• Title/Summary/Keyword: correction parameter

Search Result 299, Processing Time 0.023 seconds

Ionospheric peak parameter foF2 and its variation trend observed by GPS

  • Jin, Shuanggen;Park, Jong-Uk;Park, Pil-Ho;Choi, Byung-Kyu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.181-184
    • /
    • 2006
  • Knowledge of the ionospheric peak parameter foF2 (the critical frequency of F2 layer) is one of key essential factors for predicting ionospheric characteristics and delay correction of satellite positioning. However, the foF2 was almost estimated using an empirical model of International Reference Ionosphere (IRI) or other expensive observing techniques, such as ionosondes and scatter radar. In this paper, the ionospheric peak parameter foF2 is the first observed by ground-based GPS with all weather, low-cost and near real time properties. Compared with the IRI-2001 and independent ionosondes at or near the GPS receiver stations, the foF2 obtained from ground-based GPS is in better agreement, but closer to the ionosonde. However, during nighttime, the IRI model overestimated the GPS observed values during winter and equinox months.Furthermore, seasonal variation trend of the foF2 in 2003 is studied using foF2 monthly median hourly data measured over South Korea. It has shown that the systematic diurnal changes of foF2 are apparent in each season and the higher values of foF2 are observed during the equinoxes (semiannual anomaly) as well as in mid-daytime of each season.

  • PDF

A simple quasi-3D HDST for dynamic behavior of advanced composite plates with the effect of variables elastic foundations

  • Nebab, Mokhtar;Benguediab, Soumia;Atmane, Hassen Ait;Bernard, Fabrice
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.415-431
    • /
    • 2020
  • In this study, dynamics responses of advanced composite plates resting variable elastic foundations via a quasi-3D theory are developed using an analytical approach. This higher shear deformation theory (HSDT) is included the shear deformation theory and effect stretching that has five unknowns, which is even inferior to normal deformation theories found literature and other theories. The quasi-three-dimensional (quasi-3D) theory accounts for a parabolic distribution of the transverse shear deformation and satisfies the zero traction boundary conditions on the surfaces of the advanced composite plate without needing shear correction factors. The plates assumed to be rest on two-parameter elastic foundations, the Winkler parameter is supposed to be constant but the Pasternak parameter varies along the long side of the plate with three distributions (linear, parabolic and sinusoidal). The material properties of the advanced composite plates gradually vary through the thickness according to two distribution models (power law and Mori-Tanaka). Governing differential equations and associated boundary conditions for dynamics responses of the advanced composite plates are derived using the Hamilton principle and are solved by using an analytical solution of Navier's technique. The present results and validations of our modal with literature are presented that permitted to demonstrate the accuracy of the present quasi-3D theory to predict the effect of variables elastic foundation on dynamics responses of advanced composite plates.

Bending and buckling analyses of functionally graded material (FGM) size-dependent nanoscale beams including the thickness stretching effect

  • Chaht, Fouzia Larbi;Kaci, Abdelhakim;Houari, Mohammed Sid Ahmed;Tounsi, Abdelouahed;Beg, O. Anwar;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.425-442
    • /
    • 2015
  • This paper addresses theoretically the bending and buckling behaviors of size-dependent nanobeams made of functionally graded materials (FGMs) including the thickness stretching effect. The size-dependent FGM nanobeam is investigated on the basis of the nonlocal continuum model. The nonlocal elastic behavior is described by the differential constitutive model of Eringen, which enables the present model to become effective in the analysis and design of nanostructures. The present model incorporates the length scale parameter (nonlocal parameter) which can capture the small scale effect, and furthermore accounts for both shear deformation and thickness stretching effects by virtue of a sinusoidal variation of all displacements through the thickness without using shear correction factor. The material properties of FGM nanobeams are assumed to vary through the thickness according to a power law. The governing equations and the related boundary conditions are derived using the principal of minimum total potential energy. A Navier-type solution is developed for simply-supported boundary conditions, and exact expressions are proposed for the deflections and the buckling load. The effects of nonlocal parameter, aspect ratio and various material compositions on the static and stability responses of the FGM nanobeam are discussed in detail. The study is relevant to nanotechnology deployment in for example aircraft structures.

Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study (팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가)

  • Bahn, Young-Kag;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.53-59
    • /
    • 2011
  • Purpose: To evaluate the dosimetry and image of very low does CT attenuation correction for phantom using pediatric PET/CT. Materials and methods: three PET / CT scanners (Discovery STe, BiographTruepoint 40, Discovery 600) as a child-size acrylic phantom and ion chamber dosimeter (Unfous Xi CT, Sweden) using a CT image acquisition parameters (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp) by varying the depth dose and evaluate $CTDI_{vol}$ value. And each attenuation corrected PET/CT images used NEMA PET Phantom$^{TM}$ (NU2-1994) was evaluated by SUV. Results: Abdominal diagnosis CT dose in general pediatric (about 10 ages) parameter (100 kVp, 100 mA) than very low dose CT parameter (80 kVp, 10 mA) at the depth dose was reduced approximately 92%, $CTDI_{vol}$ was reduced to about 88%. Each CT attenuation corrected parameters PET images showed no change in the value of SUV. Conclusion: for pediatric patients, PET/CT scan can be obtained with very low dose attenuation correction CT (80 kVp, 10 mA), and such attenuation correction CT dose was reduced 100 fold than diagnosis CT dose. PET / CT scan used very low dose CT attenuation correction in pediatric patients can be helpful in reducing radiation dose.

  • PDF

The Suggestion of the Image Registration Using Terrain Relief Correction Based on RFM (유리함수모델 기반 표고시차보상기법을 사용한 Image Registration 방안 제안)

  • Kim, Hyun-Suk;Kim, Moon-Gyu;Seo, Doo-Chun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.21-30
    • /
    • 2012
  • When two bands have different look angle in a space-borne camera system, the registration between two bands is required. The registration cannot be modeled with constant parameters because of dynamic of platform and parallax effect. The parallax effect is caused by terrain relief, hence it causes local distortion between two bands. Therefore, the terrain relief correction in order to reduce the parallax effect is required for better registration result, especially for high resolution image data. Such terrain relief correction also can be applied to image data acquired from multiple detectors with different look angle within a band, which is a one of commonly used configuration for a wider swath in space-borne camera system, in order to reduce the distortion between detectors. The RFM is a popular abstract model in remote sensing field, which gives us the relationship between the image plane and geodetic coordinate system. Therefore, we propose a terrain relief correction method based on the RFM. The experiment showed very promising result.

Comparison of Proximal Metatarsal Osteotomy and Distal Chevron Osteotomy for Correction of Hallux Valgus (무지외반증 치료에서 근위 중족골 절골술과 원위 갈매기형 절골술의 비교)

  • Cho, Duck-Yun;Lee, Dong-Hoon;Rhee, Seung-Yong;Lee, In-Sung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2008
  • Purpose: The purpose of this study is comparison of radiological and clinical outcomes between proximal metatarsal osteotomy and distal chevron osteotomy for the correction of hallux valgus. Materials and Methods: In this retrospective study, we included subjects who underwent the correction of hallux valgus in our institution between March 2001 and August 2006, with a minimum follow-up of 12 months. The group of proximal metatarsal osteotomy was 23 patients (34 feet); the group of distal chevron osteotomy was 20 patients (26 feet). The group of proximal metatarsal osteotomy was composed of 26 severe cases (76.5%) and 8 moderate cases (23.5%); the group of distal chevron osteotomy was composed of 13 severe cases (50.0%) and 13 moderate cases (50.0%). Results: Compared to preoperative values, the hallux valgus angle, the first-second intermetatarsal angle and the distance of first-fifth metatarsal head were significantly decreased in two groups (p<0.05). In each parameter, the hallux valgus angle was decreased 66.3% (proximal metatarsal osteotomy) versus 49.6% (distal chevron osteotomy), which were significant (p=0.037). The first-second intermetatarsal angle and the distance of first-fifth metatarsal head were not significant. Mayo clinic forefoot scoring system (FFSS) score was significantly improved in two groups (p<0.05). The ratio of improvement was not significant (p=0.762). In severe group, hallux valgus angle and the first-second intermetatarsal angle was significantly decreased in proximal metatarsal osteotomy group compared to distal chevron osteotomy group (p<0.05), but the difference of the distance of first-fifth metatarsal head and FFSS score was not significant in both groups. In moderate group, the difference of all parameters was not significant in both groups. Conclusion: Although both proximal metatarsal osteotomy and distal chevron osteotomy showed satisfactory result in FFSS, proximal metatarsal osteotomy was more proper operative technique than distal chevron osteotomy in severe group, because of superiority of correction in radiological parameters.

  • PDF

A study of sea level measurement using GPS buoy (GPS 부의를 이용한 해수면 관측에 관한 연구)

  • Park, Un-Yong;Oh, Chang-Soo;Lee, Dong-Rak;Hong, Jung-Soo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.85-88
    • /
    • 2007
  • Sea level fluctuation present a direct influence to those who live near the coast. The importance of monitoring sea level is evident. Therefore, various techniques have been employed for sea level measurements such as the coastal water level gauges, satellite altimetry and GPS buoy. Especially, GPS buoys have been used to measure water levels, atmospheric parameter and other physical conditions in sea, tide correction, the altimeter range calibration, ocean environment. In this paper, we will mainly concentrate on the kinematic technique for GPS buoy to measure the sea level. A test was carried out to test the method proposed in this paper, which made use of a GPS buoy equipped to monitor the sea level in Busan. We have executed to analysis about applications of GPS buoy.

  • PDF

Accuracy Improvement of Precipitable Water Vapor Estimation by Precise GPS Analysis (GPS 관측데이터 정밀 해석을 통한 가강수량 추정 정확도 향상)

  • Song, Dong-Seob;Yun, Hong-Sic
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.27-30
    • /
    • 2007
  • The objective of this study is to improve an accuracy of PWV estimates using GPS in Korea. We determined a weighted mean temperature equation by a linear regression method based on 6 radiosonde meteorological observations, for a total 17,129 profiles, from 2003 to 2005. Weighted mean temperature, Tm, is a key parameter in the retrieval of atmospheric PWV from ground-based GPS measurements of zenith path delay. The accuracy of the GPS-derived PWV is proportional to the accuracy of Tm. And we applied the reduction of air Pressure to GPS station altitude. The reduction value of air pressure from mean sea level to GPS stations altitude is adopted a reverse sea level correction.

  • PDF

A Prediction Model for Low Cycle Fatigue Life of Pre-strained Fe-18Mn TWIP Steel (Fe-18Mn TWIP강의 Pre-strain에 따른 저주기 피로 수명 예측 모델 연구)

  • Kim, T.W.;Lee, C.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • The influence of pre-strain in low-cycle fatigue behavior of Fe-18Mn-0.05Al-0.6C TWIP steel was studied by conducting axial strain-controlled tests. As-received plates were deformed by rolling with reduction ratios of 10 and 30%, respectively. A triangular waveform with a constant frequency of 1 Hz was employed for low cycle fatigue test at the strain amplitudes in the range of ${\pm}0.4{\sim}{\pm}0.6$ pct. The results showed that low-cycle fatigue life was strongly dependent on the amount of pre-strain as well as the strain amplitude. Increasing the amount of prestrain, the number of reversals to failure was significantly decreased at high strain amplitudes, but the effect was negilgible at low strain amplitudes. A new model for predicting fatigue life of pre-strained body has been devised adding a correction term of ${\Delta}E_{pre-strain}$ to the energy-based fatigue damage parameter.

  • PDF

Improved Charge Pump Power Factor Correction Electronic Ballast Based on Class DE Inverter

  • Thongkullaphat, Sarayoot
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.64-70
    • /
    • 2015
  • This paper proposes fluorescent electronic ballast with high power factor and low line input current harmonics. The system performance can be improved by a charged pump circuit. Details of design and circuit operation are described. The proposed electronic ballast is modified from single-stage half bridge class D electronic ballast by adding capacitor parallel with each power switch and setting the circuit parameter to operate under class DE inverter condition. By using this proposed method the DC bus voltage can be reduced around by 50% compare with conventional class D inverter circuit. Because the power switches are operated at zero voltage switching condition and low dv/dt of class DE switching. The experimental results show that the proper frequency of the prototype is around 50 kHz with input power factor of 0.982, $THD_i$ 10.2% at full load and efficiency of more than 90%.