• 제목/요약/키워드: critical current ratio

검색결과 174건 처리시간 0.023초

정지여자형 동기발전기의 계자이상전압 억제에 관한 연구 (A Study on the Suppression of Abnormal Field Voltage in the Static Excitor Type Synchronous Generator)

  • 윤병도;이원교
    • 대한전기학회논문지
    • /
    • 제35권2호
    • /
    • pp.55-61
    • /
    • 1986
  • This paper describes the generation region and suppression effect of the abnormal field voltage induced when the synchronous generator is switched to the infinite bus, the critical value of negative field current is calculated by simmulation which has parameters of the phase difference and voltatge ratio between the bus and the generator. The suppression effect of discharge resistance connected in parallel with the field circuit is also investigated. According to this study, the optimal value of discharge resistance which can suppress effectively the abnormal field voltage may be calculated.

  • PDF

Extended Use of Extracorporeal Membrane Oxygenation for Acute Respiratory Distress Syndrome: A Retrospective Multicenter Study

  • Kim, Won-Young;Park, SeungYong;Kim, Hwa Jung;Baek, Moon Seong;Chung, Chi Ryang;Park, So Hee;Kang, Byung Ju;Oh, Jin Young;Cho, Woo Hyun;Sim, Yun Su;Cho, Young-Jae;Park, Sunghoon;Kim, Jung-Hyun;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • 제82권3호
    • /
    • pp.251-260
    • /
    • 2019
  • Background: Beyond its current function as a rescue therapy in acute respiratory distress syndrome (ARDS), extracorporeal membrane oxygenation (ECMO) may be applied in ARDS patients with less severe hypoxemia to facilitate lung protective ventilation. The purpose of this study was to evaluate the efficacy of extended ECMO use in ARDS patients. Methods: This study reviewed 223 adult patients who had been admitted to the intensive care units of 11 hospitals in Korea and subsequently treated using ECMO. Among them, the 62 who required ECMO for ARDS were analyzed. The patients were divided into two groups according to pre-ECMO arterial blood gas: an extended group (n=14) and a conventional group (n=48). Results: Baseline characteristics were not different between the groups. The median arterial carbon dioxide tension/fraction of inspired oxygen ($FiO_2$) ratio was higher (97 vs. 61, p<0.001) while the median $FiO_2$ was lower (0.8 vs. 1.0, p<0.001) in the extended compared to the conventional group. The 60-day mortality was 21% in the extended group and 54% in the conventional group (p=0.03). Multivariate analysis indicated that the extended use of ECMO was independently associated with reduced 60-day mortality (odds ratio, 0.10; 95% confidence interval, 0.02-0.64; p=0.02). Lower median peak inspiratory pressure and median dynamic driving pressure were observed in the extended group 24 hours after ECMO support. Conclusion: Extended indications of ECMO implementation coupled with protective ventilator settings may improve the clinical outcome of patients with ARDS.

Research on the Technology of Alternative Continuous Wide Spectral Spatial Heterodyne Spectrometer

  • Zhang, Wenli;Tian, Fengchun;Zhao, Zhenzhen;Song, An;Zhang, Li
    • Current Optics and Photonics
    • /
    • 제1권4호
    • /
    • pp.295-307
    • /
    • 2017
  • An innovative system for the alternative continuous wide spectral spatial heterodyne spectrometer (ACWS-SHS) is proposed. The relationship between the ACWS-SHS and the wide spectral spatial heterodyne spectrometer (WS-SHS) at the resolution limit, the spectral range, the grating diffraction efficiency and the interference fringes contrast ratio has been analyzed theoretically. Through the comparison of the theoretical analysis and simulation results, it is found that the two systems for the WS-SHS and the ACWS-SHS have the same resolution limit and spectral range, which are ${\delta}{\sigma}$ and ${\sigma}_{01}$, while in the ACWS-SHS system the critical diffraction efficiency of echelle grating is 68.39% and the critical contrast ratio of interference fringes is 0.4135, which is much better than the performance of the WS-SHS system. Therefore, the ACWS-SHS reduces the high requirements for the precision of equipment and expands the application field of SHS effectively.

Fabrication and characterization of $YBa_2Cu_3O_7$ step-edge Josephson junctions prepared on sapphire substrates

  • Lim, Hae-Ryong;Kim, In-Seon;Kim, Dong-Ho;Park, Yong-Ki;Park, Jong-Chul
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.146-150
    • /
    • 2000
  • Step edge Josephson junctions in c-axis oriented $YBa_2Cu_3O_7$ films were fabricated on $CeO_2$ buffered sapphire substrates. The step angle was controlled in the wide range of $20^{\circ}\sim75^{\circ}$ by the Ar ion milling technique. I-V curves of junction fabricated on the thickness ratio of $\sim$0.8 and the step angle of $35^{\circ}$ were exhibited RSJ-like behavior with $I_CR_N$ product of $\sim250{\mu}A$ and critical current density of $\sim2\times10^4A/cm^2$ at 77 K. Critical current of step edge junction was increased linearly with decreasing temperature but the normal resistance was almost constant. Total samples of step edge Josephson junction was satisfied a scaling behavior of $I_CR_N{\propto}(J_C)^{0.5}$.

  • PDF

P-${\Delta}$ Effects on the Reliability of Offshore Platforms

  • Leon, David-De;Dante Campos
    • Computational Structural Engineering : An International Journal
    • /
    • 제3권1호
    • /
    • pp.31-37
    • /
    • 2003
  • A typical marine platform in the Bay of Campeche is studied from the standpoint of structural reliability, and several characteristics of its deck such as slenderness and diameter/thickness ratios of the legs and actual degree of correlation between some variables are taken into account. The global and local buckling capacities of the deck legs are compared and the correlation coefficient between the critical axial load and the critical moment is assessed in order to validate its influence on the structural reliability. In addition, the influence of the vertical load, and its uncertainty, on the variance of the decks capacity, and latter on, on the platform's failure probability is assessed. The results presented may be used in future studies to further extend and upgrade the first version of the Reference Norm (PEMEX, 2000) and, in the longer term, to improve the current practice in the Design and Requalification of Offshore Marine Platforms in the Bay of Campeche.

  • PDF

Determinants of Nicotine Dependence in Chronic Obstructive Pulmonary Disease

  • Sim, Yun Su;Lee, Jin Hwa;Kim, Ki Uk;Ra, Seung Won;Park, Hye Yun;Lee, Chang-Hoon;Kim, Deog Kyeom;Shin, Kyeong-Cheol;Lee, Sang Haak;Hwang, Hun Gyu;Ahn, Joong Hyun;Park, Yong Bum;Kim, Yu-Il;Yoo, Kwang Ha;Jeong, Ina;Oh, Yeon-Mok;Lee, Sang-Do;KOLD Investigators
    • Tuberculosis and Respiratory Diseases
    • /
    • 제80권3호
    • /
    • pp.277-283
    • /
    • 2017
  • Background: Smoking cessation is the most powerful intervention to modify progress of chronic obstructive pulmonary disease (COPD), and nicotine dependence is one of the most important determinants of success or failure in smoking cessation. We evaluated nicotine dependence status and investigated factors associated with moderate to high nicotine dependence in patients with COPD. Methods: We included 53 current smokers with COPD in the Korean Obstructive Lung Disease II cohort enrolled between January 2014 and March 2016. Nicotine dependence was measured by using Fagerstrom test for nicotine dependence (FTND). Cognitive function was assessed by Korean version of Montreal Cognitive Assessment. Results: The median FTND score was 3, and 32 patients (60%) had moderate to high nicotine dependence. The median smoking amount was 44 pack-years, which was not related to nicotine dependence. Multiple logistic regression analysis revealed that high education status (odds ratio, 1.286; 95% confidence interval, 1.036-1.596; p=0.023), age <70 (odds ratio, 6.407; 95% confidence interval, 1.376-29.830; p=0.018), and mild to moderate airflow obstruction (odds ratio, 6.969; 95% confidence interval, 1.388-34.998; p=0.018) were related to moderate to high nicotine dependence. Conclusion: Nicotine dependence does not correlate with smoking amount, but with education level, age, and severity of airflow obstruction. Physicians should provide different strategies of smoking cessation intervention for current smokers with COPD according to their education levels, age, and severity of airflow obstruction.

2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성 (Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings)

  • 황종선;조용선;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

$\mu$SMES마그네트용 초전도도체의 안정성 및 퀀치 특성 (Stability and Quench Charcteristics of the SC Conductor for a $\mu$SMES Magnet)

  • 김해종;성기철;조전욱;권영길;류강식;최병주;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.19-23
    • /
    • 2000
  • We are developing a small-sized superconducting magnetic energy storge ($\mu$SMES) magnet with the storage capacity of a few megajoules, which provides electric power with high quality to sensitive electric loads. A kA class superconductor with a high coppe $r^erconductor ratio was selected as a candidate conductor. The superconductor was tested in two points of view, which are basic and important in development of the $\mu$SMES magnet. First, stabilities of the superconductor against localized disturbances such as wire motions were estimated by using a wire heater. Second, the quench current characteristics for different charge rates were also tested. The stability data showed that the short heat pulses made the conductor more unstable. The superconductor had relatively high recovery currents ranging between 40% and 50% of its critical currents. The quench tests indicated that the quench currents of the conductor were independent of current ramp rates up to 3000 A/s and nearly equal to its cuitical current data.ta.

  • PDF

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.