• Title/Summary/Keyword: core stability

Search Result 651, Processing Time 0.032 seconds

Dynamic stability and nonlinear vibration of rotating sandwich cylindrical shell with considering FG core integrated with sensor and actuator

  • Rostami, Rasoul;Mohamadimehr, Mehdi;Rahaghi, Mohsen Irani
    • Steel and Composite Structures
    • /
    • v.32 no.2
    • /
    • pp.225-237
    • /
    • 2019
  • In this research, the dynamic stability and nonlinear vibration behavior of a smart rotating sandwich cylindrical shell is studied. The core of the structure is a functionally graded material (FGM) which is integrated by functionally graded piezoelectric material (FGPM) layers subjected to electric field. The piezoelectric layers at the inner and outer surfaces used as actuator and sensor, respectively. By applying the energy method and Hamilton's principle, the governing equations of sandwich cylindrical shell derived based on first-order shear deformation theory (FSDT). The Galerkin method is used to discriminate the motion equations and the equations are converted to the form of the ordinary differential equations in terms of time. The perturbation method is employed to find the relation between nonlinear frequency and the amplitude of vibration. The main objective of this research is to determine the nonlinear frequencies and nonlinear vibration control by using sensor and actuator layers. The effects of geometrical parameters, power law index of core, sensor and actuator layers, angular velocity and scale transformation parameter on nonlinear frequency-amplitude response diagram and dynamic stability of sandwich cylindrical shell are investigated. The results of this research can be used to design and vibration control of rotating systems in various industries such as aircraft, biomechanics and automobile manufacturing.

The Effect of Core Stabilization Exercise on Dynamic Balance and Trunk Horizontal Rotation in Adult Men (코어 운동이 성인 남성의 동적 균형과 몸통의 수평 회전에 미치는 효과)

  • Gyeong Hyeon, Jeong;Byounghee, Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.4
    • /
    • pp.96-111
    • /
    • 2022
  • Background: This study aims to evaluate the effect of core stabilization exercise on the dynamic balance and horizontal rotation of the trunk in young adult men. Through this study, it is expected that various core stabilization exercises will prevent and treat musculoskeletal disease. Design: Randomized Controlled Trial. Methods: The study subjects were recruited from young adult men in their 20s and 30s living in Seoul, and after the randomized controlled trial, it was divided into an experimental group training core stabilization exercise(n=15) and a control group(n=15). The evaluation methods of this study were modified Star Excursion Balance Test(mSEBT), Functional Reach Test(FRT), and Trunk Rotation Test(TRT). The experimental group performed three sets of crunches and deadbug exercises twice a week for eight weeks, and the control group did not perform any exercises similar to core stabilization exercise during the experimental period. Results: The result of the experiment, the experimental group showed significant improvement in mSEBT(p<.05), FRT(p<.05) and TRT(p<.05). Conclusion: In conclusion, core stabilization exercises improved dynamic balance and horizontal rotation of the trunk. As a result of this study, core stabilization exercise can prevent and treat musculoskeletal diseases even in healthy people.

Internal Flow Stability for Tangential Entry Conditions in a Swirl Injector (스월 인젝터에서 접선방향 유입구 조건이 내부유동의 안정성에 미치는 영향에 대한 연구)

  • Kim, Sung-Hyuk;Khil, Tae-Ock;Cho, Seong-Ho;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.6
    • /
    • pp.30-37
    • /
    • 2008
  • Many theoretical and experimental studies have been conducted to investigate elements of swirl injector hydrodynamics, such as variations in liquid film thickness or air core diameter. From these studies, some theoretical relationships have been established through an approximate analytical solution of flow hydrodynamics in a swirl nozzle. However, experimental studies on elements such as the stability of internal flow have not produced conclusive results. In this study, the stability of the internal flow under tangential entry conditions was examined by visualizing the formation of the air core in the swirl chamber and measuring the liquid film thickness in the orifice.

Studies on Manufacture of Thin Composite Panel for Substitute Use of Plywood (II) - Development of Thin Composite by Composition Type Applied to Optimum Manufacturing Condition - (합판(合板) 대용(代用) 박판상(薄板狀) 복합재(複閤材) 제조(製造)에 관(關)한 연구(硏究) (II) -최상제조조건(最適製造條件)을 적용(適用)한 구성형태별(構成形態別) 박판상(薄板狀) 복합재(複閤材) 개발(開發)-)

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.74-84
    • /
    • 1995
  • Eight types of thin composite panels were manufactured by press-lam and mat-forming process applied to optimum manufacturing condition, studied in former first research by author (1995). They were tested and compared with control boards on dimensional stability, internal bond strength, tensile strength, Screw withdrawal strength, and bending properties. These thin composite panels manufactured by mat-forming process were generally superior to those by press-lam in dimensional stability and mechanical properties. In the dimensional stability and mechanical properties of thin composite panels manufactured by mat-forming process, the thin composite panels (A and E type) composed of particle or sawdust core and veneer face with polyethylene film, were as good as those of common plywood (control board). Internal bond strength showed highest value in the thin composite panel(D type) which composed of particle core and polypropylene screen face with polyethylene film. The thin composite panels(G and H type) composed of sawdust or particle core and polypropylene screen face with polyethylene film by press-lam and mat-forming process, showed most highest value in dimensional stability and water absorption.

  • PDF

Comparison of Coverage-Dependent Adsorption Structures of Alanine and Leucine on Ge(100): Bonding Configuration and Adsorption Stability

  • Park, Yeong-Chan;Yang, Se-Na;Kim, Jeong-Won;Lee, Han-Gil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.215-215
    • /
    • 2011
  • The bonding configuration and adsorption stability of alanine and leucine adsorbed on Ge(100)-2${\times}$1 surface were investigated and compared using core-level photoemission spectroscopy (CLPES) and density functional theory (DFT) calculations. The bonding configuration, stability, and adsorption energies were evaluated for two different coverage levels. In both cases, the C 1s, N 1s, and O 1s core-level spectra at a low coverage (0.30 ML) indicated that the carboxyl and amine groups participated in bonding with the Ge(100) surface in an "O-H dissociated-N dative bonded structure". At high coverage levels (0.60 ML), both this structure and an "O-H dissociation bonded structure" were present. As a result, we found that alanine adsorbs more easily (lower adsorption energy) than leucine on Ge(100) surfaces due to less steric hindrance of side chain.

  • PDF

Au-Ag Core Shell Nanowire Network for Highly Stretchable and Transparent Supercapacitor Applications (금-은 코어쉘 나노 와이어 제조 및 투명, 유연 슈퍼캐패시터 전극으로의 활용에 관한 연구)

  • Lee, Ha-Beom;Gwon, Jin-Hyeong;Jo, Hyeon-Min;Eom, Hyeon-Jin;Go, Seung-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.183.1-183.1
    • /
    • 2016
  • Due to the latest research trend toward wearable energy devices, transparent and stretchable supercapacitors which can sustain their performance even under physical deformation have steadily attracted huge attention. Despite the Ag NW is the most promising candidate for fabrication of transparent and stretchable electronics, the electrochemical instability interrupts its application to development of the energy device. Here, we introduce a transparent and highly stretchable supercapacitor made by Au-Ag core shell NW network percolation electrode. The Au-Ag core shell NW synthesized by a simple solution process not only shows excellent electrical conductivity but also greatly enhanced chemical and electrochemical stability compare to pristine Ag NW. These outstanding properties of the Au-Ag core shell NW are attributed both to the core Ag NW and the Au protecting sheath layer. The proposed Au-Ag core shell NW based supercapacitor exhibits optical transmittance with outstanding mechanical stability withstanding 60% strain without any decrease of the performance. The supercapacitors connected in series are charged and discharged stable in 30% strain turning on a red LED. These notable results demonstrate the potential of the Au-Ag core shell NW as a strong candidate for development of wearable energy devices.

  • PDF

Comparative Analysis of Muscles Activation relate to Core Stability during 5 Therapeutic Exercise in Children with Spastic Diplegia (경직성 양하지 마비아의 5가지 치료적 운동시 핵심 안정성과 관련된 근활동 비교 분석)

  • Seo, Hye-Jung;Kim, Joong-Hwi;Shin, Hyun-Hee;Yoo, Sung-Hwan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.4
    • /
    • pp.583-592
    • /
    • 2013
  • PURPOSE: This study aimed to investigate muscles activation relate to core stability during 5 therapeutic exercise in children with spastic diplegia. METHODS: The subjects of this study were 8 children with typical development and 12 children with spastic diplegia who have been treated in Bobath children's hospital, all of whom agreed to participate in the study. All subjects were measured to see their muscles activation of rectus abdominalis, external oblique abdominalis, elector spinae, gluteus maximus, rectus femoris, and semitendinosus with surface EMG. RESULTS: The results of this study were as follows : 1) There were statistically significant difference in the root mean square(RMS) of all muscles according to 5 therapeutic exercise in children with spastic diplegia. 2) There were statistically significant difference in the RMS of all muscles according to 5 therapeutic exercise in children with typical development. 3) Significant differences of the RMS between diplegic children and normal children were found in elector spinae and rectus femoris only curl-up exercise. CONCLUSION: As the above results, we suggest that 5 therapeutic exercises could be used for a core stability or core strengthening program. Depending on the individual needs of children with cerebral palsy, some of exercises may be more beneficial than others for achieving strength.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

The comparisons of effect of core muscle strengthening by the surface conditions (지지면 조건에 따른 코어근육 강화효과의 비교)

  • Kim, Jung Hee;Kim, Jun Ho;Park, Byoung Woo;Kim, So Mang;Lee, Sun Wook;Kim, Min Kyung;Kim, Na Yul;Yun, So Jung;Hwang, Hye Min;Kim, Yun Jung;Ju, Sun Yiung
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: The objective of this study was compare the effect of core muscle strengthening between core exercise on stable surface and core exercise on unstable surface. Methods: Thirty-nine adults participated in this study and were randomly allocated to three groups. The stable surface exercise group and unstable surface exercise groups practiced core muscle training for $3{\times}30minute$ sessions over a 4-week period. The control group did not received therapeutic intervention except pre and post test. The following clinical tools were used to assess core muscle strength and balance: Side Plank Test, Trunk Flexion Test, Balance Error Scoring Test, Core Muscle Stength & Stability Test. Results: The stable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part as revealed by the Side Plank Test and Trunk flexion Test(p<.05). The unstable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part and balance ability as revealed by the Balance Error Scoring Test and Core Muscle Strength & Stability Test(p<.05). Conclusion: The results of this study, both core exercise on stable surface and core exercise on unstable surface induced core muscle strengthening and balance ability. Expecially core exercise on unstable surface more effective to core muscle strengthening and balance ability.

  • PDF

A study of Polymerization and Thermal Characteristics of Core-Shell Emulsion particles

  • Kim, Nam-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.10-14
    • /
    • 2011
  • Emulsion polymerization was carried out using RMA like MMA, EMA, BMA and Styrene(St.) as monomer for core-shell latex preparation. It was synthesized at $80^{\circ}C$ in the presence of anionic surfactant SLS. FT-IR, TGA and DSC analysis are used to confirm synthesized core-shell emulsion latexes and to investigate the thermal characteristics of them. From analysis of TGA and DSC, the differences of the decomposition rate and the activation energy are not so large. It considers that the pendent group is not affect of the thermal characteristics and stability on core-shell latexes, which is synthesized with RMA and Styrene.