• Title/Summary/Keyword: counter-rotation

Search Result 60, Processing Time 0.029 seconds

Tourmaline Crystal Growth by FZ Method (FZ법에 의한 Tourmaline 단결정 성장)

  • 강승민;신재혁;한종원;최종건;오근호;박한수;문종수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 1993
  • Na-Fe Tourmalene ($NaFe_3Al_6B_3Si_6O_{27}F_4$)single crystals were grown by FZ method. The Growth conditions are counter rotation 20~30rpm, growth rate 1~5mm/hr in the atmospheric environment. The transition elements as Fe(in this research), Mn, Co, etc, are exist in the theoretical fomulae so that dopants were not added. The feed rod was sintered between $1000^{\circ}C$ and $1l00^{\circ}C$, but at higher temperature, it was difficult to manufacture the feed rod because of evaporation of the elements such as F. As grown crystals had a black color and the length of 50~60mm, the diameter of 5~6mm. X-ray powder diffraction pattern indicated that the composition of the feed rod was right to the Tourmaline composition. By FT-IR spectra, the state of bonding of each element was charaterized.

  • PDF

YIG(Yttrium Iron Garnet) SingLe Crystal Growth by Floating Zone Method (Floating Zone법에 의한 YIG단결정 성장)

  • 신재혁;김범석;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.2 no.2
    • /
    • pp.1-1
    • /
    • 1992
  • YIG(Yttrium Iron Garnet) single crystals were grown by FZ(Floating Zone) method. Since YIG melts incongruently, TSFZ(Traveling Solvent Floating Zone) method which was modified FZ was applied to grow YIG single crystals. The optimum growth condition were growth rate Imm/hr, counter-rotation 30rpm and oxidized atmosphere was necessary to sintering and growth process. The quality of grown crystals depended on the degree of sintering. The voids were generated by the reaction of Fe ions with oxygen and the density of voids was increased with the growth rate increased. When the growth rate was more than 1.5mm/hr, the cellular growth occured and the density of dislocation was increased at the periphery of crystals. Also, secondary phases of orthoferrite(YFe$O_3$)compost ion were observed in the grown crystal.

  • PDF

Experimental Study on Interaction Effect of Darrieus Tidal Stream Turbines (다리우스 조류 터빈의 상호작용 효과에 대한 실험적 연구)

  • Kim, Jihoon;Park, Jin-Soon;Ko, Jin Hwan
    • Ocean and Polar Research
    • /
    • v.41 no.3
    • /
    • pp.193-202
    • /
    • 2019
  • There have been various approaches for efficiency improvement of a Darrieus tidal stream turbine after it was introduced as an alternative of horizontal axis turbines. Among the approaches, the researches on the interaction effect of dual configuration were conducted. In this study, a dual Darrieus turbine with a coupling mechanism was proposed for investigating the interaction effect. Also, the effect of bi-directional tidal stream was analyzed with prototype fabrication, apparatus set-up and experiment conduction in indoor and offshore facilities. As the results of the experiments, the dual turbine in case of counter-rotation and inflow between the turbines improved efficiencies by 9.5% and 11.31%, respectively, as compared to the single turbine. Also, the dual turbine in case of the inflow improved efficiencies by 9.4% and 16.62%, respectively, as compared to that in case of outflow between the turbines which represented the case of 180 degrees change of flow direction after slack water. Therefore, the proposed dual turbine showed the advantage in terms of the efficiency as compared to the single turbine and the effect level of the slack water on the performance of the dual turbine was investigated.

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Analysis on Forces Acting on the Contact Lens Fitted on the Cornea (콘택트 렌즈에 작용하는 힘의 해석)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.1-11
    • /
    • 2002
  • A mathematical model is proposed to analyze the force; acting on the hard contact lens fitted on the cornea. The model incorporates the nonlinear equations and their numerical solution program, based on the formulations of surface tension force arising from the capillary action in the tear-film layer between the lens and cornea. The model simulates how the adhesion between lens and cornea varies according to the base curves and diameters of the lenses. When the spherical lens is fitted on the spherical cornea it is to rotate downward due to the weight of lens itself until it reaches an equilibrium position along the cornea where the counter(upward) moment caused by net force between the upper and lower portion of the periphery of lens. It is found that both the adhesion and displacement of lens along the cornea, where the gravity of lens balances the capillary-induced upward force, increases rapidly as the base curve of lens increases, i.e., as the lens gets flatter, while the increase in the diameter of lenses has resulted in the less increase in the rotation and adhesion. With the base curve and diameters of lenses being remained constant the increase in surface tension of tear film yields the increase in the adhesion between the cornea and lens while the initial rotation of lens is inversely proportional to the surface tension of the tear film.

  • PDF

Influence of Processing on Morphology, Electrical Conductivity and Flexural Properties of Exfoliated Graphite Nanoplatelets-Polyamide Nanocomposites

  • Liu, Wanjun;Do, In-Hwan;Fukushima, Hiroyuki;Drzal, Lawrence T.
    • Carbon letters
    • /
    • v.11 no.4
    • /
    • pp.279-284
    • /
    • 2010
  • Graphene is one of the most promising materials for many applications. It can be used in a variety of applications not only as a reinforcement material for polymer to obtain a combination of desirable mechanical, electrical, thermal, and barrier properties in the resulting nanocomposite but also as a component in energy storage, fuel cells, solar cells, sensors, and batteries. Recent research at Michigan State University has shown that it is possible to exfoliate natural graphite into graphite nanoplatelets composed entirely of stacks of graphene. The size of the platelets can be controlled from less than 10 nm in thickness and diameters of any size from sub-micron to 15 microns or greater. In this study we have investigated the influence of melt compounding processing on the physical properties of a polyamide 6 (PA6) nanocomposite reinforced with exfoliated graphite nanoplatelets (xGnP). The morphology, electrical conductivity, and mechanical properties of xGnP-PA6 nanocomposite were characterized with electrical microscopy, X-ray diffraction, AC impedance, and mechanical properties. It was found that counter rotation (CNR) twins crew processed xGnP/PA6 nanocomposite had similar mechanical properties with co-rotation (CoR) twin screw processed or with CoR conducted with a screw design modified for nanoparticles (MCoR). Microscopy showed that the CNR processed nanocomposite had better xGnP dispersion than the (CoR) twin screw processed and modified screw (MCoR) processed ones. It was also found that the CNR processed nanocomposite at a given xGnP content showed the lowest graphite X-ray diffraction peak at $26.5^{\circ}$ indicating better xGnP dispersion in the nanocomposite. In addition, it was also found that the electrical conductivity of the CNR processed 12 wt.% xGnP-PA6 nanocomposite is more than ten times higher than the CoR and MCoR processed ones. These results indicate that better dispersion of an xGnP-PA6 nanocomposite is attainable in CNR twins crew processing than conventional CoR processing.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

A STUDY ON POSITIONAL CHANCE OF THE HYOID BONE BEFORE AND AFTER ACTIVATOR THERAPY IN ANGLE'S CLASS III MALOCCLUSION PATIENTS (Angle씨 III급 부정교합 환자중 Activator사용 전후의 설골의 위치 변화에 관한 연구)

  • Koh, Sang-Duk;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.827-839
    • /
    • 1994
  • This study was conducted to assess the positional changes of hyoid bone following the use of activator in Angles class III malocclusion patients with functional factors. For this study, 40 Angle's class I patients and 40 Angle's class III patients, totally 80 subjects were used. They are all in Hellman's dental age IIIB-IIIC ranges. In lateral cephalogram to compare Angle's class I group and Angle's class III group, and the positional changes of the hyoid bone before and after the use of activator in Angle's class III malocclusion group. The results were obtained as follows; 1. Comparison of Angle's class I group and Angle's class III group. In comparison to Angle's class I group, hyoid bone is more anteriorly and superiorly positioned in Angle's class III group. The hyoid bone showed reverse inclination to the mandibular plane in Angle's class III malocclusion group. 2. Comparison of the hyoid positional change before and after use of Activator in Angle's class III malocclusion group. The hyoid bone is displaced posteriorly and inferiorly in vertical relationship. The hyoid bone also showed counter-clockwise rotation. 3. No statistical difference was found between after Activator use data of Angle's class m malocclusion group and Angle's class I group. It is concluded that the hyoid bone in Angle's class III malocclusion group changed its position, similar to Angle's class I malocclusion group.

  • PDF

A Study on the change of shape of the flume cross section for the control of bottom shear stress distribution of an annular flume (환형수조의 바닥전단응력 균일화를 위한 수조단면의 형상변화에 대한 연구)

  • Yang, Su-Hyun;Im, Ik-Tae;Hwang, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.177-177
    • /
    • 2011
  • 환형수조는 점착성 퇴적물의 침/퇴적실험을 위한 실험장치로서, 수조내부의 수면과 접하여 회전하는 상부링(top ring)의 마찰력에 의해 흐름이 생성되며, 시간의 제약없이 흐름조건을 동일하게 만들 수 있다는 큰 장점을 갖는다. 그러나 환형수조는 원주유속의 속도차이 및 원심력으로 인한 2차 순환류가 형성되어 바닥전단응력이 불균일해지는 단점을 가지고 있으며, 이러한 이유로 인하여 환형수조를 이용한 침/퇴적실험 수행시 수조의 외벽부근에서 더 큰 침식이 발생한다. 따라서, 2차 순환류의 발생을 줄이고 바닥전단응력의 분포를 균등하게 하기 위해 양방향 회전(환형수조의 몸체를 상부링의 회전방향과 반대방향으로 회전)이 가능한 환형수조가 고안되었는데, 이러한 방법으로 2차 순환류의 크기를 저감시키고, 바닥전단응력을 균일하게 만들 수 있다. 한편, 환형수조의 양방향 회전(counter-rotation)은 현장용 환형수조에는 적용될 수 없는 단점을 갖는다. 현장실험에서는 바닥면이 없는 현장용 환형수조를 해저면에 거치시켜 자연상태의 비교란 퇴적물 시료를 저면으로 형성시키는데, 바닥면이 존재하지 않는 환형수조 본체는 회전시킬 수 없으므로 양방향 회전을 통한 2차 순환류의 저감 및 바닥전단응력 균일화의 효과를 기대할 수 없다. 이러한 이유로 환형수조의 양방향 회전은 단지 실내실험용 환형수조에만 적용된다. 이에 본 연구에서는 환형수조 본체를 회전시키지 않고 수조의 측벽과 상부링의 각도 조절을 통해 수조단면의 형상을 변화시켜 2차 순환류를 저감시키고 바닥전단응력을 균등하게 하는 방법에 대한 연구가 수행되었다. 이 방법은 본체의 회전이 필요 없으므로 현장용 환형수조에 적용될 수 있을 뿐만 아니라, 실험장치의 구조가 단순해져 실험장치의 제작비가 절감될 수 있다. 또한 원주속도에 수직한 단면에서 속도구배가 감소되어 2차 순환류가 저감됨과 동시에 바닥전단응력이 균등하게 됨으로서 양방향 회전시와 동일한 효과가 얻어질 수 있을 것으로 예상된다.

  • PDF

A Study on the estimation of the flow characteristics and the bottom shear stress in an annular flume (환형수조의 내부 흐름특성 및 바닥전단응력 산정에 대한 연구)

  • Yang, Su-Hyun;Im, Ik-Tae;Hwang, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.176-176
    • /
    • 2011
  • 환형수조는 점착성 퇴적물의 이송특성 연구를 위해 가장 선호되는 실험 장치로 알려져 있다. 과거 많은 연구자들은 퇴적물의 이송특성, 특히 침식/퇴적 특성 조사를 위해 주로 수로를 이용한 실험적 연구를 수행하였는데, 최초의 실험적 연구들은 주로 직선수조에서 수행되었다. 그러나 입자간의 응집이 중요한 역할을 하는 점착성 퇴적물의 경우에, 직선수조 끝단에서의 자유낙하 및 재순환 펌프의 날개에 의해 응집된 토사가 쉽게 분리될 수 있어 그 타당성이 의문시 되어 왔으며, 이러한 단점을 보완하기 위해 환형수조가 고안되었다. 환형수조는 수면과 접하여 회전하는 상부링의 마찰력에 의해 흐름이 생성되기 때문에 시간의 제약 없이 흐름조건을 동일하게 만들 수 있다는 큰 장점을 갖는다. 그러나 환형수조는 원주유속의 속도차이 및 원심력으로 인한 2차 순환류를 형성시켜 반경 방향(radial direction)에서의 바닥전단응력을 불균일하게 하는 단점을 갖는다. 이러한 2차 순환류와 바닥전단응력의 불균일을 저감시키기 위하여 환형수조의 몸체를 상부링의 회전 방향과 역방향으로 직접 회전시키는 방법이 채택되어져 왔다. 한편, 환형수조의 상부링과 몸체를 서로 역방향으로 동시에 회전시키는 양방향 회전(counter-rotation)의 적용을 위해서는 2차 순환류가 최소가 되며 바닥전단응력이 균일해지는 최적 회전속도비에 대한 분석은 필수적 사항이다. 이를 위하여, 상부링과 몸체의 회전속도에 따라 변화하는 수조내부의 흐름특성 및 평균바닥전단응력에 대한 연구가 선행되어야만 한다. 이에 본 연구에서는 전산유체역학을 이용하여 전북대에 설치된 환형수조의 상부링과 몸체의 회전속도에 따라 변화하는 수조내부에서의 흐름특성 및 바닥전단응력에 대한 분석이 수행되었다. 또한, 이를 기초로, 환형수조의 최적 회전속도비 산출을 위한 연구가 수행 중에 있다. 이러한 결과들은 추후 환형수조를 이용한 점착성 퇴적물의 침식/퇴적 등과 같은 이송특성 연구시, 퇴적물에 작용하는 흐름조건의 정밀산정을 위한 기초자료로 활용될 수 있을 것이다.

  • PDF