• 제목/요약/키워드: correlation measurement

검색결과 3,259건 처리시간 0.031초

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 이연수;장서일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

The Comparison Between Blind and Normal Children in Standing Position (시각장애 아동과 정상 아동의 선자세 균형 비교)

  • Kim Chung-sun;Lee Jeong-soon
    • The Journal of Korean Physical Therapy
    • /
    • 제15권1호
    • /
    • pp.119-154
    • /
    • 2003
  • In this paper, the proprioceptive sensitivity was compared by Foot-Hand task method and the effect of the proprioceptive sensitivity and auditory to the standing position between blind and normal children was measured using BPM for 56 children in 7, 8, 9 and 10 years old. There are three measurement methods are used for BPM : Rest, Forward Looking, 'Sound' position. The following conclusions were obtained from the above measurements. 1. In comparison of proprioceptive sensitivity between blind and normal children, there is no significant difference(p > .05). There is no significant difference in comparison of each age group and also there is no difference in each gender group(p > .05). 2. In comparison of standing position measurement between blind and normal children, there is any difference (p > .05) in three measurement(Rest, Forward Looking, 'Sound' position) but there is no significant difference in each gender difference(p > .05). There is any difference between Rest and 'Sound' position of blind children, also there is any difference between Forward Looking and ' Sound ' position, rest and 'Sound' position of normal children(p > .05). 3. There is no significant difference of correlation between proprioceptive sensitivity test and standing position measurement in Pearson correlation coefficient(p > .05).

  • PDF

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 장서일;이연수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제14권7호
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

Development of a High Resolution Cinematic Particle Image Velocimetry and Its Application to measurement of Unsteady Complex Turbulent Flows (고분해능 Cinematic PIV 시스템의 개발과 비정상 복잡 난류유동측정에의 응용)

  • Kim, Kyung-Chun;Park, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.536-541
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector for a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. The correct velocity vector at the first step is found to be critical, so we apply a Multiple Correlation Validation(MCV) technique in order to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds the performance of the conventional high resolution digital PIV system using a $1K{\times}1K$ CCD camera.

  • PDF

The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient (엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구)

  • Park, Sun-Wook;Kim, Myoung-Soo;Bae, Hyo-Sun;Cha, Yong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

A Comparative Study on Measurement of Physical Activity between Smartphone App and Self-Reported Questionnaire (스마트폰 앱과 자가보고식 설문지의 신체활동 측정 비교)

  • Suh, Minhee;Seo, Kyoungsan
    • Journal of muscle and joint health
    • /
    • 제29권2호
    • /
    • pp.91-99
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the level of agreement between smartphone apps and self-reported physical activity questionnaires. Methods: Quantitative methods were used to assess the correlation and agreement between the number of steps counted by a smartphone app and the amount of walking reported in a survey. A total of 29 adults who used smartphones were recruited from a university, and their step counts from their smartphone pedometers and responses to the international physical activity questionnaire (IPAQ) were collected over a 10-week period. Results: An analysis of 170 data pairs with Spearman's rho correlation and a Bland-Altman plot revealed a positive correlation between step counts from the smartphone app and walking activity from the IPAQ. The Bland-Altman plot also demonstrated the agreement to be improved among female participants. Conclusion: In assessing walking activity, smartphone pedometer apps showed good correlation with the IPAQ and improved agreement with the IPAQ among women. Therefore, it is suggested that the participants' gender and activity intensity, as well as the accuracy of measurement tools, should be considered in an evaluation of the delivery of physical activity promotion programs through smartphone apps.

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • 제6권1호
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

Selection Criteria of Measurement Locations for Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program (APR1400 원자로내부구조물 종합진동평가 측정위치 선정 기준)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제21권8호
    • /
    • pp.708-713
    • /
    • 2011
  • U.S. nuclear regulatory commission(NRC) regulatory guide(RG) 1.20 requires a comprehensive vibration assessment program(CVAP) for use in verifying the structural integrity of reactor vessel internals(RVI) for flow-induced vibrations prior to commercial operation. The CVAP program consist of vibration and fatigue analysis, a vibration measurement program, an inspection program, and a correlation of their results. One of the main purposes of the analysis program is to select measurement locations, however measurement locations can not be determined by only analysis results, therefore we developed selection criteria of measurement locations for advanced power reactor 1400(APR1400) RVI CVAP, It will be used to select measurement locations and instrument types for APR1400 RVI CVAP.

A Study on Factors and Measurement Methodology on Workers' Work Competence Levels for Sustainable Management in ICT Organization (ICT조직의 지속가능경영을 위한 직무전문성 측정요인과 방법)

  • Yoon, Jang Ho;Kim, Kui Won;Lee, Soo Hyun;Kim, Jae Yun
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • 제10권5호
    • /
    • pp.27-43
    • /
    • 2015
  • Ever more so than any other times, today's corporations today face an ultimate issue of acquiring highest work expertise for their employees. However, most of current academic researches try to focus on what factors comprise an expertise while they fail to tackle the very issue of detailed numerical measurement of the expertise factors recommended improvement paths, and goals for each measured expertise level. Hence, this study suggests more objective and highly reliable identification of work competence measurement factors and the correlation among the identified factors. For details, it tries to propose a methodology of expertise measurement by developing into the definition of experts and expertise, reestablishment of expertise factors, determination of reference points of the expertise factors, and weighting of the factors. This measurement methodology finds that it itself has significant correlation with existing work competency level measurement and test tools. Therefore it is identified to justify its effectiveness. Finally, this study proposes an action point of establishing a national expertise architecture and its frameworks for various societies in general.

  • PDF

A Study of Measurement on Range of Arm Joint Motion of Korean Male in Twenties (한국인 20대 청년의 팔 관절 동작범위 측정 연구)

  • 이영신;이석기;박세진;김철중
    • Proceedings of the ESK Conference
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.62-71
    • /
    • 1995
  • This paper measured the range of arm joint motion for Korean 54 male in twenties. The subjects are measured directly using Goniometer and angle gauge. The static measurement variables are seven and the dynamic measurement variables are thirteen. The anthropometric datum are analyzed by basic statistical analysis, correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach, 1978.

  • PDF