• 제목/요약/키워드: cooling-off

검색결과 224건 처리시간 0.028초

MANAGING A PROLONGED STATION BLACKOUT CONDITION IN AHWR BY PASSIVE MEANS

  • Kumar, Mukesh;Nayak, A.K.;Jain, V;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.605-612
    • /
    • 2013
  • Removal of decay heat from an operating reactor during a prolonged station blackout condition is a big concern for reactor designers, especially after the recent Fukushima accident. In the case of a prolonged station blackout condition, heat removal is possible only by passive means since no pumps or active systems are available. Keeping this in mind, the AHWR has been designed with many passive safety features. One of them is a passive means of removing decay heat with the help of Isolation Condensers (ICs) which are submerged in a big water pool called the Gravity Driven Water Pool (GDWP). The ICs have many tubes in which the steam, generated by the reactor core due to the decay heat, flows and condenses by rejecting the heat into the water pool. After condensation, the condensate falls back into the steam drum of the reactor. The GDWP tank holds a large amount of water, about 8000 $m^3$, which is located at a higher elevation than the steam drum of the reactor in order to promote natural circulation. Due to the recent Fukushima type accidents, it has been a concern to understand and evaluate the capability of the ICs to remove decay heat for a prolonged period without escalating fuel sheath temperature. In view of this, an analysis has been performed for decay heat removal characteristics over several days of an AHWR by ICs. The computer code RELAP5/MOD3.2 was used for this purpose. Results indicate that the ICs can remove the decay heat for more than 10 days without causing any bulk boiling in the GDWP. After that, decay heat can be removed for more than 40 days by boiling off the pool inventory. The pressure inside the containment does not exceed the design pressure even after 10 days by condensation of steam generated from the GDWP on the walls of containment and on the Passive Containment Cooling System (PCCS) tubes. If venting is carried out after this period, the decay heat can be removed for more than 50 days without exceeding the design limits.

SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Ko, Jae-Hun;Park, Jea-Ho;Jung, In-Soo;Lee, Gang-Uk;Baeg, Chang-Yeal;Kim, Tae-Man
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.547-556
    • /
    • 2014
  • Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

브로콜리 수확후 관리의 최근 연구 동향 (Recent Research Status of Postharvest Management of Broccoli)

  • 최지원;이우문;곽정호;김원배;김지강;이승구;조미애
    • 한국국제농업개발학회지
    • /
    • 제23권5호
    • /
    • pp.497-502
    • /
    • 2011
  • 브로콜리는 항암기능 및 항산화 물질로 알려진 글루코시놀레이트와 플라보노이드를 다량 함유하고 있어 최근 우리나라에서도 생산 및 소비가 급증하고 있는 채소이다. 그러나, 브로콜리는 신선 농산물 중에서 호흡율이 매우 높아 수확 후 품질 수명이 짧은 단점을 갖고 있다. 브로콜리의 수확 후 품질에 영향을 미치는 주요 요인으로는 화뢰의 황화현상, 시들음, 이취, 부패 등이 있으며, 1-MCP, 에탄올, UV-C, 열처리 등과 같은 수확 후 처리기술을 사용하여 우수한 품질을 유지하는 것이 가능하다. 특히 예냉과 저온저장을 포함하는 콜드체인 시스템은 저장 수명 연장 및 우수 품질을 유지하기 위한 가장 좋은 방법으로 제시되고 있다. 적정 저장 온도는 0℃, 상대 습도는 95~100%가 바람직하며, CA 저장 또는 MA포장을 통해 저장성을 높이는 방법으로 1-2% O2+ 5--10% CO2의 공기조성이 제시되고 있다. 건강채소로 각광받고 있는 브로콜리는 수확시기에 따라 가격변동성이 높고, 기후변화에 의한 생산량 예측이 어려워 저장에 따른 품질 유지가 재배농가의 소득에 직접적인 영향을 미친다고 볼 수 있다. 따라서 본 연구는 브로콜리의 수확에 따른 생리적 변화 특성을 이해하고, 저장방법 및 유통 단계별 품질 저하를 최소화 할 수 있는 종합적인 관리방법의 연구동향을 파악하고자 하였다.

토양온도(土壞溫度)가 벼와 피의 출아속도(出芽速度)에 미치는 영향(影響) (Effect of Soil Temperature on the Emergence - Speed of Rice and Barnyardgrasses under Dry Direct - Seeding Condition)

  • 권용웅;김도순;박상원
    • 한국잡초학회지
    • /
    • 제16권2호
    • /
    • pp.81-87
    • /
    • 1996
  • 벼와 피 종자의 출아 및 초기생육에 미치는 토양온도의 영향을 파악하고자 온도구배가 10~$30^{\circ}C$ 사이에서 직선적으로 이루어지도록 알루미늄의 열전도(熱傳導) 특성을 이용하여 온도구배장치를 제작하여 실험하였다. 온도구배장치는 알루미늄괴(塊)(가로 80cm${\times}$세로 150cm${\times}$높이 10cm)에 직경 3cm, 깊이 3cm의 구멍을 4cm 간격으로 가로 방향으로는 8개씩, 세로 방향으로는 16개씩 총 128개(8${\times}$16)의 구멍을 뚫었다. 온도조절을 위하여 한쪽에는 열전대 온도센서와 히터를 부착하였고, 다른 쪽에는 열전대 온도센서와 냉각수 순환파이프를 삽입 장착하였다. 본 실험에 앞서 물피, 돌피, 강피의 발아력(發芽力)을 검증하여 각각 발아율이 88.7, 84.6, 72.6% 이상인 종자를 구멍당 20립씩(3반복) 2.5cm 심도로 파종하고 벼 육묘용(育苗用) 상토(床土)로 복토하여 실험(寶驗)한 결과(結果)는 다음과 같이 요약(要約)된다. 1. 일품벼의 최종발아율(最終發芽率)은 $20^{\circ}C$ 까지는 토양온도(土壞溫度)에 비례하여 급격히 증가(增加)하는 경향(傾向)을 보였고 그 이상의 온도에서는 거의 일정하여 80~100% 의 최종출아율을 나타냈으며, 피의 경우에는 11~$30^{\circ}C$ 사이에서 출아율(出芽率)이 거의 직선적(直線的)으로 증가하였다. 2. 평균출아일수(平均出芽日數)는 토양온도(土壞溫度)가 증가(增加)함에 따라 벼의 경우 지수함수적(指數函數的)으로 짧아졌고, 피는 초종에 관계없이 거의 직선적(直線的)으로 감소하였으며, 물피<돌피<강피순으로 짧았다. 3. 벼에 있어서 온도(溫度)에 따른 출아속도차이(出芽速度差異)는 최초출아, 25%, 50% 및 75% 출아까지에 소요(所要)되는 시간(時間)간에 고도로 유의한 상관관계가 있었고 출아율 조사는 어느 시기에 하더라도 동일한 경향을 나타낼 것으로 판단된다. 4. 일품벼의 출아한계온도(出芽限界溫度)는 $12.3^{\circ}C$, 피에 있어서는 초종에 관계없이 벼 보다 낮은 $11^{\circ}C$ 정도이었고, 일품벼를 13$^{\circ}C$에 파종했을 때 출아시(出芽始)까지 소요시간(所要時間)은 약 26.7일(日), 피의 경우에는 초종간에 큰 차이가 없이 10~11일(日)이면 출아시(出芽始)에 도달하였다. 5. 벼 직파재배(直播載培)에 있어서 휴면(休眠)이 타파(打破)된 피는 10~$30^{\circ}C$ 온도범위에서 출아소요일수(出芽所要日數)가 벼보다 항상 짧아 경합(競合)에 유라(有利)할 뿐만 아니라, 특히 18$^{\circ}C$ 이하( 以下)에서는 벼의 출아소요기간(出芽所要期間)이 피 보다 현저히 길어 피의경함력(競合力)이 더욱 커질 수 있는 근거(根據)가 됨을 알 수 있었다.

  • PDF