• 제목/요약/키워드: critical currents

검색결과 160건 처리시간 0.022초

Correlation between mEPSC Amplitude and Rise Time upon the Blockade of AMPA Receptor Desensitization at Hippocampal Synapses

  • Jung, Su-Hyun;Choi, Suk-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권2호
    • /
    • pp.81-85
    • /
    • 2002
  • Conventional views of synaptic transmission generally overlook the possibility of 'postfusional-control' the regulation of the speed or completeness of transmitter release upon vesicular fusion. However, such regulation often occurs in non-neuronal cells where the dynamics of fusion-pore opening is critical for the speed of transmitter release. In case of synapses, the slower the transmitter release, the smaller the size and rate-of-rise of postsynaptic responses would be expected if postsynaptic neurotransmitter receptors were not saturated. This prediction was tested at hippocampal synapses where postsynaptic AMPA-type glutamate receptors (AMPAR) were not generally saturated. Here, we found that the small miniature excitatory postsynaptic currents (mEPSCs) showed significantly slower rise times than the large mEPSCs when the sucrose-induced mEPSCs recorded in cyclothiazide (CTZ), a blocker for AMPAR desensitization, were sorted by size. The slow rise time of the small mEPSCs might result from slow release through a non-expanding fusion pore, consistent with postfusional control of neurotransmitter release at central synapses.

$\textrm{I}_{DDQ}$ 테스팅을 위한 빠른 재장형 전류감지기 (Fast built-in current sensor for $\textrm{I}_{DDQ}$ testing)

  • 임창용;김동욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.811-814
    • /
    • 1998
  • REcent research about current testing($\textrm{I}_{DDQ}$ testing) has been emphasizing that $\textrm{I}_{DDQ}$ testing in addition to the logical voltage testing is necessary to increase the fault coverage. The $\textrm{I}_{DDQ}$. testing can detect physical faults other than the classical stuck-at type fault, which affect reliability. One of the most critical issues in the $\textrm{I}_{DDQ}$ testing is to insert a built-in current sensor (BICS) that can detect abnormal static currents from the power supply or to the ground. This paper presents a new BICS for internal current testing for large CMOS logic circuits. The proposed BICS uses a single phase clock to minimize the hardware overhead. It detects faulty current flowing and converts it into a corresponding logic voltage level to make converts it into a corresponding logic voltage level to make it possible to use the conventional voltage testing techniqeus. By using current mirroring technique, the proposed BICS can work at very high speed. Because the proposed BICS almost does not affects normal operation of CUT(circuit under test), it can be used to a very large circuit without circuit partitioning. By altenating the operational modes, a circuit can be $\textrm{I}_{DDQ}$-tested as a kind of self-testing fashion by using the proposed BICS.

  • PDF

Design and fabrication of race-track type field coil for the high temperature superconduction generator

  • Baik, S.K.;Jo, Y.S.;Ha, H.S.;Lee, E.Y.;Jeong, D.Y.;Kwon, Y.K.;Ryu, K.S.;Sohn, M.H.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.248-251
    • /
    • 2000
  • The fabrication and characteristics of HTS race-track type field coil for generators was carried out. Field coils are composed of 3 pancake coils wound by 37-filamental Bi-2223/Ag-alloy tapes. The winding machine is horizontal type. The critical currents (I$_c$) of the superconducting tapes were measured with variation of bending strain and external magnetic fields. I$_c$ of both whole field coils and 3 pancake coils were measured as a function of temperature. At 77K under the self-field, I$_c$ of whole field coils was 12A, while in the case of middle pancake coil, I$_c$ was 15A. The distribution of magnetic field B was obtained, using 3-D FEM. Our simulation showed that maximums of B${\bot}$A in x-y plane were locally distributed in both the upper and the lower coils. In addition, the fabrication processes and the characteristics of field coil are described.

  • PDF

Calculation of Joule heating and temperature distribution generated in the KSTAR superconducting magnet structure

  • Seungyon Cho;Park, Chang-Ho;Sa, Jeong-Woo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.78-83
    • /
    • 2002
  • Since the KSTAR superconducting magnet structure should be maintained at a cryogenic temperature of about 4 K, even a small amount of heat might be a major cause of the temperature rise of the structure. The Joule heating by eddy currents induced in the magnet structure during the KSTAR operation was found to be a critical parameter for designing the cooling scheme of the magnet structure as well as defining the requirements of the refrigerator for the cryogenic system. Based on the Joule heating calculation, it was revealed that the bulk temperature rise of the magnet coil structure was less than 1 K. The local maximum temperature especially at the inboard leg of the TF coil structure increased as high as about 21 K for the plasma vertical disruption scenario. For the CS coil structure, the maximum temperature was obtained from the PF fast discharging scenario. This means that the vertical disruption and PF fast discharging scenarios are the major scenarios for the design of TF and CS coil structures, respectively. For the reference scenario, the location of maximum temperature spot changes according to the transient current variation of each PF coil.

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

Scanning Hall probe를 이용한 coated conductor의 field profile 측정과 current profile 계산 (Measurements of the field profiles using scanning Hall probe and calculation of the current profiles of coated conductors)

  • 유재은;이상무;정예현;이재영;정용환;염도준;김호섭;하홍수;오상수
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.169-174
    • /
    • 2007
  • We measured the field profiles, H(x)'s of coated conductors by using scanning Hall probe method when various magnetic fields, $H{_\alpha}'s$ or currents, I's were applied. From the measured field profiles, we calculated the current profiles, J(x)'s by the inversion method. The calculated J(x)'s of coated conductors show some different properties from the standard critical state model. $J{_c}'s$ are inhomogeneous varying with the positions and are not constant when $H_{\alpha}$ or I changes. And when I decreases the features of current reversion are remarkably different from the model.

  • PDF

Preparation and Characterization of Doped $Fe_2O_3$ and GaAs Photosemiconductive Electrodes for $CO_2$ Fixation

  • Kim, Il Kwang;Lee, Seong Jae;Kim, Min Su;Jeong, Seung Il;Park, Byung Sun;Kim, Youn Geun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.669-674
    • /
    • 1995
  • The preparation and characterization of photosemiconductive electrodes of GaAs and of $Fe_2O_3$ doped with MgO or CaO were investigated. The doped $Fe_2O_3$ photosemiconductive electrodes were prepared from thin films sintered at temperatures from 1,100 to $1,450^{\circ}C$, and rapidly quenched in distilled water. The surfaces of the electrodes containing both corundum structure of $Fe_2O_3$ and spinel structure of $Mg_xFe_{3-x}O_4$ or $Ca_xFe_{3-x}O_4$ were analyzed by X-ray diffraction and scanning electron microscopy. The cathodic and anodic photocurrents on these electrodes indicated a critical doping amount of 5-11 wt. %. The photocurrents were enhanced when GaAs electrodes were treated with methylene violet the anodic photo-currents were temporarial enhanced and changed to the cathodic ptotocurrents after the surface was dryed.

  • PDF

동일 병렬 저항을 이용한 초전도 저항형 한류소자 직렬연결방안 및 전압용량 증대 (Increase of the Voltage Rating of Resistive Type Superconducting Fault Current Limiter Using Equal Shunt Resistors)

  • 차상도;김혜림;심정욱;한용희;현옥배
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.327-334
    • /
    • 2003
  • We have investigated the quench behavior of the series connection of resistive type superconducting fault current limiter (SFCL) components based on YBCO films. Equal shunt resistors $R_s$ across individual SFCL components successfully produced simultaneous Quenches for 5 components in series, resulting in equal application of voltage to all components. If the two components having the highest and the lowest critical currents ($I_c$) quench safely, others quench altogether The highest shunt resistance is to guarantee the safe quenches of all components, leading to the equal voltage applications within the first half cycle after a fault in the short circuit test. The highest $R_s$ was found to be 28 [$\Omega$] for the components in the given quench environment. Considering the safe quenches and protection coordination, the optimal $R_s$ was suggested to be approximately a half of the highest $R_s$,, allowing wide selection of $R_s$ and $I_c$'s. This design provides a practical wav of connecting small SFCL components in series for high voltage application.

SMES용 초전도코일 제작 및 특성 (Fabrication and Test of a Superconducting Coil for SMES)

  • 김해종;성기철;조전욱;배준한;김석환;심기덕;이언용;권영길;류경우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권11호
    • /
    • pp.557-562
    • /
    • 2003
  • To develop a stable and compact small-sized superconducting magnetic energy storage (SMES) system, which provides electric power with high quality to sensitive electric loads, we fabricated a SMES coil and tested it. Because such a large-sized superconducting coil quenches far away from its critical current, the recovery current is frequently used as a stability criterion in the coil fabrication. Therefore, we first investigated the recovery current characteristics of the large current conductor, which was used in our SMES coil fabrication. The test results indicate that the recovery currents measured in the conductor are nearly identical to those based on the single wire. This implies that the recovery current is affected by the conductor's cooling condition rather than its size and current capacity. In the SMES coil test the first quench occurred at 1250 A, which is equivalent to the stored energy of about 2 MJ. It corresponds to the quench current density of about $130A/mm^2$ This value is much higher in comparison with that reported in the other work. In addition, the first quench current of the coil agrees well with the measured recovery current of the conductor having similar cooling condition with it. This means that to determine the recovery current of a conductor is, first of all, important in the design and fabrication of a large-sized superconducting coil.

Improvement of the Spin Transfer Induced Switching Effect by Copper and Ruthenium Buffer Layer

  • Nguyen T. Hoang Yen;Yi, Hyun-Jung;Joo, Sung-Jung;Jung, Myung-Hwa;Shin, Kyung-Ho
    • Journal of Magnetics
    • /
    • 제10권2호
    • /
    • pp.48-51
    • /
    • 2005
  • The spin transfer induced magnetization switching has been reported to occur in magnetic multilayer structures whose scope usually consists of one stack of ferromagnetic / non-ferromagnetic / ferromagnetic (F / N / F) materials. In this work, it is shown that: 1) Copper used as a buffer layer between the free Co and the Au cap-layer can clearly increase the probability to get the spin transfer induced magnetization switching in a simple spin valve Co 11 / Cu 6/ Co 2 (nm); 2) Furthermore, when Ruthenium is simultaneously applied as a buffer layer on the Si-substrate, the critical switching currents can be reduced by $30\%$, and the absolute resistance change delta R $[{\Delta}R]$ of that stack can be enlarged by $35\%$. The enhancement of the spin transfer induced magnetization switching can be ascribed to a lower local stress in the thin Co layer caused by a better lattice match between Co and Cu and the smoothening effect of Ru on the thick Co layer.