• Title/Summary/Keyword: coupling beams

Search Result 188, Processing Time 0.024 seconds

Behavior and Design of Steel-Concrete Composite Coupling Beams (철골-콘크리트 합성 연결보의 거동과 설계)

  • 홍성걸;양지연
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.433-438
    • /
    • 2003
  • Structural steel/composite beams provide a viable alternative for coupling individual reinforced concrete wall piers. Well-established guidelines for shear links in eccentrically braced steel frames form the basis of current design guidelines. However, these provisions ignore the effects of nominally reinforced concrete encasement which typically surrounds the coupling beam, and are based on overly conservative assumed deformation demand. A coordinated analytical research program at here has focused on response of steel/composite coupling beams, their connections to reinforced concrete walls, and overall behavior of composite coupled wall systems. Using the results from this study, guidelines for proper design and detailing of steel/composite coupling beams and beam-wall connections have been developed. This paper summarizes the research program, and highlights the basic concepts, important findings, and recommendations.

  • PDF

Experimental study on seismic performance of coupling beams not designed for ductility

  • Lam, S.S.E.;Wu, B.;Liu, Z.Q.;Wong, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.3
    • /
    • pp.317-334
    • /
    • 2008
  • Seismic performance of coupling beams not designed for ductility is examined. Eight 1:4 scale coupling beam specimens, with seven reinforced concrete sections and one composite section, were tested under cycles of push-pull action. Characteristics of the specimens include moderate shear span ratio in the range of 2.5-3.5, high main reinforcement ratio at 3-4% and small to large stirrup spacing with 90- degree hooks. All the reinforced concrete specimens failed in a brittle manner. Displacement ductility of specimens with large stirrup spacing (${\geq}$140 mm) is in the range of 3 to 5. Seismic performance of the specimens is also examined using the ultimate drift angle and the amount of energy dissipated. Correlating the test data, an empirical relationship is proposed to estimate the ultimate drift angle of a class of coupling beams considered in the study not designed for ductility.

Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars (세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능)

  • Kim, Sun-Woo;Jang, Seok-Joon;Yun, Hyun-Do;Seo, Soo-Yeon;Chun, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • As per current seismic design codes, diagonally reinforced coupling beams are restricted to coupling beams having aspect ratio below 4. However, a grouped diagonally reinforcement detail makes distribution of steel bars in the beam much harder, furthermore it may result in poor construction quality. This paper describes the experimental results of concrete coupling beam reinforced with high-strength steel bars (SD500 & SD600 grades). In order to improve workability for fabricating coupling beams, a headed large diameter steel bar was used in this study. Two full-scale coupling beams were fabricated and tested with variables of reinforcement details and aspect ratio. To reflect real behavior characteristic of the beam coupling shear walls, a rigid steel frame system with linked joints was set on the reaction floor. As a test result, it was noted that cracking and yielding of reinforcement were initially progressed at the coupling beam-to-shear wall joint, and were progressed to the mid-span of the coupling beam, based on the steel strain and failure modes. It was found that the coupling beams have sufficient deformation capacity for drift ratio of shear wall corresponding to the design displacement in FEMA 450-1. In this study, the headed horizontal steel bar was also efficient for coupling beams to exhibit shear performance required by seismic design codes. For detailed design for coupling beam reinforced with high-strength steel, however, research about the effect of variable aspect ratios on the structural behavior of coupling beam is suggested.

Behavioral Characteristics and Energy Dissipation Capacity of Short Coupling Beams with Various Reinforcement Layouts (다양한 배근상세를 갖는 짧은 연결보의 주기거동 특성과 에너지소산능력의 평가)

  • Eom, Tae-Sung;Park, Hong-Gun;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.203-212
    • /
    • 2008
  • The cyclic behavior and energy dissipation mechanism of short coupling beams with various reinforcement layouts were studied. For numerical analysis of coupling beams, nonlinear truss model was used. The results of numerical analysis showed that the coupling beams with conventional reinforcement layout showed pinched cyclic behavior without significant energy dissipation, whereas the coupling beams with diagonal reinforcement exhibited stable cyclic behavior without pinching. The energy dissipation of the coupling beams was developed mainly by diagonal reinforcing bars developing large plastic strains rather than concrete which is a brittle material Based on this result, simplified equations for evaluating the energy dissipation of coupling beams were developed. For verification, the predicted energy dissipation was compared with the test results. The results showed that the simplified equations can predict the energy dissipation of short coupling beams with shear span-to-depth ratio less than 1.25 with reasonable precision, addressing various design parameters such as reinforcement layout, shear span-to-depth ratio, and the magnitude of inelastic displacement. The proposed energy equations can be easily applied to performance-based seismic evaluation and design of reinforced concrete structures and members.

Effect of Reinforcement Details on the Seismic Performance of Precast HPFRCC Coupling Beams (보강상세에 따른 프리캐스트 HPFRCC 커플링 보의 내진성능)

  • Kim Sun Woo;Yun Hyun Do;Park Wan Shin;Jeon Esther
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.81-84
    • /
    • 2005
  • In order to effectively resist seismic loads, coupling beams must be sufficiently stiff, strong and posses a stable load-deflection hysteretic response. This paper reports experimental data on the seismic performance of precast HPFRCC coupling beams with variable details. Precast HPFRCC coupling beam was tested to evaluate their failure modes. shear behavior, micro crack pattern and energy dissipation. Based on the experimental results, precast coupling beam with diagonal and rhombic details offer greater performance and ductility than coupling beam with normal detail.

  • PDF

Behavioral Characteristics and Energy Dissipation Capacity of Coupling Beams Subject to Cyclic Loads (커플링보의 주기거동특성 및 에너지소산능력)

  • Eom, Tae-Sung;Park, Hong-Gun;Kang, Su-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.9-12
    • /
    • 2004
  • Coupling beams subject to cyclic loads exhibit different behavioral characteristics and energy dissipation capacity varying with re-bar layouts. In the present study, nonlinear analysis method was developed using analogous truss model. Using the numerical method, parametric studies were performed to investigate the behavioral characteristics and the energy dissipation mechanism of coupling beams with various re-bar layouts subject to cyclic loading. Based on the investigation, a simple and practical method for evaluating the energy dissipation capacity of coupling beams was developed and verified by experiments. The proposed method accurately predicted the dissipated energy during cyclic loading addressing design parameters such as re-bar layouts, re-bar ratio, and deformation. The proposed method can be easily applied to nonlinear static and dynamic methods for seismic analysis and design.

  • PDF

Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams (Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동)

  • Joo, Jae-Hyung;Chea, Seong-Yun;Kim, Seon-Gyu;Kim, Woo-Jae;Jun, Ho-Min;Park, Hyo-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF

The Shear Strength and Deformability of R/C Coupling Beams using Strut-and-Tie Models (스트럿-타이 모델을 이용한 철근 콘크리트 연결보의 전단강도와 변형능력)

  • Jang, Sang-Ki;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.349-352
    • /
    • 2004
  • In this study, a strut-and-tie models for the coupling beam based on deformations are presented. To design shear-dominated R/C coupling beams, it is important to consider shear strength deterioration with required deformations. This study proposes the method of estimating shear strength of the reinforced concrete coupling beams. The proposed method determines the strain states from target displacements based on the nonlinear truss analysis. The estimated horizontal strain of beam is then used in calculating the strength of the diagonal strut with compatibility conditions. The deterioration of shear strength of the coupling beam depends on the strength degradation of struts due to plastic deformations.

  • PDF

The influence of internal ring beams on the internal pressure for large cooling towers with wind-thermal coupling effect

  • Ke, Shitang;Yu, Wei;Ge, Yaojun;Zhao, in;Cao, Shuyang
    • Wind and Structures
    • /
    • v.28 no.1
    • /
    • pp.1-17
    • /
    • 2019
  • Internal ring beams are primary components of new ring-stiffened cooling towers. In this study, numerical simulation of the internal flow field of a cooling tower with three ring beams under wind-thermal coupling effect is performed. The studied cooling tower is a 220-m super-large hyperbolic indirect natural draft cooling tower that is under construction in China and will be the World's highest cooling tower, the influence of peripheral radiators in operating cooling tower is also considered. Based on the simulation, the three-dimensional effect and distribution pattern of the wind loads on inner surface of the cooling tower is summarized, the average wind pressure distributions on the inner surface before and after the addition of the ring beams are analyzed, and the influence pattern of ring beams on the internal pressure coefficient value is derived. The action mechanisms behind the air flows inside the tower are compared. In addition, the effects of internal ring beams on temperature field characteristics, turbulence kinetic energy distribution, and wind resistance are analyzed. Finally, the internal pressure coefficients are suggested for ring-stiffened cooling towers under wind-thermal coupling effect. The study shows that the influence of internal stiffening ring beams on the internal pressure and flow of cooling towers should not be ignored, and the wind-thermal coupling effect should also be considered in the numerical simulation of cooling tower flow fields. The primary conclusions presented in this paper offer references for determining the internal suction of such ring-stiffened cooling towers.