• 제목/요약/키워드: craniofacial cleft

검색결과 845건 처리시간 0.02초

Comparison of pain relief in soft tissue tumor excision: anesthetic injection using an automatic digital injector versus conventional injection

  • Hye Gwang Mun;Bo Min Moon;Yu Jin Kim
    • 대한두개안면성형외과학회지
    • /
    • 제25권1호
    • /
    • pp.17-21
    • /
    • 2024
  • Background: The pain caused by local anesthetic injection can lead to patient anxiety prior to surgery, potentially necessitating sedation or general anesthesia during the excision procedure. In this study, we aim to compare the pain relief efficacy and safety of using a digital automatic anesthetic injector for local anesthesia. Methods: Thirty-three patients undergoing excision of a benign soft tissue tumor under local anesthesia were prospectively enrolled from September 2021 to February 2022. A single-blind, randomized controlled study was conducted. Patients were divided into two groups by randomization: the experimental group with digital automatic anesthetic injector method (I-JECT group) and the control group with conventional injection method. Before surgery, the Amsterdam preoperative anxiety information scale was used to measure the patients' anxiety. After local anesthetic was administered, the Numeric Pain Rating Scale was used to measure the pain. The amount of anesthetic used was divided by the surface area of the lesion was recorded. Results: Seventeen were assigned to the conventional group and 16 to the I-JECT group. The mean Numeric Pain Rating Scale was 1.75 in the I-JECT group and 3.82 in conventional group. The injection pain was lower in the I-JECT group (p< 0.01). The mean Amsterdam preoperative anxiety information scale was 11.00 in the I-JECT group and 9.65 in conventional group. Patient's anxiety did not correlate to injection pain regardless of the method of injection (p= 0.47). The amount of local anesthetic used per 1 cm2 of tumor surface area was 0.74 mL/cm2 in the I-JECT group and 2.31 mL/cm2 in the conventional group. The normalization amount of local anesthetic was less in the I-JECT group (p< 0.01). There was no difference in the incidence of complications. Conclusion: The use of a digital automatic anesthetic injector has shown to reduce pain and the amount of local anesthetics without complication.

Orbital floor defect caused by invasive aspergillosis: a case report and literature review

  • Sang Woo Han;Min Woo Park;Sug Won Kim;Minseob Eom;Dong Hwan Kwon;Eun Jung Lee;Jiye Kim
    • 대한두개안면성형외과학회지
    • /
    • 제25권1호
    • /
    • pp.27-30
    • /
    • 2024
  • Fungal sinusitis is relatively rare, but it has become more common in recent years. When fungal sinusitis invades the orbit, it can cause proptosis, chemosis, ophthalmoplegia, retroorbital pain, and vision impairment. We present a case of an extensive orbital floor defect due to invasive fungal sinusitis. A 62-year-old man with hypertension and a history of lung adenocarcinoma, presented with right-side facial pain and swelling. On admission, the serum glucose level was 347 mg/dL, and hemoglobin A1c was 11.4%. A computed tomography scan and a Waters' view X-ray showed right maxillary sinusitis with an orbital floor defect. On hospital day 3, functional endoscopic sinus surgery was performed by the otorhinolaryngology team, and an aspergilloma in necrotic inflammatory exudate obtained during exploration. On hospital day 7, orbital floor reconstruction with a Medpor Titan surgical implant was done. In principle, the management of invasive sino-orbital fungal infection often begins with surgical debridement and local irrigation with an antifungal agent. Exceptionally, in this case, debridement and immediate orbital floor reconstruction were performed to prevent enophthalmos caused by the extensive orbital floor defect. The patient underwent orbital floor reconstruction and received intravenous and oral voriconazole. Despite orbital invasion, there were no ophthalmic symptoms or sequelae.

Auricle reconstruction with autologous costal cartilage versus polyethylene implants in microtia patients: a meta-analysis

  • Yun Jung Kim;Kyunghyun Min;Kyunghyun Min;Tai Suk Roh;Hyun-Soo Zhang;In Sik Yun
    • 대한두개안면성형외과학회지
    • /
    • 제25권4호
    • /
    • pp.179-186
    • /
    • 2024
  • Background: Auricle reconstruction is among the most challenging procedures in plastic and reconstructive surgery, and the choice of framework material is a critical decision for both surgeons and patients. This meta-analysis compared the outcomes of autologous auricle reconstruction using costal cartilage with those of alloplastic reconstruction using porous polyethylene implants. Methods: A literature review was conducted using the PubMed and Embase databases to retrieve articles published between January 2000 and June 2024. The outcomes analyzed included postoperative complications such as framework exposure, infection, skin necrosis, hematoma, and hypertrophic scars, as well as patient satisfaction. The proportions of reconstructive outcomes from each selected study were statistically analyzed using the "metaprop" function in R software. Results: Fourteen articles met our inclusion criteria. The group undergoing polyethylene implant reconstruction exhibited higher rates of framework exposure, infection, and skin necrosis, whereas the autologous reconstruction group experienced higher rates of hematoma and hypertrophic scars. Of all the complications, framework exposure was the only one to show a statistically significant difference between the two groups (p< 0.0001). In terms of patient satisfaction, those who underwent autologous cartilage reconstruction reported a higher rate of satisfaction, although this difference did not reach statistical significance in the meta-analysis (p= 0.076). Conclusion: There is no statistically significant difference in postoperative complications such as infection, hematoma, skin necrosis, and hypertrophic scars between auricle reconstructions using autologous costal cartilage and those using polyethylene implants. However, reconstructions with polyethylene implants show a significantly higher rate of framework exposure.

Three-dimensional computer navigation in the reconstruction of complex unilateral orbital fractures: evaluation and review of applications

  • Parampreet Singh Saini;Rajesh Kumar;Manu Saini;Tarush Gupta;Sunil Gaba;Ramesh Kumar Sharma
    • 대한두개안면성형외과학회지
    • /
    • 제25권4호
    • /
    • pp.161-170
    • /
    • 2024
  • Background: The eyes are the central aesthetic unit of the face. Maxillofacial trauma can alter facial proportions and affect visual function with varying degrees of severity. Conventional approaches to reconstruction have numerous limitations, making the process challenging. The primary objective of this study was to evaluate the application of three-dimensional (3D) navigation in complex unilateral orbital reconstruction. Methods: A prospective cohort study was conducted over 19 months (January 2020 to July 2021), with consecutive enrollment of 12 patients who met the inclusion criteria. Each patient was followed for a minimum period of 6 months. The principal investigator carried out a comparative analysis of several factors, including fracture morphology, orbital volume, globe projection, diplopia, facial morphic changes, lid retraction, and infraorbital nerve hypoesthesia. Results: Nine patients had impure orbital fractures, while the remainder had pure fractures. The median orbital volume on the normal side (30.12 cm3; interquartile range [IQR], 28.45-30.64) was comparable to that of the reconstructed orbit (29.67 cm3; IQR, 27.92-31.52). Diplopia improved significantly (T(10)= 2.667, p= 0.02), although there was no statistically significant improvement in globe projection. Gross symmetry of facial landmarks was achieved, with comparable facial width-to-height ratio and palpebral fissure lengths. Two patients reported infraorbital hypoesthesia at presentation, which persisted at the 6-month follow-up. Additionally, five patients developed lower lid retraction (1-2 mm), and one experienced implant impingement at the infraorbital border. Conclusion: Our study provides level II evidence supporting the use of 3D navigation to improve surgical outcomes in complex orbital reconstruction.

Usability testing of a novel interlocking three-dimensional miniplate for mandibular angle fractures

  • Prasetyanugraheni Kreshanti;Aria Kekalih;Ahmad Jabir Rahyussalim;Sugeng Supriadi;Bambang Pontjo Priosoeryanto;Deni Noviana;Mendy Hatibie Oley;Chaula Luthfia Sukasah
    • 대한두개안면성형외과학회지
    • /
    • 제25권4호
    • /
    • pp.171-178
    • /
    • 2024
  • Background: We developed a novel interlocking three-dimensional (3D) miniplate design with an adjustable configuration. As this device is new, surgeons must become familiar with its application. This study evaluated the usability and learning curves associated with the novel interlocking 3D miniplate for mandibular fracture fixation. Methods: The study participants, nine plastic surgeons, were asked to apply an interlocking 3D miniplate and a standard miniplate to polyurethane mandible models. The participants had completed the Basic Craniomaxillofacial Osteosynthesis course during residency and had operated on craniomaxillofacial fractures within the past 5 years. They were instructed to place the interlocking 3D miniplate three times and the standard miniplate once. We assessed the time required for implant placement, the comfort level of the surgeons, and the biomechanical stability of the plates. Biomechanical testing was conducted by subjecting the mandible to forces ranging from 10 to 90 N and the displacement was measured. Results: The results indicate increasing comfort with each attempt at placing the interlocking 3D miniplate, with a significant difference between the first and third attempts. Additionally, a reduction in application time was noted with repeated attempts, suggesting improved efficiency. Biomechanical tests showed comparable stability between the tested plates. Conclusion: Multiple attempts at applying the interlocking 3D miniplate resulted in increased comfort and reduced application time. These findings indicate that, despite its novelty, the interlocking 3D miniplate is relatively straightforward to apply and has a short learning curve. However, surgeons must have specific qualifications to ensure proper training and minimize errors during placement.

선천성 악골유합증 (Syngnathia: Review of literature and a case report)

  • 이종호;김용훈;서병무;최진영;정필훈;김명진
    • 대한구순구개열학회지
    • /
    • 제4권1호
    • /
    • pp.45-53
    • /
    • 2001
  • 악골유합증은 두경부의 매우 드문 선천적 기형으로, 상악과 하악간의 골성 유합이 그 특징이다. 저자들은 좌측 상악, 하악 및 관골궁의 골성 유합을 보이는 1 예를 경험하였고, 골성 유합의 분리를 위한 수술을 시행하였으며, 이후 장기 예후 관찰기간중 개구제한의 점차적인 재발을 관찰하였기에 이에 보고하는 바이다.

  • PDF

악안면 골신장술의 치료계획을 위한 3차원 시뮬레이션 프로토콜의 개발 (Development of Computer Assisted 3-D Simulation and Prediction Surgery in Craniofacial Distraction Osteogenesis)

  • 팽준영;이지호;이종호;백승학;김명진
    • 대한구순구개열학회지
    • /
    • 제6권2호
    • /
    • pp.91-105
    • /
    • 2003
  • There are significant limitations in the precision of mandibular distraction in setting a desired occlusal and facial esthetic outcome. The purpose of this study is to present the simulation method for the distraction osteogenesis treatment planning. 3-D surgery simulation software programs V-works and V-Surgery(Cybermed, Seoul, Korea) were used from the 3D CT data in addition to the conventional data facial photography, panorama and cephalogram, dental cast model. We have utilized already for the various surgical procedures to get information preoperatively for the maxillofacial surgery like cancer localization and reconstructive surgery, orthognathic surgery and implant surgery in the department of Oral and Maxillofacial surgery, Seoul National University Hospital. On the software, bone cutting can be done at any place and any direction. Separated bone segment can be mobilized in all 3 dimensional direction. After the 3D simulation on the software program, mock surgery on the RP model can be performed. This planning method was applied to two hemifacial microsomia patients. With this protocol, we could simulate the movement of bony segment after maxillofacial distraction osteogenesis

  • PDF

구강내 이상소견과 언어 장애를 보이는 Kabuki 증후군환자의 증례보고 (KABUKI SYNDROME WITH PHONETIC & DENTAL PROBLEM: A CASE REPORT)

  • 이종석;고승오;임대호;백진아;신효근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권6호
    • /
    • pp.681-683
    • /
    • 2007
  • Kabuki(Niikawa-Kuroki) syndrome was first reported by Niikawa et al(1981). The faces of the patients are similar to the make-up of traditional Japanese Kabuki actors: long palpebral fissures, an ectropium of the lateral third of the eyelids, and arching eyebrows with sparse lateral halves. Craniofacial findings include a depressed nasal tip, short nasal septum, large and prominent ears, and micrognathia. Other main features area mild to moderate mental deficiency, short stature, skeletal and dermatoglyphic abnormalities, including prominent finger tip pads. Oral anomalies are common in KS(over 60%) and include abnormal dentition, widely spaced teeth, cleft palate or lip, high vault of palate, hypodontia, conical incisors, screw driver-shaped incisors and ectopic upper 6-year molars. The increased occurrence of cleft lip and palate or the development of a high vault of palate has been described by a number of authors. This condition is believed to be common in Japan, but has been reported from other parts of the world. The objective of this presentation is to report a case of this syndrome in six-year-old girl, with characteristic findings.

Sequential treatment for a patient with hemifacial microsomia: 10 year-long term follow up

  • Seo, Jeong-Seok;Roh, Young-Chea;Song, Jae-Min;Song, Won-Wook;Seong, Hwa-Sik;Kim, Si-Yeob;Hwang, Dae-Seok;Kim, Uk-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.3.1-3.7
    • /
    • 2015
  • Hemifacial microsomia (HFM) is the most common craniofacial anomaly after cleft lip and cleft palate; this deformity primarily involves the facial skeleton and ear, with either underdevelopment or absence of both components. In patients with HFM, the management of the asymmetries requires a series of treatment phases that focus on their interception and correction, such as distraction osteogenesis or functional appliance treatment during growth and presurgical orthodontic treatment followed by mandibular and maxillary surgery. Satisfactory results were obtained in a 9-year-old girl with HFM who was treated with distraction osteogenesis. At the age of 19, genioplasty and mandible body augmentation with a porous polyethylene implant (PPE, $Medpor^{(R)}$, Porex) was sequentially performed for the functional and esthetic reconstruction of the face. We report a case of HFM with a review of the literature.

Hypodontia and Hyperdontia of Permanent Teeth in Korean Schoolchildren

  • Moon Hyock-Soo;Cho Sun-Chul;Choung Pill-Hoon
    • 대한구순구개열학회지
    • /
    • 제4권2호
    • /
    • pp.19-27
    • /
    • 2001
  • This study was performed to determine the prevalence of hypodontia and hyperdontia of permanent teeth among Korean schoolchildren, and to compare differences in the prevalence between Korea, other country, and other ethnic groups. The sample consisted of 346 girls aged 6.9~0.3 yr and 375 boys aged 6.8~0.4 yr on whom a panoramic radiograph was taken at Yeonchun-Gun community in Korea. The prevalence of congenitally missing teeth (third molars excluded) was 6.7% in boys and somewhat higher, 9.5% in girls, and 8.0% for both sexes combined. On the average, number of missing teeth per affected child was 1.9 teeth. The most commonly congenitally missing teeth were the mandibular second premolar (32.7%), followed by the mandibular incisor (28.7%), the maxillary second premolar (16.7%), and the maxillary lateral incisors (10.2%). The prevalence of supernumerary teeth was 2.1 % in boys, 1.4% in girls, and 1.8% for both sexes combined. The most common supernumerary teeth were the mesiodens (76.9%), followed by the supernumerary premolar (23.1 %). The affected male-female ratio was 1.6: 1.0. The prevalence of congenital missing teeth in this study was similar to in studies of Japanese, Danish, American and German. The frequency of hyperdontia was lower in this study than in studies of Chinese children, Japanese and American.

  • PDF