• Title/Summary/Keyword: cracks in concrete slab

Search Result 128, Processing Time 0.03 seconds

Experimental Study on Shear Capacity of I-slab System Using Slim Precast Slab Deck (슬림 프리캐스트 슬래브 데크를 사용한 I-슬래브 시스템의 전단 성능에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.126-133
    • /
    • 2017
  • This paper presents the shear capacities of hollow slab with plate and octagonal pillar type hollow sphere. Recently, the interest in precast hollow slab system for buildings is growing up according to the demand for high quality control and the increase in slab thickness. A hollow slab system is widely known as one of the effective slab system which can reduce self-weight of slab. However, hollow slabs are vulnerable to the deterioration in the shear strength due to the decrease of concrete at slab web which resists shear. Especially, in case of precast hollow slabs, it has joint surface between precast concrete slab modules along transverse axis of slab, and shear failure, that is caused by cracks at joints, has to be prevented. Therefore, in this study, shear capacity of the I-slab system is evaluated by 3-points-supported shear test along the longitudinal and transverse axis of slab specimen. Test results showed that I-slab had enough shear strength compared to theoretical shear strength even if it included the joint surfaces.

Longitudinal anti-cracking analysis for post-tensioned voided slab bridges

  • Zhou, Zhen;Meng, Shao-Ping;Liu, Zhao
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.459-473
    • /
    • 2012
  • Post-tensioned concrete voided slab girders are widely used in highway bridge constructions. To obtain greater section hollow rate and reduce the self-weight, the plate thickness of slab girders are designed to be small with the adoption of flat anchorage system. Since large prestress is applied to the anchor end section, it was found that longitudinal shear cracks are easy to occur along the voided slab girder. The reason is the existence of great shearing effect at the junction area between web and bottom (top) plate in the anchor end section. This paper focuses on the longitudinal anti-cracking problem at the anchor end of post-tensioned concrete voided slab girders. Two possible models for longitudinal anticracking analysis are proposed. Differential element analysis method is adopted to derive the solving formula of the critical cracking state, and then the practical analysis method for longitudinal anti-cracking is established. The influence of some factors on the longitudinal anti-cracking ability is studied. Results show that the section dimensions (thickness of bottom, web and top plate) and prestress eccentricity on web plate are the main factors that influence the anti-cracking ability. Moreover, the proposed method is applied into three engineering examples to make longitudinal anti-cracking verification for the girders. According to the verification results, the design improvements for these girders are determined.

Ductility of concrete slabs reinforced with low-ductility welded wire fabric and steel fibers

  • Tuladhar, Rabin;Lancini, Benjamin J.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.4
    • /
    • pp.449-461
    • /
    • 2014
  • The use of low-ductility welded wire fabric (WWF) as a main tensile reinforcement in concrete slabs compromises the ductility of concrete structures. Lower ductility in concrete structures can lead to brittle and catastrophic failure of the structures. This paper presents the experimental study carried out on eight simply supported one-way slabs to study the structural behavior of concrete slabs reinforced with low-ductility WWF and steel fibers. The different types of steel fibers used were crimped fiber, hooked-end fiber and twincone fiber. The experimental results show that the ductility behavior of the slab specimens with low-ductility reinforcement was significantly improved with the inclusion of $40kg/m^3$ of twincone fiber. Distribution of cracks was prominent in the slabs with twincone fiber, which also indicates the better distribution of internal forces in these slabs. However, the slab reinforced only with low-ductility reinforcement failed catastrophically with a single minor crack and without appreciable deflection.

An Experimental Study on Reinforced Effect Using Double Adhensive Panels in Bridge Deck Slabs (프리케스트판을 이용한 교량상판 단면증설 보강공법에 관한 실험적 연구)

  • 박정기;하경민;지한상;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.791-796
    • /
    • 2000
  • Purpose of this study is to analyze the characteristics and reinforcement effects of restored the RC bridge deck with small precast panel through static load tests and to provide the basic information for the damaged slab decks. In the tests for realizing movement of general RC bridge slabs, 6 samples are prepared and tested. All reinforced samples are restored with 1 or 2-layers precast panels by epoxy mortar. The movement of restored slabs is analyzed and compared with the behavior of non-restored slabs. In result of these tests, tension cracks due to bending moment are show, and after static load test there happens finally a punching shear failure, which is the general type of RC bridge failure. The tests show that restoration of the RC slab results in increasing of loading capacity about 30~50% an restoring panels are stick to slab and moving with slab under loading test.

  • PDF

Long-term monitoring of a hybrid SFRC slab on grade using recycled tyre steel fibres

  • Baricevic, Ana;Grubor, Martina;Paar, Rinaldo;Papastergiou, Panos;Pilakoutas, Kypros;Guadagnini, Maurizio
    • Advances in concrete construction
    • /
    • v.10 no.6
    • /
    • pp.547-557
    • /
    • 2020
  • This paper presents one of the demonstration projects undertaken during the FP7 EU-funded Anagennisi project (Innovative reuse of all tyre components in concrete-2014-2017) on a full-scale (30 m×40 m, thickness: 0.2 m) Steel Fibre Reinforced Concrete (SFRC) slab-on-grade using a blend of manufactured steel fibres (MSF) and Recycled Tyre Steel Fibres (RTSF). The aim of the project was to assess the use of RTSF in everyday construction practice. The Anagennisi partners, Dulex Ltd in collaboration with Gradmont-Gradacac Ltd and University of Zagreb, designed, cast and monitored the long-term shrinkage deformations of the indoor slab-on-grade slab at Gradmont's precast concrete factory in Gradacac, Bosnia and Herzegovina. A hybrid RTSF mix (20 kg/㎥ of MSF+10 kg/㎥ of RTSF) was used to comply with the design criteria which included a maximum load capacity of 20 kN/㎡. The slab was monitored for one year using surveying equipment and visual inspection of cracks. During the monitoring period, the slab exhibited reasonable deformations (a maximum displacement of 3.3 mm for both, horizontal and vertical displacements) whilst after five years in use, the owners did not report any issues and were satisfied with the construction methodology and materials used. This work confirms that RSTF is a viable and sustainable solution for slab-on-grade applications.

Behaviors of Early-Age Cracks on the JCP (무근 콘크리트포장 초기균열 거동 연구)

  • Park, Dae-Geun;Suh, Young-Chan;Ann, Sung-Sun;Kim, Hyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.6 no.2 s.20
    • /
    • pp.47-59
    • /
    • 2004
  • The temperature variation of concrete pavement at early-age significantly affects the initiation and propagation of its early-age cracks. This implies that the measurement and analysis of early age temperature trend are necessary to examine the causes of early age cracks in the concrete pavement. In this study, it is investigated how the early age temperature trend in concrete pavement affects the random crack initiation and behaviors of saw-cut joints using the actual construction site which is located at the KHC test road. During 72 hours after placing the concrete pavement, the ambient air temperature and temperatures at the top, middle, and bottom in concrete pavement were measured and the random crack initiation in concrete slabs and early age behaviors in the joints were surveyed. The investigation results indicate that the first random crack was initiated at one of the slabs placed in the early morning which have higher temperature changes during early 72 hours. The movement of slab was influenced by the early-age crack in the joint. It suggested that the different occurrence time of the cracks in the joint had an influence on the behavior of the cracks. Besides, the slab constructed In the morning had higher possibility of crack initiation than that in the afternoon. The rarely occurred cracks had bigger gap than other cracks.

  • PDF

Thermal Stress Analysis on the Heat of Hydration Considering Creep and Shrinkage Effects of Mass Concrete (크리이프와 건조수축영향을 고려한 매스콘크리트에서 수화열에 대한 온도응력해석)

  • 김진근;김국한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.107-113
    • /
    • 1992
  • The heat of hydration of cement the causes the internal temperature rise at early age, particulary in massive concrete structures such as a mat-slab of nuclear reactor building or a dam or a large footing. As the result of the temperature rise and restraint of foundation, the thermal stress enough to induce concrete cracks can occur. Therefore, the prediction of the thermal stress is very important in the design and construction stages in order to control the cracks developed in massive concrete structures. And, more creep and shrinkage take place at elevated temperatures in young concrete, Thus the effect of creep and shrinkage must be considered for checking the safety and servicebility(crack, durability and leakage).

  • PDF

Analysis of Joint Behavior in Cement Concrete Pavements (시멘트 콘크리트 포장체 줄눈부의 거동해석)

  • 변근주;이상민;임갑주;한봉완
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.1-6
    • /
    • 1990
  • Joints are provided in cement concrete pavements to control transverse and longitudinal cracking that occur due to restrained deformations caused by moisture and temperature variations in the slab. But the construction of joints reduces the load-carrying capacity of the pavement at the joints, and pavements have beem deteriorated by cracks at the slab edges along the joints due to traffic loads. Therefore, it is important to analyze the behavior of joints accurately in the design of cement concrete pavements. In this study, the mechanical behavior of cement concrete pavement slabs is analyzed by the plate-finite element model, and Winkler foundation model is adopted to analyze the subgrades. The load transfer mechanism of joints are composed of dowel action, aggregate interlocking, and tied-key action, and the analytical program is developed using these joint models.

  • PDF

Horizontal Cracks in Continuously Reinforced Concrete Pavement Structures (연속철근콘크리트 도로포장 구조물의 내부 수평균열)

  • Kim, Seong-Min;Cho, Byoung-Hooi;Kwon, Soon-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.425-429
    • /
    • 2006
  • Horizontal cracks at the mid-depth of concrete slabs were observed at a section of the continuously reinforced concrete pavement(CRCP) structures on the Korea Highway Corporation's Test Road. To investigate the existence and the extent of horizontal cracks in the concrete slab, a number of cores were taken from the section of CRCP. To identify the causes of horizontal cracks, numerical analyses were conducted. Several variables relative to design, material, and environment were considered in the studies to evaluate possible causes of horizontal cracking. A numerical model of CRCP was developed using the finite element discretization, and the shear and normal tensile stress distributions in CRCP were investigated with the model. Numerical analysis results show that the maximum shear and normal tensile stresses develop near the depth of steel bars at transverse cracks. If those maximum stresses reach the strength of concrete, horizontal cracks occur. The maximum stresses become higher as the environmental loads, coefficient of thermal expansion of concrete, and elastic modulus of concrete increase.

Analysis on IBEM for consideration on reinforced concrete slab resistance

  • Kyung, Je-Woon;Tae, Sung-Ho;Lee, Han-Seung;Lee, Sung-Bok
    • Computers and Concrete
    • /
    • v.5 no.6
    • /
    • pp.545-558
    • /
    • 2008
  • The corrosion of RC structures demonstrates very complicated forms of deterioration intermingled together but all pointing to a decrease in the durability of RC structures due to the corrosion of reinforcing bars. Until now, nondestructive techniques, such as half-cell potential and polarization resistance, have been widely available in the world. The former provides information on the probability of corrosion while the latter is associated with information concerning corrosion rates. Inversion by the boundary element method (IBEM) was developed for considering concrete resistivity. The applicability of the procedure was examined through a numerical analysis and electrolytic tests for RC slabs. A distribution in such concrete resistivity is relatively inhomogeneous including cracks on the surface of slabs. Regarding cracks in concrete, the relative coefficient of concrete resistance was introduced to perform its analysis. Further, the procedure will be developed to identify the corroded region visually using 3-D VRML.