Browse > Article
http://dx.doi.org/10.12989/sem.2014.49.4.449

Ductility of concrete slabs reinforced with low-ductility welded wire fabric and steel fibers  

Tuladhar, Rabin (School of Engineering and Physical Sciences, James Cook University)
Lancini, Benjamin J. (GHD)
Publication Information
Structural Engineering and Mechanics / v.49, no.4, 2014 , pp. 449-461 More about this Journal
Abstract
The use of low-ductility welded wire fabric (WWF) as a main tensile reinforcement in concrete slabs compromises the ductility of concrete structures. Lower ductility in concrete structures can lead to brittle and catastrophic failure of the structures. This paper presents the experimental study carried out on eight simply supported one-way slabs to study the structural behavior of concrete slabs reinforced with low-ductility WWF and steel fibers. The different types of steel fibers used were crimped fiber, hooked-end fiber and twincone fiber. The experimental results show that the ductility behavior of the slab specimens with low-ductility reinforcement was significantly improved with the inclusion of $40kg/m^3$ of twincone fiber. Distribution of cracks was prominent in the slabs with twincone fiber, which also indicates the better distribution of internal forces in these slabs. However, the slab reinforced only with low-ductility reinforcement failed catastrophically with a single minor crack and without appreciable deflection.
Keywords
concrete; ductility; fiber reinforced concrete; welded wire fabric;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Falkner, H. and Teutsch, M. (1993), Comparative Investigations of Plain and Steel Fibre Reinforced Industrial Ground Slabs, Institut Fur Baustoffe, Massivbau and Brandschutz, Technical University of Brunswick, Germany.
2 Lok, T.S. and Pei, S.J. (1998), "Flexural behaviour of steel fiber reinforced concrete", J. Mater. Civil Eng., 10, 86-97.   DOI   ScienceOn
3 Roesler, J.R., Lange, D.A., Altoubat, S.A., Rieder, K.A. and Ulreich, G.R. (2004), "Fracture of plain and fiber-reinforced concrete slabs under monotonic loading", J. Mater. Civil Eng., ASCE, 16, 452-460.   DOI   ScienceOn
4 Khaloo, A.R. and Afshari, M. (2005), "Flexural behaviour of small steel fiber reinforced concrete slabs", Cement Concrete Compos., 27, 141-149.   DOI   ScienceOn
5 Falkner, H., Huang, Z. and Teutsch, M. (1995), "Comparative study of plain and steel fiber reinforced concrete ground slabs", Concrete Int., 17(1), 45-51.
6 Smith, S.T. and Gilbert, R.I. (2003), "Tests on RC slabs reinforced with 500 MPa welded wire fabric", Austr. J. Civil Eng., 1(1), 69-75.
7 Patrick, M. (2005), "Safe design of slabs incorporating class L mesh: latest design advice about AS3600", SRIA Technical Paper, 23-27.
8 Gilbert, R.J. and Smith, S.T. (2006), "Strain localization and its impact on the ductility of reinforced concrete slabs containing 500 MPa reinforcement", Adv. Struct. Eng., 9(1), 117-127.   DOI   ScienceOn
9 Gilbert, R.I. and Sakka, Z.I. (2007), "Effect of reinforcement type on the ductility of suspended reinforced concrete slabs", J. Struct. Eng., ASCE, 133(6), 834-843.   DOI   ScienceOn
10 Gilbert, R.I. (2009), "Restrictions on the use of Class L reinforcement in AS3600-2009", Concrete Australia, 35(3), 31- 36.
11 Foster, S. and Kilpatrick, A. (2008), "The use of low ductility welded wire mesh in the design of suspended reinforced concrete slabs", Austr. J. Struct. Eng., 8(3), 237-248.   DOI
12 AS/NZS 4671 (2001), Steel reinforcing materials, Standards Australia/ Standard New Zealand, Sydney.
13 AS1012.9 (1999), Methods of testing concrete: Determination of the compressive strength of concrete specimens, Standards Australia, Sydney.
14 Warner, R.F., Rangan, B.V., Hall, A.S. and Faulkes, K.A. (1998), Concrete Structures, Longman, Melbourne, Australia.
15 AS3600 (2009), Concrete structures, Standards Australia, Sydney.
16 Kilver, J. (2004), Ductility Requirements for Reinforced Concrete Structures, Institut fur Massivbau and Baustofftechnologie, Universitat Leipzig, LACER No. 9.
17 AS1012.11 (2000), Methods of testing concrete: Determination of the modulus of rupture, Standards Australia, Sydney.
18 Sakka, Z. (2009), "Impact of steel ductility on the structural behaviour and strength of RC slabs", Ph.D. Dissertation, University of New South Wales, Sydney.
19 CIA (2003), Fibers in Concrete: Current Practice Note 35, Concrete Institute of Australia, Australia.