• Title/Summary/Keyword: critical field

Search Result 2,318, Processing Time 0.026 seconds

Critical Current Density Distribution Analysis of HTS Tape (고온초전도 테이프의 임계전류밀도 분포 해석)

  • 강준선;나완수;권영길;손명환;김석환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.277-280
    • /
    • 2002
  • It is well known that the critical current of a HTS tape has anisotropic characteristic in magnetic field. We are interested in critical current density distribution of a HTS tape. We assumed the experimentally obtained Ic-B curves do represent the local properties of HTS tapes and calculated the critical current density distribution of HTS tapes using numerical method. Also we predicted the critical current of the tapes.

  • PDF

Critical Illness Myopathy (위험질병 근병증)

  • Lee, Dong Kuck
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.91-97
    • /
    • 2002
  • The field of critical care medicine has flourished, but an unfortunate result of improved patient survival in the intensive care unit is the occurrence of certain acquired neuromuscular disorders. During the last two decades, various neuromuscular disorders were recognized as common causes of weakness occurring in critically ill patients. The two most common disorders are an acute quadriplegic myopathy predominantly associated with the use of intravenous corticosteroids and neuromuscular junction blocking agents and severe systemic illness termed critical illness myopathy(CIM), and an axonal sensorimotor polyneuropathy termed critical illness polyneuropathy. I will review briefly about general components of the CIM.

  • PDF

Mathematical modeling of concrete pipes reinforced with CNTs conveying fluid for vibration and stability analyses

  • Nouri, Alireza Zamani
    • Computers and Concrete
    • /
    • v.19 no.3
    • /
    • pp.325-331
    • /
    • 2017
  • In this study, vibration and stability of concrete pipes reinforced with carbon nanotubes (CNTs) conveying fluid are presented. Due to the existence of CNTs, the structure is subjected to magnetic field. The radial fore induced with fluid is calculated using Navier-Stokes equations. Characteristics of the equivalent composite are determined using Mori-Tanaka model. The concrete pipe is simulated with classical cylindrical shell model. Employing energy method and Hamilton's principal, the motion equations are derived. Frequency and critical fluid velocity of structure are obtained analytically based on Navier method for simply supported boundary conditions at both ends of the pipe. The effects of fluid, volume percent of CNTs, magnetic field and geometrical parameters are shown on the frequency and critical fluid velocity of system. Results show that with increasing volume percent of CNTs, the frequency and critical fluid velocity of concrete pipe are increased.

The Influence of Calcining and Sintering Conditions on the Properties of $YBa_2Cu_3O_{7-x}$ Superconducting Ceramics Prepared by the Polymeric Precursor Process (Polymeric Precursor법으로 제조한 $YBa_2Cu_3O_{7-x}$초전도세라믹스의 특성에 대한 하소 및 소결조건의 영향)

  • 석상일;오재희
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.1
    • /
    • pp.37-45
    • /
    • 1991
  • The critical current density, electrical conductivity, critical magnetic field, Meissner effect, apparent density, and microstructure of YBa2Cu3O7-x ceramic superconductor prepared by polymeric precursor, while varing calcining and sintering conditions, were investigated. The best superconducting properties could be obtained from the body sintered at 93$0^{\circ}C$ for 10h after calcining at 90$0^{\circ}C$ for 10h, which gave 383A/$\textrm{cm}^2$ of critical current density(Jc), 96K of onset temperature(Tonset), 94. 8K of zero temperature (Tzero) 225 Oe of critical magnetic field (Hc1), 72.8% of superconducting volume fraction measured by Meissner effect and 6.28g/㎤ of apparent density.

  • PDF

A Study on Minimum Volume of Highly Homogeneous Superconducting Coil (균일자장 초전도코일의 체유최소화에 관한 연구)

  • 이승원;권영안
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.1
    • /
    • pp.38-43
    • /
    • 1985
  • Since the superconductor type II with high critical current and high critical magnetic field was discovered in 1961, there were many studies on the superconducting coil for high field and highly homogeneous field. The graphical method and the numerical method by Newton Raphson technique have been studied as the method for design of homogeneous superconducting coil. It is comparatively easy to get a compensating coil for any given main coil by the above methods, but it is too laborious to get a general solution for main coil dimension. This paper studies the optimal design method for minimum volume of superconducting coil under certain central field and highly homogeneous field. The present method makes use of the nonlinear programming for optimization. The optimal solution of NMR superconducting coils by this method are demonstrated very well.

  • PDF

$100 A/mm^2$ Class Bi-2223 Tapes in Electromechanical Devices (전력기기에서 $100 A/mm^2$급 Bi-2223테이프)

  • 류경우;최경주;성기철;류강식
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • $100 A/mm^2$ class Bi-2223 tapes have recently become commercially available. Some important characteristics of the tapes, e .g. critical current, ac loss, characteristics at joint, fault current characteristics, are required for an application such as a power cable or a power transformer. In this paper they have been investigated experimentally. The results indicate that the self-field loss of the high current density tapes is not negligible, compared to resistive loss in a copper wire for the same currents. In a cable, the self-field loss for relatively large currents is much larger than the magnetization loss due to an external field. But in a transformer, the magnetization loss is dominant, compared to the self-field loss. Finally the fault current characteristics show that the high current density tapes are never safe from burn-out even for fault currents with a few cycles.

Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube (전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구)

  • Ryu, S.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

Magnetic Properties of the $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$ $High-T_{C}$ Superconductor (고온 초전도체 $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$의 자기적 특성 연구)

  • 이성규;이주일;김문석;유성초;임우영;백종성
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • The magnetic properties of the $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$ superconductor were studied as a function of Sn concentration by utilizing both the vibrating sample magnetometer (VSM) and torque magnetometer. Unlike the cases where Fe and Co were substituted for Cu, the superconducting transition temperature was maintained above 90 K until x reached the value of 0.36. The lower critical field $H_{c1}(T)$ and upper critical field $H_{c2}(T)$ are measured as a function of temperature and external magnetic field, respectively. By aid of these results, $H_{c1}(0)$.($H_{c2}(0)$), the coherence length ${\varepsilon}_{0}$, the penetration depth ${\lambda}_{0}$, and the Ginzburg-Landau parameter k were oqtained. Flux pinning was also observed in the sample.

  • PDF

DC V-I Characteristics of a High Temperature Superconductor for a 600 kJ Superconducting Magnetic Energy Storage Device in an Oblique External Magnetic Field (경사 외부자장에 대한 600 kJ급 SMES용 HTS도체의 DC V-I 특성)

  • Li, Zhu-Yong;Ma, Yong-Hu;Ryu, Kyung-Woo;Choi, Se-Yong;Kim, Hae-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • We are developing a small-sized high temperature superconducting magnetic energy storage (HTS-SMES) magnet with the nominal storage capacity of 600 kJ, which provides electric power with high quality to sensitive electric loads. Critical current and N-value of a high temperature superconductor with large current, which was selected for the development of the 600 kJ HTS-SMES magnet, were investigated in various oblique external magnetic fields. Based on the critical current and N-value measured for the short sample conductor, we discussed the DC V - I characteristic of a model coil fabricated with the same conductor of 500 m. The results show that the measured critical current and N-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2 T. However, for oblique fields, its critical current and N -value abruptly decrease in all external magnetic fields. Moreover, the measured critical current of the model coil well agrees with the numerically calculated one based on the DC V - I characteristic measured for the short sample conductor. This suggest that losses and critical currents for an HTS-SMES magnet made up of a high temperature superconductor with anisotropic characteristic are predictable from the data of a short sample conductor.

Electromagnetic properties of HTS coated conductors fabricated by PLD and MOD (PLD 및 MOD법으로 제조된 2세대 HTS 선재의 전자기 특성)

  • Oh, Sang-Soo;Hwang, Sun-Yuk;Song, Kyu-Jeong;Kang, Suk-Il;Ha, Dong-Woo;Ko, Rock-Kil;Park, Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.65-68
    • /
    • 2004
  • A lot of R&D efforts are being concentrated on the development of high performance HTS coated conductors(CC). Unlike the HTS Bi-2223 tape, a variety of processes have been tried to fabricate CC tapes. PLD and MOD are believed to be very effective methods, and high critical currents of long length CC tape have been reported. In this study, we prepared two kinds of YBCO CCs to evaluate electromagnetic property. One is YBCO tape deposited on IBAD template by PLD and the other is AMSC's MOD CC tape Critical current (Ic) in magnetic fields, its angular dependency, and n-value were measured and analyzed. Magnetic field property of Ic was appeared to be different due the fabrication process. MOD tape showed higher in-field property, n-value of both PLD and MOD tapes exponentially decreased with magnetic field. MOD tape showed higher n-value in whole magnetic fields.

  • PDF