• Title/Summary/Keyword: corrected tomography

Search Result 87, Processing Time 0.027 seconds

Investigation of Concrete Structure Using Geophysical Prospecting Method (물리탐사법을 이용한 콘크리트 구조물 조사에 관한 연구)

  • Suh, Baek-Soo;Kim, Yong-In
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.63-68
    • /
    • 2003
  • Non-destructive method by tomography for safety diagnosis of civil engineering and building structures is tried. There are traveltime tomography that uses traveltime and fullwave tomography that uses the initial shock and seismic amplitude. But these methods have difficulty and weak points in accuracy and selection of initial value. In this study, corrected inversion method which is able to solve the two difficulty and this method is applied to theoretical pier model to calculate tomography.

  • PDF

Condylar position on the lateral individualized corrected tomography in internal derangement of temporomandibular joint (측두하악관절 내장증시 측방 개별화 보정단층방사선사진에서의 하악과두의 위치)

  • Kim Keun-Min;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.67-73
    • /
    • 2002
  • Purpose: To examine the possible relationship between condylar position and disk displacement in the temporomandibular joint. Materials and Methods: 79 temporomandibular joints in 40 patients having temporomandibular disorders were classified into three categories: no disk displacement (NDD) , disk displacement with reduction (DDWR), and disk displacement without reduction (DDWOR). Disk positions were assessed from clinical and MRI findings. The relationship between the three categories and condylar positions was evaluated using lateral individualized corrected tomography. Results: Clinical findings regarding the relationship between condyle and disk positions having anterior, centric, and posterior positions were 27%, 27%, and 46%, respectively, in NDD, 43%, 17%, and 40%, respectively, in DDWR, and 44%, 22%, and 34%, respectively, in DDWOR. There were no significant differences in condylar positions between each of the groups (P>0.05). In the relationship between condyle and disk positions with MRI findings, anterior, centric, and posterior positions were 38%, 38%, and 24%, respectively, in NDD, 29%, 21%, and 50%, respectively, in DDWR, and 44%, 9%, and 47% respectively, in DDWOR. There were significant differences in the condylar positions when MRI was utilized (P<0.05) Conclusion: There was a significant correlation between the condyle and disk positions with MRI findings on lateral individualized corrected tomography.

  • PDF

CHANCE OF CONDYLAR POSITION AFTER ORTHODONTIC TREATMENT OF ANTERIOR OPEN BITE (전치개교의 교정치료와 과두위치 변화)

  • Shin, Soo-Jung;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.587-620
    • /
    • 1994
  • This study was aimed to evaluate the changes in condylar position when severe anterior open bite patients were treated with MEAW. The subjects consisted of 11 patients(21 TMJs) who visited the departement of orthodontics in SNUH, having severe anterior open bite as a chief complain. They were supposed to wear the up and down elastics and MEAW after finishing the leveling. The condylar position was evaluated with individualized corrected tomography in centric occlusion taken before and after treatment. The results were as follows; 1. In the change of condylar position after treatment, there were no statistically significant differences in right and left TMJs. 2. In the change of condylar position after treatment, there were no statistically significant differences in each malocclusion groups. 3. There were no statistically significant differences in percent dispacement of condyle between before and after treatment 4. There were no statistically significant differences in the amount of change in condylar change.

  • PDF

Numerical Experiments for Detecting Voids and Defects Inside Concrete (수치모형실험을 통한 콘크리트 구조물의 결함탐지에 관한 연구)

  • Kim, Yong-In;Byun, Joong-Moo;Sohn, Kwon-Ik;Suh, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.163-170
    • /
    • 2004
  • In this study, First, the results of travel-time inversion (first arrival inversion using the travel-time of the first arrival) were compared with those of full-wave inversion for numerical data. Numerical experiments to find key parameters other than initial velocity model showed that the frequency of source has a great effect on the result of full-wave inversion. Finally, this research presented the corrected full-wave inversion applying the correction term to the final result of full-wave inversion. The corrected full-wave inversion depicted cavities inside concretes even when the inversion started with 20% error in an initial velocity model for cavities. However, full-wave inversion did not reveal cavities.

  • PDF

Treatment planning of Lung Cancer with Density corrected Computed Tomography (밀도를 입력한 CT planning을 이용한 Lung Cancer의 치료계획)

  • 김성규;김명세;신세원;홍정숙
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 1993
  • Treatment planning of lung cancer with density corrected Computed tomography. Eighty-seven patients with lung cnacer who had radiation therapy in Yeungnam University Medical Center between, April 1 1990 and Aug. 30 1993 were retrospectively evaluated total tumor dose, dose distribution, field correction, and loading change, compared with contour or CT image planning and density corrected CT planning. In dose distribution, higher dose was calculated in compare with density corrected CT planning less than 5% difference were found in 45 patient(52%), 5-10% in 25 patients (29%), 10-15% in 15 patients (17%) and over 15% in 2 patients (2%). Correction of treatment field was performed in 18 patients (21%) and changing of dose loading was given in 15 patients (17%). In conclusion, we emphasize that density corrected CT planning is the very important factor which contribute to increase therapeutic gain by exact selection of target volume, target dose, normal tissue dose and dose of critical organ.

  • PDF

The angulation and the position change of the planned implant after tomographic imaging (단층촬영상에서 계획된 임플랜트 매식 각도 및 위치에 대한 스텐트 핀의 상대적 각도 및 위치에 대한 평가)

  • Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.127-131
    • /
    • 2007
  • Purpose: To measure the differences of the splint pin angulation and the position of the planned implant site after conventional tomographic analysis. Materials and Methods: The angulation and the location of the metal splint pin retained in acrylic stent were compared with the corrected angulation and the location of the implant fixture on the 331 tomographic images. Results: The stent pins were located buccal in 40%, lingual in 10% to the corrected implant site after analysis of the conventional tomographic image. The angle and the location of the maxillary splint pin were mainly directed buccal on incisor and canine regions. The angle and the location of the splint pins in premolar and molar regions needed less corrections in both maxilla and mandible. Conclusions: This study demonstrated that the use of tomographs was essential for successful dental implant planning.

  • PDF

Correction of the Refraction Effect on the Real-Time Nonlinear Parameter Tomogram (초음파 비선형 단층영상에 나타나는 굴절의 영향 보정법)

  • 이현주;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.5
    • /
    • pp.335-342
    • /
    • 1991
  • A real-tme nonlinear parameter tomography is pumping wave method. This tomorgraphy has a merit which requires no 180$^{\circ}$ projection datum, while the ray-bending effect is remrkably remained on the reconstructed image. In this paper we intend to compensate this ray-bending effect using the perturbation method. Impulsive pumping wave makes derived compensative term simple form, nad the compensative image is easily obtained. We perform computer simulation to confirm the improvement of corrected imate.

  • PDF

Soot Temperature and Concentration Measurement Using Emission/Transmission Tomography in Laminar Diffusion Flame (방사와 투과를 이용한 층류확산화염내 매연입자의 온도 및 농도 측정)

  • 송상종;박성호;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2563-2573
    • /
    • 1993
  • The measurements of monochromatic line-of-sight flame emission and light transmission in the same path having small spatial resolution were performed in an axisymmetric laminar propane $C_{3}H_{8}$ diffusion flame. The light wavelengthes of 632 nm, 800nm, 900nm were used. From these measurements, local point soot radiances (by Kirchhoff's law) and absorption coefficients were reconstructed by tomography. Thus local point soot temperatures and concentrations were obtained. The reconstructed soot temperatures and concentrations of local points have no differences between the case of visible range (632 nm) and the case of infrared range (800 nm and 900 nm). In these ranges, the scattering coefficient is much lower than the absorption coefficient. Soot mean temperature over the path also matches well with local soot temperature in outer region of the flame. Temperature measurement by thermocouple with different bead diameters $(222{\mu}m and 308{\mu}m)$ was carried in the same flame. Rapid insertion technique was used and radiation effect was considered. Radiation correction in the sooting region was carried out and the corrected result was in good agreement with the local soot temperature.

Comparative study on alveolar bone height of pantomography and multi planar reformatted computed tomography (파노라마방사선사진과 다면상재구성 CT상의 치조골 높이 계측에 대한 비교 연구)

  • Ji Jung-Hyun;Lee Sang-Rae;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.159-164
    • /
    • 2004
  • Purpose: To compare alveolar bony height of pantomograph with bony height of thin slice, multiplanar reformatted (MPR) Computed Tomograph. Materials and Methods : Panoramic radiograms of 12 young adult patients had been taken by one radologic technitian and the measurements were corrected by magnification ratio (1.20). The slice thickness of Multi-detector Computed Tomography (CT) was at least 1mm for the accuracy. The raw CT datas were imported into the V-works 4.0 (CyberMed Corp., Seoul, Korea) and transformed to MPR images. Pantomographic measurements of alveolar bone were compared to CT values by average mean bony height measurements for the accuracy. Inter-, and Intra-observer variability was evaluated. Results : There was no significant differences between height measurement of pantomography and that of CT (P>0.05). There were no significant differences in either inter-or intra-observer measurements (P>0.05). Conclusion : Pantomography showed relatively high accuracy and precision in measuring alveolar bony height.

  • PDF

Surgical Experience of Funnel Chest (누두흉의 임상적 고찰)

  • Ahn, Byoung-Hee;Hur, Sun
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.316-324
    • /
    • 1990
  • This study is a review of the early postoperative results in fifteen patients who diagnosed funnel chest and underwent the corrective surgical procedure by the sternal turnover[STO] or the sternocostal elevation[SCE] between January 1988 and February 1990. Thirteen among fifteen patients were male. Early eight patients were corrected by the STO and late seven patients by the SCE. Cosmetic result was excellent in one, fair in five, poor in two patients who received the STO and excellent in all patients corrected by the SCE. This unfavorable postoperative result in the STO group was due to the protrusion of inverted xiphisternal joint, the depression along the rejoined costal cartilages and forward tilting of the distal sternum. The lower vertebral indices measured on the lateral chest film were improved postoperatively from 0.42\ulcorner0.08 to 0.30\ulcorner0.05 in the STO group and from 0.31\ulcorner0.05 to 0.24\ulcorner0.03 in the SCE group. There was significant improvement in lower vertebral index in both groups, but it was difficult to compare the postoperative improvement between groups due to the different preoperative status. In the SCE group, the funnel index and the degree of depression measured on the computed tomography were significantly improved from 5.29\ulcorner1.72 and 3.11\ulcorner0.71 to 2.77\ulcorner0.46 and 1.63\ulcorner0.19[P<0.05], but there was no significant change in the degree of flatness postoperatively. This results suggest that sternocostal elevation is more cosmetic procedure than sternal turnover in children and in young adolescents whose funnel index measured on the computed tomography is low.

  • PDF