• Title/Summary/Keyword: corneal

Search Result 376, Processing Time 0.03 seconds

The Study of the Corneal Diopter Power and Corneal Radius on the Contact Lens Wear of the Korean Female in the Twenties Age (20대 한국여성의 콘택트 렌즈 착용자에 대한 각막 굴절력과 곡률반경에 대한 연구)

  • Kim, Douk-Hoon;Hwang, Sun-Hyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.127-131
    • /
    • 1997
  • An analysis on the corneal diopter power and corneal radius has been carried out the Korean female in the twenties age. The results were as follows. The most contact lens wears have the early stage of the twenties age, but the increase of aging have a decrease. The mean corneal diopter power on the right eye have 44.04 diopter, but left eye have 43.92 diopter. The mean of corneal radius on the right eye have the 7.66 mm, but left eye have the 7.69 mm. As a results, In increasing of the age, Most mean corneal diopter power have increase, but the mean of corneal radius have not change.

  • PDF

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

The Analysis of Corneal Patterns in Korean 20s by Corneal Topography and Corneal Radii by Astigmatic Degree (각막지형도를 이용한 20대의 각막형상 및 난시도에 따른 각막곡률반경의 분석)

  • Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.273-281
    • /
    • 2011
  • Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.

Successful Surgical Treatment of Feline Acute Bullous Keratopathy and Corneal Perforation with a Conjunctival Hood Graft

  • Kim, Joon Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.204-207
    • /
    • 2017
  • We report the successful treatment of feline acute bullous keratopathy (FABK) and corneal perforation with a conjunctival hood graft. Two cats with FABK and corneal perforation had severe corneal edema with large central bullae. Their corneas were thinned and perforated. Conjunctival hood grafts were performed. All corneas recovered after 3-4 weeks. The grafts were then removed from the cornea using superficial keratectomy and no ocular irritation was observed. One month later, the corneas had recovered, although there was very mild fibrosis. The cats had normal vision without any corneal problems at this time. Conjunctival hood graft was thus useful for the treatment of severe FABK and allowed the cats to maintain vision.

Autologous Lamellar Keratoplasty for the Treatment of Feline Acute Bullous Keratopathy: A Case Report

  • Manbok Jeong
    • Journal of Veterinary Clinics
    • /
    • v.40 no.4
    • /
    • pp.303-307
    • /
    • 2023
  • A 4-year-old female Munchkin cat presented with a 2-day history of a large mass in the left eye. On the first presentation, slit lamp biomicroscopy revealed a large corneal bulla occupying around 40% of the corneal surface along the visual axis. Based on the results, a diagnosis of feline acute bullous keratopathy was made. Due to the location of the extensive corneal bulla, autologous lamellar keratoplasty was performed based on prior studies, to both minimize postoperative complications that may affect axial vision and address any cosmetic concerns the owner had. The autologous lamellar keratoplasty successfully resolved the corneal bulla with no signs of corneal opacities postoperatively. Therefore, autologous lamellar keratoplasty may be a useful surgical treatment for feline acute bullous keratopathy from both the tectonic and optical points of view.

The Change of Corneal Refractive Power by Everted Silicone Hydrogel Contact Lens Wear (역방향 실리콘 하이드로겔 렌즈 착용에 따른 각막 굴절력 변화)

  • Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • Purpose: The purpose was to study the corneal refractive power changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The corneal refractive power and corneal astigmatism were measured using corneal topographer (CT-1000, Shin-nippon Co., Japan) for checking change of corneal refractive power and objective refractive error was measured by auto-refractometer (Natural vision-K 5001, Shin-nippon Co., Japan). We measured at baseline and 1 week after lens wearing. Results: The correcting of corneal refractive power could be effective in low myopia. It's more effective to the higher power of greatest meridian of cornea and the more corneal astigmatism. 73% of subjects' refractive error was decrease less than 1 D and 17% of the subjects had an reverse effect (increase) occurs. The reduction of objective refractive error was more effective when cornea refractive power was great or corneal astigmatism was much. Conclusions: Pressure which the everted silicone hydrogel lens to the cornea could be caused. It occurred as the degrees of corneal power, corneal astigmatism and objective refractive error differences. Selection of an appropriate subject is important considering difficulty of changing the parameters of the lens.

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

Safety and outcomes of subconjunctival allogenic mesenchymal stem cell transplantation in canine experimental corneal defects

  • Kim, Ju-Won;Lee, So-Young;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.3
    • /
    • pp.157-162
    • /
    • 2012
  • Corneal injury is very common clinical condition in veterinary medicine and delayed or incomplete corneal healing has the potential of vision loss due to the loss of corneal transparency. For the reconstruction of corneal epithelium, tissue graft and cell transplantation have been prosperously investigated. The purpose of this study was to evaluate the clinical value and short-term safety of application of cultured allogenic mesenchymal stem cells (MSCs) in the treatment of canine experimental corneal defect. Corneal defects were surgically generated in the central corneas of healthy beagle dogs and cultured canine allogenic MSCs were transplanted via subconjunctival injection. Although mean healing time, the rate of epithelial regeneration, and the degree of corneal transparency were not significantly improved after MSC transplantation, significant immune reaction or incompatibility reaction was not detected except transient local irritation. These results propose the possibility of MSC application as a new regenerative medicine in canine ocular disorders.

Evaluation of Bovine Amniotic Membrane for the Treatment of Superficial Canine Corneal Ulcer (개의 표재성 각막 궤양에서 소의 양막을 이용한 치료에 대한 평가)

  • Choi, Young-Min;Kim, Joon-Young;Park, Jong-Im;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.358-366
    • /
    • 2007
  • This study was performed to investigate the application of bovine amniotic membrane for canine corneal ulcer and to compare bovine amniotic membrane flap to nictitating membrane flap. Corneas were treated with 8.0mm trephine and 100% ethanol was applied and corneal epithelium was removed. This experiment was divided into three groups; control group, nictitating membrane flap group and amniotic membrane + nictitating membrane flap group. To compare corneal healing, fluorescein dye test, histopathological examination and TUNEL assay were performed. The healing size of the corneal epithelium in was largest among groups and it was significantly different with the other groups (P<0.05). Also, inflammatory cell deposits and keratocyte apoptosis in amniotic membrane flap group were smallest, but the width of the corneal epithelium was thickest among groups. Therefore, we tentatively predicted that the amniotic membrane flap would be an alternative effective method for the treatment of superficial canine corneal ulcer.