• 제목/요약/키워드: corrosion behaviors

검색결과 266건 처리시간 0.027초

Effect of Hydrodynamic Condition on the Electrochemical Behavior of Various Metals in 3.5 wt% NaCl Solution

  • Pan, Szu-Jung;Hadinata, Samuel-Sudibyo;Kao, Ruey-Chy;Tsai, Wen-Ta
    • Corrosion Science and Technology
    • /
    • 제14권5호
    • /
    • pp.218-225
    • /
    • 2015
  • The electrochemical behaviors of various metals with and without diamond-like-carbon (DLC) coating in 3.5 wt% NaCl solution were investigated. The effect of hydrodynamic conditions was focused by employing a rotating disc electrode (RDE). The experimental results showed that each bare metal had a more positive corrosion potential and a higher corrosion rate due to enhanced oxygen transport at the higher rotating speed of the RDE. DLC coating caused a substantial increase in the corrosion resistance of all metals studied. However, localized corrosion was still found in the DLC-coated metal at sites where deposition defects existed. Surface morphology examination was performed after the electrochemical test to confirm the roles of hydrodynamic conditions and DLC coating.

천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구 (A Study on Stress Corrosion Behaviors in Welded Zone of the API 5L-X65 Steel for Natural Gas Transmission)

  • 조상근;송한섭;공유식;김영대
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.401-407
    • /
    • 2004
  • This study is on the constant-current stress corrosion test related to the load stress in welded zone and non-welded zone of high tensile strength steel for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed global corrosion and narrow pitting, and the pitting was increased by increasing the load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel for natural gas transmission specimens was decreased suddenly, and the average relative electrode potential was higher and the average relative current was lower in welded zone than base metal. and the average relative electrode potential was decreased by increasing the load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone than base metal, and the corrosion rate was decreased by increasing the load stress.

  • PDF

탄소강 볼트 체결된 GECM(Graphite Epoxy Composite Material)/Al 판재 간의 갈바닉 부식 거동 (Galvanic Corrosion Behavior between Carbon Steel Bolted GECM(Graphite Epoxy Composite Material)/Al plates)

  • 김영식;박수진;유영란
    • Corrosion Science and Technology
    • /
    • 제12권1호
    • /
    • pp.12-26
    • /
    • 2013
  • This work focused on galvanic corrosion of carbon steel bolted GECM/Al plates by long-term test in tap water and NaCl solutions. Test product was carbon steel bolted between cross packed GECM and painted aluminium. Tests for the product and coupled parts determined corrosion rate in tap water and NaCl solutions. Also, using a potentiostat and salt water sprayer, galvanic test was done. In galvanic test on carbon steel bolted GECM/Al plates, corrosion of carbon steel bolt was faster in series of tap water>1% NaCl solution>3.5% NaCl solution. In galvanic couple between aluminium and carbon steel bolt, their corrosion rates were higher than those of single specimen. In galvanic couple between GECM, aluminium, and carbon steel bolt, corrosion behaviors of carbon steel bolt and aluminium were changed due to different corrosion mechanism in tap water and chloride solution.

환경에 따른 구조용 강의 열화거동 분석 (Analysis of Degradation Behavior of Structural Steels Depending on Environment)

  • 이창순;박인규;김용기;장세기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.171-176
    • /
    • 2004
  • Electro chemical corrosion tests were conducted on two structural steels, SS400 and SM490A, in various solutions with different pH values, All materials showed typical active corrosion behaviors in the solutions, and corrosion potential and current density were measured from the slopes obtained from the Tafel curves using linear polarization method. Corrosion potential increased in the acidic region and then decreased depending on the pH values of the solutions. All materials showed the fast corrosion rate in artificial acid rain(pH=4.7), but the slower corrosion rate was observed in NaOH solution(pH=12.0) for SS400 and in distilled water(pH=7.0) for SM490A, respectively, which is thought to come from the difference in chemical composition of two alloys. Generally homogeneous corrosion occurred in acid rain condition, and almost no corrosion was observed in distilled water in both alloys. NaOH solution produced more corrosion than distilled water, and more corrosion had progressed in SS400 than in SM490A in $3.5\%$ NaCl solution.

  • PDF

냉난방용 배관 용접부의 전기화학적 부식특성에 관한 연구 (A Study on Characteristics of the Electrochemical Corrosion of Weld Zone for Refrigerating and Heating Systems Pipe)

  • 임우조;윤병두;김환식
    • 수산해양교육연구
    • /
    • 제19권1호
    • /
    • pp.84-90
    • /
    • 2007
  • This paper was studied on the electrochemical corrosion characteristics of weld zone for refrigerating and heating systems pipe. Austenitic stainless steel is widely applied to various fields of industry, because it is good to corrosion resistance and mechanical properties. But STS 304 is reliable to sensitization by heat cycle on welding. Therefore, in this study, electrochemical polarization test of STS 304 steel pipe manufactured by arc welding in tap water was carried out. And then polarization resistance behavior, uniform and local corrosion behaviors of base metal(BM), weld metal(WM) and heat affected zone(HAZ) for STS 304 pipe were investigated. The corrosion current density of STS 304 steel pipe is high in order of BM(153nA/cm2) < WM(614nA/cm2) < HAZ ($1.675{\mu}A/cm2$). The pitting potential of HAZ(238mV/SCE) for STS 304 is lower than BM(1206mV/SCE) and WM(369mV/SCE). Therefore, the local corrosion like pitting corrosion, galvanic corrosion and crevice corrosion of HAZ for STS 304 is more sensitive than BM and WM.

슈퍼오스테나이트 스테인리스강의 순환동전위 분극특성에 미치는 해수온도의 영향과 손상 거동에 관한 미시적 분석 (Effect of Seawater Temperature on the Cyclic Potentiodynamic Polarization Characteristics and Microscopic Analysis on Damage Behavior of Super Austenitic Stainless Steel)

  • 황현규;김성종
    • Corrosion Science and Technology
    • /
    • 제20권6호
    • /
    • pp.412-425
    • /
    • 2021
  • Because austenitic stainless steel causes localized corrosion such as pitting and crevice corrosion in environments containing chlorine, corrosion resistance is improved by surface treatment or changes of the alloy element content. Accordingly, research using cyclic potentiodynamic polarization experiment to evaluate the properties of the passivation film of super austenitic stainless steel that improved corrosion resistance is being actively conducted. In this investigation, the electrochemical properties of austenitic stainless steel and super austenitic stainless steel were compared and analyzed through cyclic potentiodynamic polarization experiment with varying temperatures. Repassivation properties were not observed in austenitic stainless steels at all temperature conditions, but super austenitic stainless steels exhibited repassivation behaviors at all temperatures. This is expressed as α values using a relational formula comparing the localized corrosion rate and general corrosion rate. As the α values of UNS S31603 decreased with temperature, the tendency of general corrosion was expected to be higher, and the α value of UNS N08367 increased with increasing temperatures, so it is considered that the tendency of localized corrosion was dominant.

세라믹스 몰탈내의 철근 부식 메카니즘 (Corrosion Mechanism of Reinforcing Steel in Ceramic Mortar)

  • 김영만;이강봉;조원일;고재식;최범석;이지영;김영상
    • 분석과학
    • /
    • 제14권4호
    • /
    • pp.364-370
    • /
    • 2001
  • 염분을 함유한 몰탈 환경하에서 기존의 시멘트 몰탈을 대체할 수 있는 석고계 세라믹 몰탈 내의 철근의 부식 현상을 자연전위법, EPMA 분석, 외관조사, 무게 손실정도, 용출 실험에 의해 고찰하였다. 부식 가속화 장치를 이용하여 단기간 내에 부식 현상을 예측하였으며, 관찰된 외관 모습과 무게 손실정도를 통하여 부식 유무를 판단할 수 있었고, 실제 공시체 시료의 용출 실험을 통해 pH의 영향보다는 부식 메카니즘에 ${SO_4}^{2-}$의 영향이 크다는 것을 알 수 있었다.

  • PDF

Corrosion and Nanomechanical Behaviors of 16.3Cr-0.22N-0.43C-1.73Mo Martensitic Stainless Steel

  • Ghosh, Rahul;Krishna, S. Chenna;Venugopal, A.;Narayanan, P. Ramesh;Jha, Abhay K.;Ramkumar, P.;Venkitakrishnan, P.V.
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.281-289
    • /
    • 2016
  • The effect of nitrogen on the electrochemical corrosion and nanomechanical behaviors of martensitic stainless steel was examined using potentiodynamic polarization and nanoindentation test methods. The results indicate that partial replacement of carbon with nitrogen effectively improved the passivation and pitting corrosion resistance of conventional high-carbon and high- chromium martensitic steels. Post-test observation of the samples after a potentiodynamic test revealed a severe pitting attacks in conventional martensitic steel compared with nitrogen- containing martensitic stainless steel. This was shown to be due to (i) microstructural refinement results in retaining a high-chromium content in the matrix, and (ii) the presence of reversed austenite formed during the tempering process. Since nitrogen addition also resulted in the formation of a $Cr_2N$ phase as a process of secondary hardening, the hardness of the nitrogen- containing steel is slightly higher than the conventional martensitic stainless steel under tempered conditions, even though the carbon content is lowered. The added nitrogen also improved the wear resistance of the steel as the critical load (Lc2) is less, along with a lower scratch friction coefficient (SFC) when compared to conventional martensitic stainless steel such as AISI 440C.

슈퍼 듀플렉스 스테인리스강(UNS S32506) 레이저 조관용접 튜브의 용접 후 열처리에 따른 부식거동 (Corrosion Behaviors of Laser-welded Super Duplex Stainless Steel(UNS S32506) Tube with Post-Weld Heat Treatment Conditions)

  • 조동민;박진성;홍승갑;황중기;김성진
    • 한국표면공학회지
    • /
    • 제54권3호
    • /
    • pp.102-111
    • /
    • 2021
  • The corrosion behaviors of laser-welded super duplex stainless steel tubes with post-weld heat treatment(PWHT) conditions(950, 1000, 1050, 1100 ℃ for 5 and 30 min) were evaluated by electrochemical potentiodynamic polarization and critical pitting temperature measurements. This study showed that the critical metallurgical factors affecting the degradation of corrosion resistance of a steel tube in as-welded condition were the unbalanced phase fraction(ferrite:austenite = 94:4), Cr2N precipitation, and phase transformation from the austenite phase to ɛ-martensite(via stress-induced phase transformation). The improvement in the corrosion resistance of the welded specimen depends greatly on the PWHT conditions. The specimens after PWHT conducted below 1000 ℃ showed inferior corrosion resistance, caused by precipitation of the sigma phase enriched with Cr and Mo. At 1100 ℃ for a longer duration in PWHT, the ferrite phase grows, and its fraction increases, leading to an unbalanced phase fraction in the microstructure. As a result, pitting can be initiated primarily at the interface between the ferrite/austenite phase, particularly in base metal.

Corrosion Behavior of Zn and Zn-AI Alloy Coated Steels under Cyclic Wet-dry Environments

  • Nishikata, Atsushi;Yadav, Amar Prasad;Tsutsumi, Yusuke;Tsuru, Tooru
    • Corrosion Science and Technology
    • /
    • 제2권4호
    • /
    • pp.165-170
    • /
    • 2003
  • Atmospheric corrosion behaviors of Zn, Zn-5%Al and Zn-55%A l coated steels have been investigated under cyclic wet-dry environments containing chloride ions. The wet-dry cycle was carried out by alternate exposure to immersion in 0.5 M (or 0.05 M) NaCl solutions and drying at $25^{\circ}C$ and 60 %RH. The polarization resistance $R_p$ and solution resistance $R_s$ were monitored by AC impedance technique. From the obtained $1/R_p$ and $1/R_s$ values, the corrosion rate of the coatings and the Time of Wetness (TOW) were estimated, respectively. Effects of chloride ions and TOW on the corrosion rates of Zn, Zn-5%Al, Zn-55%Al coatings and appearance of red rust (onset of underlying steel corrosion) under wet-dry cycles are discussed on the basis of the corrosion monitoring data.