• Title/Summary/Keyword: coronary artery CT angiography

Search Result 51, Processing Time 0.023 seconds

A Case of Aberrant Right Subclavian Artery (Arteria Lusoria) with Chest Tightness and Coughing (요골동맥을 통한 관상동맥촬영 중 진단된 편위된 우측쇄골하동맥 1예)

  • Han, Seung-Hee;Kim, Su-Young;Park, Hye-Kyong;Park, Jong-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.29 no.1
    • /
    • pp.61-64
    • /
    • 2012
  • The left aortic arch with an aberrant right subclavian artery, or arteria lusoria, is the most common aortic arch anomaly, occurring in 0.5-2.5% of individuals. In such cases, the angular course of the arteria lusoria to the ascending aorta imposes difficulty in passing a guide wire to the ascending aorta during right transradial catheterization. Here, the case of a 53-year-old woman with intermittent chest tightness and coughing is reported. Aberrant right subclavian artery (arteria lusoria) was diagnosed via aortogram during right transradial coronary angiography. Compression of the esophagus and trachea by the aberrant right subclavian artery was demonstrated by chest computed tomography (CT).

  • PDF

Coronary CT Angiography with Knowledge-Based Iterative Model Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques

  • Tao Li;Tian Tang;Li Yang;Xinghua Zhang;Xueping Li;Chuncai Luo
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.729-738
    • /
    • 2019
  • Objective: To assess the effects of iterative model reconstruction (IMR) on image quality for demonstrating non-calcific high-risk plaque characteristics of coronary arteries. Materials and Methods: This study included 66 patients (53 men and 13 women; aged 39-76 years; mean age, 55 ± 13 years) having single-vessel disease with predominantly non-calcified plaques evaluated using prospective electrocardiogram-gated 256-slice CT angiography. Paired image sets were created using two types of reconstruction: hybrid iterative reconstruction (HIR) and IMR. Plaque characteristics were compared using the two algorithms. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images and the CNR between the plaque and adjacent adipose tissue were also compared between the two reformatted methods. Results: Seventy-seven predominantly non-calcified plaques were detected. Forty plaques showed napkin-ring sign with the IMR reformatted method, while nineteen plaques demonstrated napkin-ring sign with HIR. There was no statistically significant difference in the presentation of positive remodeling, low attenuation plaque, and spotty calcification between the HIR and IMR reconstructed methods (all p > 0.5); however, there was a statistically significant difference in the ability to discern the napkin-ring sign between the two algorithms (χ2 = 12.12, p < 0.001). The image noise of IMR was lower than that of HIR (10 ± 2 HU versus 12 ± 2 HU; p < 0.01), and the SNR and CNR of the images and the CNR between plaques and surrounding adipose tissues on IMR were better than those on HIR (p < 0.01). Conclusion: IMR can significantly improve image quality compared with HIR for the demonstration of coronary artery and atherosclerotic plaques using a 256-slice CT.

Vascular anatomy and their variations in Situs inversus totalis using postmortem computed tomographic angiography

  • Dawa Zangpo;Hironobu Nakane;Morio Iino
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.155-159
    • /
    • 2023
  • Studies describing the vascular systems and their variations in Situs inversus totalis (SIT) from a whole-body computed tomographic (CT) angiography perspective are lacking. We report a case of SIT in which postmortem CT angiography (PMCTA) was performed as a part of the forensic death investigation and incidentally detected several vascular variations in it. The PMCTA procedure was performed using the multiphase PMCTA protocol. Almost all major vessels were visualized, indeed in a completely reversed pattern. Contrast mixture flow interruptions were noted in the right coronary arterial branches suggesting possible blockage, upon which autopsy revealed >90% vessel occlusions at several locations. As such the cause of death was due to ischemic heart disease. Anomalous origins of the right internal mammary artery; abnormal left thyrocervical trunk and variations in the drainage of testicular veins were noted. Our findings might be helpful to clinicians and add to the body of literature on SIT.

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.

Use of Coronary CT Angiography as a Screening Tool for Coronary Artery Disease in Asymptomatic Healthy Individuals or Patients (무증상 정상인 또는 환자의 관상동맥 질환 선별 검사로서 관상동맥 전산화단층촬영 혈관조영술의 유용성)

  • Gong Yong Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.54-69
    • /
    • 2022
  • Early detection of potential asymptomatic coronary artery disease is very important, as patients with sudden cardiac death often do not show symptoms such as chest pain or motor dyspnea. Coronary CT angiography (CCTA) has long been unjustified as a screening tool for asymptomatic patients because of the risks posed by radiation exposure. However, there are still various opinions regarding the usefulness of CCTA for screening for coronary artery disease (CAD) in asymptomatic healthy individuals or patients. This review investigated the usefulness of coronary artery calcium score and CCTA as screening tests for CAD in asymptomatic healthy individuals or patients through various literature reviews. With the development of CT technology, recent studies have been conducted in asymptomatic CAD patients with a reduced radiation dose of less than 1 mSv. A total of 2.6% of asymptomatic subjects on CCTA found significant CAD over 70%, and it was concluded that screening CCTA for CAD showed prognostic power in predicting the future occurrence of CAD in asymptomatic people. However, after the completion of the current NIH SCOT-HEART 2 study, it may be possible to determine whether CCTA is appropriate as a screening tool for CAD in asymptomatic healthy individuals.

The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA) (관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가)

  • Jung, Kang-Kyo;Lee, Mi-Hwa;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about $4.8{\pm}0.3bpm$ (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less $6.0{\pm}1.0mSv$ (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.

Right Coronary Artery to Left Ventricular Fistula with a Giant Right Coronary Artery Aneurysm - A case report - (거대 우관상 동맥류를 동반한 우관상 동맥에서 좌심실로 유출되는 관상 동맥루 - 1예 보고 -)

  • Kang, Joon-Kyu;Huh, Jae-Hak;Chang, Ji-Min;Song, Cheol-Min
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.296-299
    • /
    • 2010
  • A right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm is a very rare condition. This requires surgical treatment because of the possibility of rupture of aneurysm, heart failure and infective endocarditis. A 47 years old male patient with dyspnea on exertion for 3 months was diagnosed as having a right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm according to the CT and coronary artery angiography. We resected the aneurysm and performed a coronary artery bypass graft.

Valve-Sparing Root Replacement in a Turner Syndrome Patient with Bicuspid Aortic Valve and Juxtacommissural Origin of the Right Coronary Artery: A Case Report

  • Son, Dong Hyeon;Cho, Sungkyu;Song, Mi Kyoung
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.413-416
    • /
    • 2022
  • A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.