable limit.

A Study on 8-Stage Loading Method of the Scaffolding Module for LNG Carriers (LNG 운반선 비계 모듈의 8단 탑재 방안 연구)

  • Shin, Sang-Hoon;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.78-85
    • /
    • 2020
  • The scaffolding system, which is a construction workbench of the cargo containment for a membrane LNG carrier, is a large truss structure composed of various members. To shorten the installation period and process of the scaffolding system, it is effective to enlarge the mounting unit from the existing two stages to eight stages. Owing to the increase in lifting load according to the large size of the module, the stresses around the pin and hole will be increased significantly. In this study, a tensile strength test and contact stress analysis were performed to confirm the structural safety. The relatively large hole deformation was observed visually near the average load generated in the vertical pipe at the top through tensile strength tests. A contact stress calculation confirmed the stress distribution around the hole. The contact problem was dealt with in terms of the Herzian contact stress. The possibility of 8-stage loading was examined by comparing the yield strength and contact stresses of failure critical locations. As a result, the 8-stage loading method of the existing scaffolding material was inadequate, and a new loading method with proper safety is proposed.

One-Chip Multi-Output SMPS using a Shared Digital Controller and Pseudo Relaxation Oscillating Technique (디지털 컨트롤러 공유 및 Pseudo Relaxation Oscillating 기법을 이용한 원-칩 다중출력 SMPS)

  • Park, Young-Kyun;Lim, Ji-Hoon;Wee, Jae-Kyung;Lee, Yong-Keun;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.148-156
    • /
    • 2013
  • This paper suggests a multi-level and multi-output SMPS based on a shared digital logic controller through independently operating in each dedicated time periods. Although the shared architecture can be devised with small area and high efficiency, it has critical drawbacks that real-time control of each DPWM generators are impossible and its output voltage can be unstable. To solve these problems, a real-time current compensation scheme is proposed as a solution. A current consumption of the core block and entire block with four driver buffers was simulated about 4.9mA and 30mA at 10MHz switching frequency and 100MHz core operating frequency. Output voltage ripple was 11 mV at 3.3V output voltage. Over/undershoot voltage was 10mV/19.6mV at 3.3V output voltage. The noise performance was simulated at 800mA and 100KHz load regulation. Core circuit can be implemented small size in $700{\mu}m{\times}800{\mu}m$ area. For the verification of proposed circuit, the simulations were carried out with Dong-bu Hitek BCD $0.35{\mu}m$ technology.

The Estimation and Comparison of Flexural Crack Width Considering Bonding Characteristics in Reinforced Concrete Members (부착특성을 고려한 철근콘크리트 부재의 휨 균열폭 산정 및 비교)

  • Ko, Won-Jun;Min, Byung-Chul;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.579-588
    • /
    • 2006
  • In recent years, the availability of high-strength reinforcing and prestressing steels leads us to build economically and efficiently designed concrete structural members. One of critical problems faced to the structural engineers dealing with these types of structural member is controls of crack width that is used as a criterion for the serviceability in the limit state design. Especially, flexural cracking must be controlled to secure the structural safety and to improve the durability as well as serviceability of the load carving members. The proposed method utilizes the results of pure tension test in which tensile loads are applied both side of specimen, done by Ikki. The bond characteristics of deformed reinforcing bar under pure tension is considered by the area of concrete and rib area. The results of proposed method are compared with the test data and the results show that the proposed method can take into account the dimensions, variation of sectional properties, and direction of reinforcing and gives more accurate maximum bond stress and corresponding relative slip than the existing methods. the characteristics of bonding is considered by using dimensionless slip magnitude and effective reinforcement ratio. The validity of the proposed equation is verified by test experimental data.

Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators (진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교)

  • Han, Beom-Hui;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;You, In-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.389-394
    • /
    • 2012
  • In this study, based on IEC 60601-2-54 standard load conditions presented in the limited interval over the air kerma at the absolute linearity closely evaluated by measuring the X-ray results were as follows: 10 units targeted all Diagnostic X-ray generating device (DR) presented in the IEC 60601-2-54 standard linearity of air kerma emerged as inappropriate, the general evaluation of the dose linearity from four in the top 50% and 80 kVp % of the two measurement series were as irrelevant all the rest from six of the top tube voltage of 50% and 80% of the two measurement series, appeared in all suitable. Presented in IEC 60601-2-54 standard dose linearity testing and conventional linearity tests showed many differences. IEC 60601-2-54 standard linearity in the proposed international standards of air kerma is the recommendation of the existing dose linearity considerably more feasible, and to quantify the amount of radiation as the standard suggested by the standard IEC 60601-2-54 air kerma of a diagnostic X-ray imaging device linearity performance management is considered key elements in the critical appraisal.

Software Architecture for Implementing the Grid Computing of the High Availability Solution through Load Balancing (고가용성 솔루션 구축을 위한 그리드 측면에서의 소프트웨어 아키텍처를 통한 로드밸랜싱 구현)

  • Lee, Byoung-Yup;Park, Jun-Ho;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.26-35
    • /
    • 2011
  • In these days, internet environment are very quickly development as well on-line service have been using a online for the mission critical business around the world. As the amount of information to be processed by computers has recently been increased there has been cluster computing systems developed by connecting workstations server using high speed networks for high availability. but cluster computing technology are limited for a lot of IT resources. So, grid computing is an expanded technology of distributed computing technology to use low-cost and high-performance computing power in various fields. Although the purpose of Grid computing focuses on large-scale resource sharing, innovative applications, and in some case, high-performance orientation, it has been used as conventional distributed computing environment like clustered computer until now because grid middleware does not have common sharable information system. In order to use grid computing environment efficiently which consists of various grid middleware, it is necessary to have application-independent information system which can share information description and services, and expand them easily. This paper proposed new database architecture and load balancing for high availability through Grid technology.

Behavior of Hybrid Stud under Compressive Load (복합스터드의 압축 좌굴 거동)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.609-619
    • /
    • 2004
  • An investigation was conducted on the activities around Europe in order to solve the problem of the thermal bridging of steel studs, which had caused a significant disadvantage. This study included the following: diminishing the contact area between the studs and the sheathing, lengthening the heat transfer route, replacing the steel web with a less conductive material, and placing foam insulation in locations where the thermal shorts are most critical. Although energy efficiency is usually the focus of such foreign cases because their stud application is mostly limited to low-rise residential buildings, both structural and thermal performance are taken into consideration in this study because these target middle-story buildings. A hybrid stud composed of steel and polymer was also developed. This hybrid stud, which is 150 SL in size, is made of a galvanized steel sheet (SGC58) and a glass fiber reinforced polymer (GFRP) withepoxy bonding. A total of 32 specimens were manufactured. Its parameters comprise two types of connection detail,s: the thickness of steel (1.0mm and 1.2mm) and of the GFRP (4mm-4ply and 6mm-6ply), and the ratio of the length to the depth (L/D = 3, 6, 9, 12). Steel stud specimens with the same conditions were compared to the hybrid stud. The test revealed that in the case of the steel specimen with a thickness of 1.0mm, the maximum load of hybrid studs increased an average of 1.62 times comparedto that of the steel stud. In the case of the steel specimen with a thickness of 1.2mm, on the other hand, the average increase was 1.46times. All specimens showed full composite action until the collapse.

Low Temperature Structural Tests of a Composite Wing with Room Temperature-Curing Adhesive Bond (상온접합 본딩이 있는 복합재 날개의 저온 구조시험)

  • Ha, Jae Seok;Park, Chan Yik;Lee, Kee Bhum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.928-935
    • /
    • 2015
  • This paper presents low temperature structural tests of a UAV wing which has room temperature-curing adhesive bond. The wing structure is made of carbon fiber reinforced composites, and the skins are bonded to the inner structures (such as ribs and spars) using room temperature-curing adhesive bond. Also, to verify damage tolerance design of the wing structure, barely visible impact damages are intentionally created in the critical areas. The attachment fittings of the wing are fixed in a specially designed chamber which can simulate the low temperature environments of the operating altitudes. The test load is applied by hydraulic actuators which are placed outside the chamber. The structural tests consist of strain survey tests and a durability test for 1-life fatigue load spectrum. During the tests, strains of major parts are measured by strain gauges and FBG sensors. The change of the initial impact damages is also monitored using piezoelectric sensors. The 1-life damage tolerance of the composite structure is verified by the structural tests under the simulated environments.

The Deformation and Breaking Load of the Fishing Hook by the Tensile Test (인장시험에 의한 낚시의 변형과 파단하중)

  • KO Kwan-Soh;KIM Yong-Hae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.269-275
    • /
    • 1981
  • The fishing hooks were tested for breaking and unbending due to plastic deformation of the material. Study of tensile test is not complicated, but has not even worked out fully enough, especially when the test specimen is subjected to plastic deformation. The fishing hook is subjected to unbending stress and the critical section is a Point which is furthest from the line of action of the forces. The dynamic force of fish during jerks depends on their speed of movement and body weight, the kinetic energy corresponding to it and also on the rlastic displacement of the rigging which absorb the energy. Six kinds of hook were tested by the dynamometer under tensile speed 290mm/min (subscript s) and 780mm/min (subscript f). According to their results, the breaking load(B: kg) can be induced with the formula $B={\alpha}wd^2+\beta$ where w(mm) is the distance between the barb base and the lower shank and d(mm) is diameter. The coefficients of the formula for the round hooks(R) and the angular hooks(A) are approximately as follows: $$R:\;\alpha_{s}=0.5,\;\beta_{s}=1.6,\;\alpha_{f}=0.4,\;\beta_{f}=1.4$$ $$A:\;\alpha_{s}=1.1,\;\beta_{s}=2.0,\;\alpha_{f}=1.0,\;\beta_{f}=0.9$$ The ratio of $B_{f}\;to\;B_{s}$ is corresponding to 0.8. The ratio of deformation(X) that is moved distance of barb base at break to the distance(H) between head base and barb base is about $50\%$. Further study should be carried out on the subject of impact and fatigue test under the same condition which is exerted force by the hooked fish.

  • PDF

A Study on the Behavior of Deformation in Soft Soils Subjected to Lateral Flow (측방유동을 받는 연약지반의 변형거동에 관한 연구)

  • 안종필;홍원표
    • Geotechnical Engineering
    • /
    • v.10 no.2
    • /
    • pp.25-40
    • /
    • 1994
  • In order to investigate behavior of lateral flow by plasticity of soils and construction control due to it, in the case of unsymmetrical surcharge load on the soft soils, we examine the existing theoretical background, and compared and analysed the experimental results by model test. After model test fabricated by model test apparatus, which made full remolding samples of soft soils, we observed the state of behavior for deformation with increasing load step to constant time interval. The critical surcharge and ultimate capacity showed tendency to approach to the proposed value of Jaky and Meyerhof, and the lateral flow pressure of which the maximum value was acted on the depth calculated by z/H=0.26+1.71cu and one third value of the maximum lateral flow pressure acted on the ground surface, approach the trapezoid distribution And maximum lateral flow pressure will be calculated by proposed equation of Hong or simple equation which($\alpha=0.4$) the flow pressure coefficient . of proposed equation by Tschebotarioff exchanged to($\alpha=K_0$) . Basides, the failure surcharge by [(q/$y_m$)-q] and [$S_y-(y_m/S_y)$] showed the smaller than ultimate bearing capacity, especially failure criteria line of control diagram of [$S_y(y_m/S_y)$] will be calculated by following equation. $S_y.=3.15exp[-0.58(y_m/S_y)$

  • PDF