• 제목/요약/키워드: critical flux

검색결과 596건 처리시간 0.032초

Modeling Of Critical Flux Conditions In Crossflow Microfiltration

  • Kim, Su-han;Park, Hee-kyung
    • Water Engineering Research
    • /
    • 제1권2호
    • /
    • pp.119-127
    • /
    • 2000
  • In the process of crossflow microfiltration, a deposit of cake layer tends to form on the membrane, which usually controls the performance of filtration. It is found, however, that there exist a condition under which no deposit of cake layer is made. This condition is called the sub-critical flux condition, and the critical flux here means a flux below which a decline of flux with time due to the deposit of cake layer does not occur. In order to study the characteristics of the critical flux, a numerical model is developed to predict the critical flux condition, and is verified with experimental results. For development of the model, the concept of effective particle diameter is introduced to find a representative size of various particles in relation to diffusive properties of particles. The model is found to be in good match with the experimental results. The findings from the use of the model include that the critical flux condition is determined by the effective particle diameter and the ratio of initial permeate flux to crossflow velocity.

  • PDF

An Experimental Study of Critical Heat Flux in Non-uniformly Heated Vertical Annulus under Low Flow Conditions

  • Chun, Se-Young;Moon, Sang-Ki;Baek, Won-Pil;Chung, Moon-Ki;Masanori Aritomi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1171-1184
    • /
    • 2003
  • An experimental study on critical heat flux (CHF) has been performed in an internally heated vertical annulus with non-uniform heating. The CHF data for the chopped cosine heat flux have been compared with those for uniform heat flux obtained from the previous study of the authors, in order to investigate the effect of axial heat flux distribution on CHF. The local CHF with the parameters such as mass flux and critical quality shows an irregular behavior. However, the total critical power with mass flux and the average CHF with critical quality are represented by a unique curve without the irregularity. The effect of the heat flux distribution on CHF is large at low pressure conditions but becomes rapidly smaller as the pressure increases. The relationship between the critical quality and the boiling length is represented by a single curve, independent of the axial heat flux distribution. For non-uniform axial heat flux distribution, the prediction results from Doerffer et al.'s and Bowling's CHF correlations have considerably large errors, compared to the prediction for uniform heat flux distribution.

분무냉각에 있어서 임계열유속 상관식에 관한 연구 (Study on Correlation of Critical Heat Flux in Spray Cooling)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제23권3호
    • /
    • pp.109-113
    • /
    • 2018
  • The critical heat flux of spray cooling were measured on the test surface of 10 mm diameter made by stainless steel. The experiments were carried out for the droplet-flow-rate of $0.00002{\sim}0.003m^3/(m^2s)$ and liquid subcooling temperature of $40{\sim}75^{\circ}C$. Experimental results showed that the critical heat flux of spray cooling increased remarkably with the increase of droplet-flow-rate. Meanwhile, the effect of liquid subcooling on critical heat flux of spray cooling appeared weakly under the present experimental conditions. In additions, correlation between the dimensionless critical heat flux and Weber number based on droplet-floe-rate was developed for experimental results.

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

MBR공정의 플럭스 향상 기술에 관한 연구

  • 노성희;김선일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.145-148
    • /
    • 2002
  • 막 생물반응기를 이용하여 일정한 TMP 와 일정한 플턱스 여과방식에 따른 실험을 수행한 결과, 일정한 TMP 에서보다 일정 한 투과 플럭스에서 여과하는 것이 여과의 초기 단계동안 과도한 오염을 피할 수 있으므로 바람직하다는 것을 확인하였다. 투과 플럭스를 고정시킨 실험에서 속도에 대한 임계 플럭스 증가 간격은 선형적이었으며, supra-critical zone 과 sub-critical zone 의 두 지대로 구분되었다. 막 생물반응기는 화학적 세정 없이 장 기간 운전되어야하므로 TMP를 고정시키는 깃보다 플럭스를 고정시켜 운전하는 것이 효과적이여, 최적운선조건은 sub-critical zone 경계층 위, 임계플렉스 바로 아래상태임을 알 수 있었다.

  • PDF

Experimental Investigation on Critical Heat Flux in Bilaterally Heated Annulus with equal heat flux on both sides

  • Miao Gui;Junliang Guo;Huanjun Kong;Pan Wu;Jianqiang Shan;Yujiao Peng
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3313-3319
    • /
    • 2023
  • A phenomenological study on CHF in a bilaterally heated annulus with equal heat flux on both sides was experimentally performed. The working fluid of the present test was R-134a. Variation characteristics of CHF and transition of CHF occurrence location were investigated under different pressure, mass flux and quality conditions. With the increase of critical thermodynamic quality, it was found that CHF first occurred on the outer surface of the annulus, then simultaneously occurred on both sides, and finally occurred on the inner surface at relatively high critical quality. After the CHF location transitioned to the inner rod, the sharp fall of CHF in the limiting critical quality region was observed. The critical quality corresponding to the CHF location transition decreased with the increase of mass flux and pressure. Besides, CHF in tube, internally heated, externally heated and bilaterally heated annuli were compared under the same hydraulic diameter conditions. The present study is conducive to improving the understanding of complicated CHF mechanism in bilaterally heated annulus, enriching the experimental database, and providing evidence for developing accurate CHF mechanism model for annuli.

CRITICAL EXPONENTS FOR A DOUBLY DEGENERATE PARABOLIC SYSTEM COUPLED VIA NONLINEAR BOUNDARY FLUX

  • Mi, Yongsheng;Mu, Chunlai;Chen, Botao
    • 대한수학회지
    • /
    • 제48권3호
    • /
    • pp.513-527
    • /
    • 2011
  • The paper deals with the degenerate parabolic system with nonlinear boundary flux. By constructing the self-similar supersolution and subsolution, we obtain the critical global existence curve. The critical Fujita curve is conjectured with the aid of some new results.

CaO-SiO2-Al2O3-MgO계 용접 플럭스계의 점성에 미치는 MgO의 영향성에 관한 연구 (Effect of MgO on the Viscous Behavior of CaO-SiO2-Al2O3-MgO Welding Flux System)

  • 김혁;정은진;전영덕;민동준
    • 대한금속재료학회지
    • /
    • 제47권2호
    • /
    • pp.114-120
    • /
    • 2009
  • The viscosities of $CaO-SiO_2-Al_2O_3-MgO$ flux were measured under the condition of $CaO/SiO_2=1.0-1.3$ and 5-20 wt%MgO. Submerged arc welding flux with $5wt%Al_2O_3$ content had the lowest critical temperature and widest solid-liquid coexisting region at about 5 wt%MgO. It indicateds that both critical temperature and viscosity depend on the kind of primary phase of molten flux. Viscous behavior of the molten flux at 1773 K was analyzed in the view of silicate structure changed by FT-IR spectroscopy. Based on the critical temperature and the behavior of viscosity at a fixed temperature, it could be proposed that the contents of MgO and $Al_2O_3$ in SAW flux show a pronounced effect on preventing contamination in maintaining the liquid phase flux after welding process.

임계 열유속 근방까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Upto Critical Heat flux)

  • 박기정;정동수
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.571-580
    • /
    • 2008
  • In this work, pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal smooth square surface of 9.52 mm length. Tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from $10\;kW/m^2$ to critical heat flux of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and by thermocouples in the liquid pool. Test results show that pool boiling HTCs of refrigerants increase as the heat flux and vapor pressure increase. This typical trend is maintained even at high heat fluxes above $200\;kW/m^2$. Zuber's prediction equation for critical heat flux is quite accurate showing a maximum deviation of 21% for all refrigerants tested. For all refrigerant data up to the critical heat flux, Stephan and Abdelsalam's well known correlation underpredicted the data with an average deviation of 21.3% while Cooper's correlation overpredicted the data with an average deviation of 14.2%. On the other hand, Gorenflo's and lung et al.'s correlation showed only 5.8% and 6.4% deviations respectively in the entire nucleate boiling range.

활성슬러지 수용액 내 침지식 정밀여과용 중공사막의 산기량에 따른 임계 투과유속 (Critical Flux with Respect to Aeration Rate for the Submerged Microfiltration Hollow Fiber Membrane in the Activated Sludge Solution)

  • 정도인;정건용
    • 멤브레인
    • /
    • 제26권2호
    • /
    • pp.166-172
    • /
    • 2016
  • 본 연구에서는 산기량의 변화에 따른 임계 투과유속을 투과유속단법으로 측정하였다. 유효 막 면적이 $85cm^2$이고 공칭 세공크기가 $0.4{\mu}m$인 중공사형 막모듈을 MLSS 5,000 mg/L인 활성슬러지 수용액에 침지시켜 투과 실험하였다. 산기시키지 않을 경우 임계 투과유속은 $15.2L/m^2{\cdot}h$로 측정되었으나 산기량을 100에서 1,000 mL/min까지 증가시키면 임계 투과 유속이 20.6에서 $32.5L/m^2{\cdot}h$까지 크게 상승하였다.