• 제목/요약/키워드: coupling

검색결과 7,580건 처리시간 0.032초

Effect of two way thermal hydraulic-fuel performance coupling on multicycle depletion

  • Awais Zahur;Muhammad Rizwan Ali;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4431-4446
    • /
    • 2023
  • A Multiphysics coupling framework, MPCORE, has been developed to analyze safety parameters using the best estimate codes. The framework contains neutron kinetics (NK), thermal hydraulics (TH), and fuel performance (FP) codes to analyze fuel burnup, radial power distribution, and coolant temperature (Tbc). Shuffling and rotation capabilities have been verified on the Watts Bar reactor for three cycles. This study focuses on two coupling approaches for TH and FP modules. The one-way coupling approach involves coupling the FP code with the NK code, providing no data to the TH modules but getting Tbc as boundary condition from TH module. The two-way coupling approach exchanges information from FP to TH modules, so that the simplified heat conduction solver of the TH module is not used. The power profile in both approaches does not differ significantly, but there is an impact on coolant and cladding parameters. The one-way coupling approach tends to over-predict the cladding hydrogen concentration (CHC). This research highlights the difference between one-way and two-way coupling on critical boron concentration, Tbc, CHC, oxide surface temperature, and pellet centerline temperature. Overall, MPCORE framework with two-way coupling provides a more accurate and reliable analysis of safety parameters for nuclear reactors.

An Evaluation of the Coupling Coordination Degree of the Yangtze River Delta Port Cluster Based on Coupling Theory

  • Lu Ke;Yong-Sik Oh
    • 한국항해항만학회지
    • /
    • 제48권2호
    • /
    • pp.78-87
    • /
    • 2024
  • To quantitatively assess the correlation between subsystems within a port cluster and the overall coordinated development of the port group, the current paper evaluates the coordinated development of port clusters. First, we construct an evaluation index system for the coupling and coordination of port clusters. Next, we introduce the contribution index of port subsystems, coupling degree, and coupling coordination degree functions to formulate a coupling coordination evaluation model for the port cluster. Finally, we use the Yangtze River Delta port cluster as a case study for validation, specifically using empirical data from 2012 to 2021. The findings reveal distinct phased characteristics in the coupling and coordination of port clusters in the Yangtze River Delta, marked by a notable transition from "maladjustment" to "coordination." Further, sustained high coupling values over a decade indicate a significant level of competition and cooperation among ports within the Yangtze River Delta port cluster. Over time, this competitive and collaborative dynamic has progressively evolved toward a more positive and structured direction. Lastly, it is expected that the evaluation model proposed in this paper can be extrapolated to other port clusters to gauge the extent of coordinated development, thereby facilitating horizontal comparisons and vertical analyses.

커플링제로 처리된 질화규소 분말의 사출성형 (Injection Molding of Silicon Nitride Powders Treated with Coupling Agents)

  • 송휴섭
    • 한국세라믹학회지
    • /
    • 제30권2호
    • /
    • pp.131-138
    • /
    • 1993
  • The effects of silane coupling agents on the injection molding process were investigated using silicone nitride mixtrues with a binder system containing polypropylene as a major binder (55vol% solid loading). The formation of bonding between silicon nitride powder and coupling agents was confirmed through the analyses of powder surface. The use of coupling agents improved mixing characteristics judged by the torque change during mixing process. the coupling agents also reduced molten viscosity of the mixture considerably, which is a main factor to determine the flow of the mixture. However, the bonding between coupling agents and polymers had a negative effect on the debinding process by retarding the thermal decomposition.

  • PDF

GLOBAL COUPLING EFFECTS ON A FREE BOUNDARY PROBLEM FOR THREE-COMPONENT REACTION-DIFFUSION SYSTEM

  • Ham, Yoon-Mee
    • 대한수학회지
    • /
    • 제43권3호
    • /
    • pp.659-676
    • /
    • 2006
  • In this paper, we consider three-component reaction-diffusion system. With an integral condition and a global coupling, this system gives us an interesting free boundary problem. We shall examine the occurrence of a Hopf bifurcation and the stability of solutions as the global coupling constant varies. The main result is that a Hopf bifurcation occurs for global coupling and this motion is transferred to the stable motion for strong global coupling.

묶음 대각철근을 적용한 철근콘크리트 연결보의 이력거동 평가 (Cyclic Behavior of Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement)

  • 한상환;권현욱;신명수;이기학
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2014
  • Diagonal reinforced coupling beam of coupled shear walls can provide sufficient strength and stiffness to resist lateral force. However, the reinforcement details for coupling beams required by ACI 318 (2011) are difficult to construct because of the reinforcement congestion and confined interior area. This study presents experimental results about the seismic performance of coupling beams having bundled diagonal reinforcement to improve the workability. Experiments were conducted using half scaled precast coupling beams having an aspect ratio of 2.0. It was observed that the bundled diagonal reinforced coupling beams can develop seismic performance similar to the coupling beams with requirement details specified in ACI 318 (2011).

A Capacitively Coupled Multi-Stage LC Oscillator

  • Park, Cheonwi;Park, Junyoung;Lee, Byung-Geun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권3호
    • /
    • pp.149-151
    • /
    • 2015
  • Coupling with a ring of capacitors introduces in-phase coupling current in multi-stage LC oscillators, increasing coupling strength and phase spacing accuracy. Capacitive coupling is effective at high-frequency applications because it increases coupling strength with the operating frequency. However, capacitive loading from the ring lowers operating frequency and reduces the tuning range. Mathematical expressions of phase noise and phase spacing accuracy with capacitive coupling are examined here, and transistor-level simulations confirm the effectiveness of the capacitive coupling.

March Test 기법의 한게 및 알고리즘(반도체 메모리의 커플링 고장을 중심으로) (The Limit of the March Test Method and Algorithms (On Detecting Coupling Faults of Semiconductor Memories))

  • 여정모;조상복
    • 전자공학회논문지A
    • /
    • 제29A권8호
    • /
    • pp.99-109
    • /
    • 1992
  • First, the coupling faults of semiconductor memory are classified in detail. The chained coupling fault is introduced and defined, which results from sequential influencing of the coupling effects among memory cells, and its mapping relation is described. The linked coupling fault and its order are defined. Second, the deterministic “Algorithm GA” is proposed, which detects stuack-at faults, transition faults, address decoder faults, unlinked 2-coupling faults, and unlinked chained coupling faults. The time complexity and the fault coverage are improved in this algorithm. Third, it is proved that the march test of an address sequence can detect 97.796% of the linked 2-coupling faults with order 2. The deterministic “Algorithm NA” proposed can detect to the limit. The time complexity and the fault coverage are improved in this algorithm.

  • PDF

정렬불량을 가진 기어 커플링의 동역학적 모델 개발에 관한 연구 (I) - 기어 커플링의 동적모델 구축을 중심으로- (A Study on Development the Dynamic Model to Misaligned Gear Coupling (I) - The Focus on Development of Dynamic Model to n Gear Coupling)

  • 김병옥;김용철
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.857-863
    • /
    • 2003
  • In rotating machinery, unbalance and misalignment are major concerns in vibration. Unbalance can be eliminated by balancing procedure to some degree. but little work has been done on the vibrations that occur in a misaligned rotor system. Currently, no generalized theoretical model based on a rotor system with flexible coupling is available to describe the vibrations caused by misalignment. As a part of systematic investigation on the misalignment, first of all, the study on flexible coupling with misalignment should be preceded. In this study, the geometry and reaction force and moment of a gear coupling with misalignment was investigated, also the theoretical model of a gear coupling with misalignment was presented by using the relationship between geometry and moment of gear coupling. It is expected that the proposed procedure can be applied to derive the theoretical model of other couplings.

벽식 아파트 구조에서 연결슬래브의 거동특성 (The Behavior of Reinforced Concrete Coupling Slab in Wall-Dominant System)

  • 최윤철;최현기;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.61-64
    • /
    • 2006
  • A common form of construction for apartment buildings consists of walls and coupling element. But, the structural behavior of coupling element are very complex and affected by the properties of coupling element. The propose of this paper is to evaluation the behavior of coupling element in wall-dominant system. An 1/2 scale three specimens was constructed and under cyclic loads. The specimen was consisted of opening walls and coupling element as well as floor slabs. From the result of this study, in coupling slabs, the stresses were not uniform across the width. And the effective width of coupling slabs was found smaller than the that of predicted from previous studies.

  • PDF

벽식 아파트 구조에서 연결부재의 거동특성 (The Behavior of Reinforced Concrete Coupling Elements in Wall-Dominant System)

  • 장극관;서대원;천영수
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.83-91
    • /
    • 2002
  • 현재 국내에서 건설되고 있는 대부분의 아파트는 철근콘크리트 전단벽과 연결부재만으로 구성된 순수벽식 구조형식을 취하고 있다. 그러나 이러한 벽식구조의 거동은 매우 복잡하며 연결부재의 영향을 크게 받는다. 따라서 본 연구에서는 부분구조체 실험을 통하여 국내 벽식구조의 연결부재, 즉 슬래브 및 연결보의 거동을 조사하고, 보강에 따른 효과를 검토하고자 하였다. 실험결과 1) 연결슬래브의 응력은 전폭에 걸쳐서 균일하지 않았고, 2) 벽체와 커플링 작용을 하는 연결슬래브의 유효 폭은 기존의 연구에서 제안한 값과 비교하여 큰 차이가 있는 것으로 나타났으며, 국내의 아파트구조에 적용하기에는 과대평가하는 경향이 있었다. 3) 또한 연결 보에서의 X자형 보강은 에너지소산 및 연성비 증가효과가 있는 것으로 나타났으며, 펀칭현상을 개선하여 안정된 이력거동을 확보하는데 효과적인 것으로 나타났다.