• Title/Summary/Keyword: coupling unit

Search Result 174, Processing Time 0.032 seconds

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Design Equation of a Coupled Beam to Limit Deflection of Modular Unit Structures (모듈러 유닛 구조물의 사용성 향상을 위해 연결된 보의 처짐 제한을 위한 설계식 개발)

  • Park, Ji-Hun;An, Seok-Hyun;Cho, Bong-Ho;Lee, Sang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.471-475
    • /
    • 2007
  • Design equations of coupling plates, which connects floor beam of the upper modular unit and overhead beam of the lower one in order to improve serviceability in vibration, are proposed. End conditions of the coupled beams is semi-rigid and the optimal location of the coupling plates are assumed. Rotational constraints for both ends of the coupling plate modeled with beam elements are released and flexibility method is applied to obtain deflection equations of the coupled beam. Proposed equations are defined using the flexibility of the coupling plate, of which size can be determined inversely. Based on numerical analysis, coefficients of the design equations are calibrated and the revised equations are verified to be useful in the design of the coupled beam.

  • PDF

Design and Analysis of Diffractive Grating Imprinted Light-guide Plate for LCD Illumination

  • Choi, Hwan-Young;Park, Young-Pil
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.7-15
    • /
    • 2004
  • A highly simplified backlight unit mainly composed of diffractive grating in sub-micron order imprinted light-guide plate (LGP) is proposed for edge-lit backlight unit. Optical characteristics of the imprinted LGP are examined by RCWA and the performance is verified through Monte Carlo simulation. Results show that the diffraction efficiency, luminous flux and its uniformity over the area are significantly affected by the angle of incident ray. Consequently couples of design considerations are additionally proposed to enhance luminous flux. In terms of peak luminance and out-coupling luminous flux, the experimental results are agreed well with the performance simulation. Finally, compared with optical characteristics of conventional backlight unit, we could conclude that the proposed simplified backlight unit made of diffractive grating imprinted light-guide plate is a good substitute for the conventional backlight unit.

Design of Capacitive Power Transfer Using a Class-E Resonant Inverter

  • Yusop, Yusmarnita;Saat, Shakir;Nguang, Sing Kiong;Husin, Huzaimah;Ghani, Zamre
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1678-1688
    • /
    • 2016
  • This paper presents a capacitive power transfer (CPT) system using a Class-E resonant inverter. A Class-E resonant inverter is chosen because of its ability to perform DC-to-AC inversion efficiently while significantly reducing switching losses. The proposed CPT system consists of an efficient Class-E resonant inverter and capacitive coupling formed by two flat rectangular transmitter and receiver plates. To understand CPT behavior, we study the effects of various coupling distances on output power performance. The proposed design is verified through lab experiments with a nominal operating frequency of 1 MHz and 0.25 mm coupling gap. An efficiency of 96.3% is achieved. A simple frequency tracking unit is also proposed to tune the operating frequency in response to changes in the coupling gap. With this resonant frequency tracking unit, the efficiency of the proposed CPT system can be maintained within 96.3%-91% for the coupling gap range of 0.25-2 mm.

An integrated design approach for Light Guide Panel(LGP) of Back Light Unit(BLU) to improve the Optical Performance of Liquid Crystal Display(LCD) (LCD 제품의 광학 성능 향상을 위한 백라이트 유닛용 도광판의 최적설계)

  • Lee, Gab-Seong;Jeong, Jae-Ho;Yoon, Sang-Joon;Choi, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1048-1052
    • /
    • 2008
  • Difficulties in developing process of Liquid Crystal Display(LCD) products such as frequent design modifications, various design requirements, and short-term development period bring on the need of integrated design approach that is efficient and easy to handle. Back Light Unit(BLU) of the LCD, which drastically affects the optical performance of LCD products, is divided into in-coupling part and out-coupling part. Serration of the in-coupling part flattens the light received from point light sources and dot pattern of the out-coupling part regularizes the light sent to screen. Therefore, the optical performance of a LCD product is largely influenced by the shape of serration and the arrangement of dot pattern. In this research, a new design approach which enables to improve the optical performance of LCD products and overcome the prementioned difficulties in developing process of LCD products is proposed. The shape of serration is parameterized to 3 parameters and out-coupling part is partitioned into 10 partitions to apply the optimization technique to this problem. 3 parameters for the shape of serration and densities of 10 partitions are used as design variables in the design optimization. Optical simulation tool named SPEOS is used to evaluate the optical performance of the LCD product. Since the optical simulation uses the random ray tracing technique, numerical noise may possibly be included in the simulation process. To solve the problem caused by numerical noise, the PQRSM which can stably find the solution of the noise problem is used in this research.

  • PDF

Development of Bypass Unit for Ship Area Network Based on Legacy-line Communication (무배선 통신을 위한 선박 네트워크용 바이패스 장치 개발)

  • Jun, Ho-Ik;Kim, Hyun-Sik;Jung, Kyun Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.292-297
    • /
    • 2015
  • In this paper, we reported the bypass unit for ship area networks in order to detour the communication failure regions and poor communication links. The device was composed of three parts of circuits for power cut-off, protection, and coupling transformer. Since the coupling transformer exerts a dominant influence on the performance of the by-pass unit, we have tried to find the optimal magnetic core materials and its dimensions. The prototype was passed through the performance test of insertion loss, temperature, and vibration characteristics. The insertion loss was around -2 dB in the range of 90 kHz ~ 30 MHz and the average communication speed was 59.2 Mbps in the laboratory. A pilot communication test using the developed tool was conducted in the training ship of the Korea Maritime and Ocean University. As a results of experiment, we showed that the wired communication among the heterogeneous-links in the ship area networks are possible by the bypass unit and also a high speed communication services are available in ~ Mbps by using a power-line.

Influence of reinforcing systems and microstructures of SBR on water swelling behaviors of SBR composites (충전 시스템과 SBR의 미세 구조가 SBR 복합체의 수팽윤 거동에 미치는 영향)

  • Choi, Sung-Seen;Ha, Sung-Ho
    • Elastomers and Composites
    • /
    • v.42 no.2
    • /
    • pp.102-106
    • /
    • 2007
  • Water swelling behaviors of SBR vulcanizates with different reinforcing systems of carbon black, silica without a coupling agent, and silica containing a coupling agent were studied. Distilled water and 3.5% NaCl solution were used as swelling media. The water swelling ratios in the distilled water were higher than those in the salt solution. The water swelling ratios of the carbon black-filled samples were lower than those of the silica-filled ones. For the silica-filled SBR vulcanizates, the specimens without the silane coupling agent had higher water swelling ratios than those containing it. Water swelling behaviors of SBR composites with different 1,2-unit contents were also compared. The water swelling ratios tended to decrease by increasing the 1,2-unit content.

Current Limiting effects of a Flux-Coupling Type SFCL according to applied voltage (자속결합형 초전도 한류기의 인가전압별 전류제한 효과)

  • Jung, Byung-Ik;Choi, Hyo-Sang;Cho, Yong-Sun;Lee, Joo-Hyoung;Jung, Su-Bok;Oh, Kum-Gon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.249-251
    • /
    • 2008
  • We investigated a flux-coupling type superconducting fault current(SFCL) limiter. The SFCL consisted of the primary and secondary coils, which were wound in series each other through an iron core. Superconducting unit was connected with secondary coil in parallel. The flux generated from a coil in normal operation is cancelled out by its structure and the zero resistance of the superconducting unit. In this paper. In order to compare the current limiting effects of the SFCL by applied voltage. When a lied voltage was increased, quench time was shortened Fast quench time is important component under the same fault condition because power burden of the SFCL is reduced by that of the superconducting units. The current limiting behavior of flux-coupling type SFCL was dependent upon the applied voltage.

  • PDF

A modularized numerical framework for the process-based total system performance assessment of geological disposal systems

  • Kim, Jung-Woo;Jang, Hong;Lee, Dong Hyuk;Cho, Hyun Ho;Lee, Jaewon;Kim, Minjeong;Ju, Heejae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2828-2839
    • /
    • 2022
  • This study developed a safety assessment tool for geological disposal systems called APro, a systemically integrated modeling system based on modularizing and coupling the processes which need to be considered in a geological disposal system. Thermal, hydraulic, chemical, canister failure, radionuclide release and transport processes were considered in the current version of APro. Each of the unit processes in APro consists of a single Default Module, and several Alternative Modules which can increase the flexibility of the model. As an initial stage of developing the modularization concept and modeling interface, the Default Modules of each unit process were described, with one Alternative Module of chemical process. The computation part of APro is mainly a MATLAB workspace controlling COMSOL and PHREEQC, which are coupled by an operator splitting scheme. The APro model domain is a stylized geological disposal system employing the Swedish disposal concept (KBS-3 type), but the repository layout can be freely adjusted. In order to show the applicability of APro to the total system performance assessment of geological disposal system, some sample simulations were conducted. From the results, it was confirmed that coupling of the thermal and hydraulic processes and coupling of the canister failure and the radionuclide release processes were well reflected in APro. In addition, the technical connectivity between COMSOL and PHREEQC was also confirmed.