• 제목/요약/키워드: critical duration

검색결과 455건 처리시간 0.024초

스테인레스강 라미네이션된 DyBCO 초전도 선재의 퀜치 특성 (Quench characteristics of stainless steel laminated DyBCO coated conductor)

  • ;김태형;오상수;송규정;김호민;박권배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.1-4
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. Coated conductors can be stabilized with different metals and alloys for different types of application, to yield excellent electrical, thermal and mechanical performance. We have experimentally studied the dependence of quench and recovery characteristics of stainless steel stabilized coated conductors on the amplitude of current and duration time. Stability test of 3cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100ms, with amplitude up to ~6 times the critical current. The transport current that flows before and after the current pulse was fixed at about ~80-85% critical current. We analyzed the quench and recovery phenomena of the test sample using the current voltage characteristic.

소프트웨어 프로젝트 의사결정 지원을 위한 몬테카를로 시뮬레이션의 활용 (Applying Monte Carlo Simulation for Supporting Decision Makings in Software Projects)

  • 한혁수;김초이
    • 한국IT서비스학회지
    • /
    • 제9권4호
    • /
    • pp.123-133
    • /
    • 2010
  • There are many occasions on which the critical decisions should be made in software projects. Those decisions are basically related to estimating and predicting project parameters such as costs, efforts, and duration. The project managers are looking for methods to make better decisions. The decisions about project parameters are recommended to be performed based on historical data of Similar projects. The measures of the tasks in past projects may have different shapes of distributions. we need to add those measures to get a predicted project measures. To add measures with different shapes of distribution, we need to use Monte Carlo Simulation. In this paper, we suggest applying Monte Carlo Simulation for supporting decision makings in software project. We implemented best-fit case and scheduling estimations with Cristal Ball, a commercial product of Monte Carlo simulation and showed how the suggested approach supports those critical decision makings.

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF

중증 폐혈전색전증 환자에서 Urokinase와 Alteplase의 효과 및 출혈 합병증 비교 (The Therapeutic Efficacy and the Bleeding Complications of Urokinase and Alteplase in Patients with Massive Pulmonary Thromboembolism)

  • 유정완;김원영;최창민;홍상범;오연목;심태선;임채만;이상도;김우성;김동순;김원동;고윤석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제66권1호
    • /
    • pp.6-12
    • /
    • 2009
  • 연구배경: 폐혈전색전증 환자에서 혈전용해제의 효과는 차이가 없는 것으로 보고되어 있으나 출혈 등의 부작용에 대해서는 잘 알려져 있지 않다. 본 연구는 한 병원에서 중증 폐혈전색전증환자들에 사용한 alteplase와 urokinase의 치료효과 및 출혈 유발 정도를 비교하였다. 방법: 2000년 1월부터 2008년 7월까지 대상 환자 40명을 urokinase군(16명)과 alteplase군(24명)으로 나누어 의무기록을 후향적으로 분석하였다. 결과: 혈전용해제 사용한 이유는 혈역학적 불안정 23명, 중증 우심실부전 7명 그리고 헤파린 사용에도 불구하고 진행하는 저산소증 10명이었다. 두 군간 나이, APACHE II, SOFA score, 혈전용해제에서 유의한 차이는 없었다. 혈전용해제를 사용 후 승압제의 사용기간에서 aletplase군이 urokinase군보다 더 짧았으나, 인공호흡기 사용 기간과 중환자실 입원기간에서는 양 군간 유의한 차이가 없었다. 입원기간 동안 사망한 환자수는 13명(30%)으로 urokinase와 alteplase군 5명, 8명으로 유의한 차이는 없었고, 폐혈전색전증과 연관된 사망한 환자수에서도 urokinase와 alteplase군에서 1명, 4명으로 유의한 차이는 없었다. 혈전용해제 사용 후 수술적 치료가 필요한 환자 수도 urokinase군 2명, alteplase군 1명으로 차이가 없었다. 혈전용해제 사용 후 발생한 출혈은 14명(35%)에서 관찰되었고 urokinase군 3명(7.5%), alteplase군 11명(27.5%)으로 urokinase군에서 적은 경향을 보였다. 중증 출혈은 2명으로 모두 alteplase군에서 발생하였으며 1명은 뇌출혈로 사망하였다. 결론: 중증 폐색전혈전증환자에서 urokinase 사용은 alteplase에 비하여 치료효과는 차이가 없으면서 출혈의 위험은 낮을 것으로 사료된다.

내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구 (The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU)

  • 정영주;고윤석;임채만;이재승;유미현;오연목;심태선;이상도;김우성;김동순;김원동;홍상범
    • Tuberculosis and Respiratory Diseases
    • /
    • 제59권4호
    • /
    • pp.389-396
    • /
    • 2005
  • 목 적 : 중환자실 환자에서 중심정맥관 관련 감염증은 원내 감염의 주요 부분을 차지한다. 이러한 중심 정맥관 관련 감염증을 감소시키기 위하여 chlorhexidine-silver sulfadiazine coated catheter (CHSS) 사용에 대한 임상적 유용성에 대해서는 논란의 여지가 있지만, 국내에서는 아직 이와 관련된 보고가 없었다. 본 연구는 non-coated catheter (NCC)와 CHSS의 중심 정맥관 관련 감염증의 차이를 비교하고자 하였다. 대상 및 방법 : 2004년 1월부터 12월까지 12개월간 서울아산병원 내과계 중환자실에 입원하여 48시간 이상 중심정맥관을 삽입하였던 446 예을 대상으로 하였다. NCC(n=187)과 CHSS (n=259)에서 중심정맥관과 환자의 특성, 중심정맥관 삽입 위치, 평균 삽입 일수, 집락화중심정맥관 관련 감염증의 빈도, 및 원인균 등에 대하여 후향적인 방법으로 조사하였다. 결 과 : 1) NCC와 CHSS에서 환자군의 나이 ($62{\pm}16$, $63{\pm}15$; p=0.42) 세, 성비 (94:50, 141:69; p=0.9), 중환자실 재원일수 ($29{\pm}37$, $26{\pm}44$ ;p=0.42) 일, 인공 호흡기 사용 기간 ($17{\pm}22$, $15{\pm}19$; p=0.17) 일, 카테터 삽입 시 APACHE III 점수는 ($81{\pm}34$, $82{\pm}37$; p=0.61) 차이가 없었다. 2) 평균 카테터 삽입 기간은 NCC $11{\pm}8$ 일, CHSS $11{\pm}9$ 일 이었고(p=0.98), 총 카테터 일수는 NCC 2176일, CHSS 3035 일 이었다. NCC와 CHSS에서 카테터 감염 발생 환자는 각각 9명 (4.8%), 4명(1.5%) 으며, 1000 catheter-day당 감염 건수는 4.1건, 1.3건 이었다(p=0.04). 삽입 위치에서는 내경 정맥 삽입 시 CHSS에서 NCC 보다 중심정맥관 관련 감염증이 감소하였다 (p=0.01). 3) 중심정맥관 관련 감염증에서 동정된 균은 NCC에서 Stazfphylococcus aureus 3명, Candida species 3명, coagulase-negative Staphylococci 2명, Klebsiella 1명, 이었고 CHSS는 coagulase-negative Staphylococci 2명, Candida species 2명, Proteus 1명 이었다. 결 론 : 내과계 중환자실 환자에서 중심정맥관 삽입 시 NCC에 비해 CHSS에서 중심정맥관 감염율이 감소하였으며, 특히 삽입 위치가 내경 정맥일 때 유의한 감소를 보였다.

콘크리트 강도의 진동영향에 관한 연구 (A Study on the Strength of Concrete Affected by Revibration)

  • 정하선;권영웅;오용복
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.37-40
    • /
    • 1991
  • This experimental study was performed to find out the vibration damage of concrete. The major factors of this test were duration of vibration and curing age of concrete when vibrated. According to the serial test results, construction vibrations may cause critical damage to the concrete structures if the age of concrete when vibrated is about 4 hours.

  • PDF

소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구 (A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control)

  • 안태진;박종윤;류희정;김중훈
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.385-398
    • /
    • 2003
  • 내배수시설계획시 최대저류비에 의한 유수지 규모의 결정 방법은 이전 연구자에 의하여 제시된 바 있다. 본 연구에서는 동두천시 11개 소규모 내배수시설을 선정하여 분석한 결과, 배수면적이 작고 펌프기능이 강화된 내배수 시설에서는 강우지속기간별 우수지의 저류비의 차이는 미미하므로 최대저류비에 의한 조정지 규모의 결정은 무리가 있음을 알 수 있었다. 또한 최대저류비에 의하여 결정된 조정지 용량을 펌프에 의하여 배제되는 시간은 펌프의 허용시동간격보다 짧은 경우도 있어 펌프의 빈번한 작동을 초래한다. 그러므로 조정지는 펌프의 빈번한 작동에 의한 펌프 고장의 가능성을 피할 수 있는 규모로 결정되어야 한다. 다양한 펌프용량을 적용하여 분석한 결과, 소유역에서도 조정지의 기능이 강화된 내수배제시설에서는 최대저류비를 기준으로 한 조정지 용량의 결정은 펌프운영 측면에서 타당함을 알 수 있었다. 따라서 본 연구에서는 소규모 배수구역에서 조정지용량의 결정시 펌프의 계획배수량과 유수지의 용량에 따른 펌프의 시동빈도를 반영하여 기존의 최대저류비에 의한 방법을 개선한 방안을 제시하였다. 또한 유수지 규모와 펌프용량의 관계를 간단한 선형계획모형으로 분석한 결과, 종래의 유수지 홍수추적에 의한 유수지 용량 결정은 도시지역의 내배수시설 계획에만 타당함을 알 수 있었다.

Risk Factors for Predicting Hypoxia in Adult Patients Undergoing Bronchoscopy under Sedation

  • Choi, Ji Soo;Lee, Eun Hye;Lee, Sang Hoon;Leem, Ah Young;Chung, Kyung Soo;Kim, Song Yee;Jung, Ji Ye;Kang, Young Ae;Park, Moo Suk;Chang, Joon;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권4호
    • /
    • pp.276-282
    • /
    • 2020
  • Background: Flexible bronchoscopy is one of the essential procedures for the diagnosis and treatment of pulmonary diseases. The purpose of this study was to identify the risk factors associated with the occurrence of hypoxia in adults undergoing flexible bronchoscopy under sedation. Methods: We retrospectively analyzed 2,520 patients who underwent flexible bronchoscopy under sedation at our tertiary care university hospital in South Korea January 1, 2013-December 31, 2014. Hypoxia was defined as more than 5%-point reduction in the baseline percutaneous oxygen saturation (SpO2) or SpO2 <90% for >1 minute during the procedure. Results: The mean age was 64.7±13.5, and 565 patients developed hypoxia during the procedure. The mean sedation duration and midazolam dose for sedation were 31.1 minutes and 3.9 mg, respectively. The bivariate analysis showed that older age, a low forced expiratory volume in one second (FEV1), use of endobronchial ultrasound, the duration of sedation, and the midazolam dose were associated with the occurrence of hypoxia during the procedure, while the multivariate analysis found that age >60 (odds ratio [OR], 1.32), a low FEV1 (OR, 0.99), and a longer duration of sedation (>40 minutes; OR, 1.33) were significant risk factors. Conclusion: The findings suggest that patients older than age 60 and those with a low FEV1 tend to develop hypoxia during the bronchoscopy under sedation. Also, longer duration of sedation (>40 minutes) was a significant risk factor for hypoxia.

혈당 조절 프로토콜 적용에 따른 흉부외과 중환자의 혈당 조절 상태와 혈당 변동 (The Effects of the Application of a Glucose Control Protocol on Glycemia and Glucose Variability in Critically Ill Cardiothoracic Surgery Patients)

  • 유혜진;이남주;이순행
    • 중환자간호학회지
    • /
    • 제8권2호
    • /
    • pp.1-12
    • /
    • 2015
  • Purpose: The study sought to determine the state of blood glucose control, and the consequent clinical effects and variation in blood glucose level, of adult patients admitted to intensive care units following cardiothoracic surgery by comparing the blood glucose levels before and after the application of a blood glucose control protocol. Methods: The protocol was developed by modifying and supplementing the Yale protocol, and was first used in 2012. The resulting blood glucose data of an experimental group (n = 314), to which the blood glucose control protocol had been applied, and a control group (n = 347), whose blood glucose levels had been controlled according to physicians'prescriptions without the protocol, were collected through the medical records. Results: The target blood glucose ratio increased significantly in the experimental group, and the low blood glucose ratio decreased significantly in the experimental group. The two groups exhibited a significant difference (p < .001) in the degree of variation in the blood glucose levels. The duration of the use of a ventilator was significantly reduced in the experimental group (p < .001). Conclusion: It is expected that the protocol can be used for the safe and effective control of critically ill cardiothoracic surgery patients' blood glucose levels.

Bi-2223 초전도 선재의 열처리에 따른 초전도 특성 및 상분석 (The effect of heat treatment condition on superconducting property and phase analysis of Bi-2223 tapes)

  • 최정규;하홍수;이동훈;양주생;황선역;하동우;오상수;권영길;이세종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.73-76
    • /
    • 2003
  • Phase transformation of Bi-2223 tape during the final heat treatment has been investigated through the various duration time of heat treatment in a specially designed 3-step heat treatment. It was found that the phase assemblage in the sintering was determined by the sintering time and temperature. In this study, sintering time was changed to optimize the Bi-2223 phase assemblage, and acquire high critical current density. High critical current samples with Ic = 85 A and Je = 8.9 kA/$cm^2$ have been measured at 77K and self-field for 55-filament tapes sintered by optimum condition.

  • PDF