• Title/Summary/Keyword: cooling trend

Search Result 142, Processing Time 0.023 seconds

Recent Trends in Flat Hot Rolling of Steel (열간 압연판재 제조기술의 최신동향)

  • 이준정
    • Transactions of Materials Processing
    • /
    • v.11 no.1
    • /
    • pp.24-35
    • /
    • 2002
  • Recent trend and future prospect of flat rolling of steel has been summarized based on the earlier reports. Key technology in the plate rolling is to have ultra fine microstructure having high resistance against crack propagation during application. Heavy accelerated cooling facility and high power rolling mill will be helpful to develope the high toughness steel. Precise modeling of properly prediction based on deformation and transformation imposed on microstructure of steel during processing is highly anticipated. For the hot strip rolling process, new trend is lies on the production of ultra-thin gauged hot strip to substitute cold rolled strip. For the substitution of cold rolled strip into hot rolled strip widely, high formable property of hot strip is highly required. For the formabilit, the ferritic rolling of extra low carbon steel under high lubricated condition is essential. Recently introduced semi-continuous thin slab and rolling mill line is very plausible to develope those kinds of products easily In the view groin facility combination. New idea to modify the existing continuous hot strip mill line to produce the ultra thin-gauged hot strip in an economic way is suggested in this report.

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

Trend on the Recycling Technologies on the High-efficiency Rapid Cooling Method of Ladle Furnace Slag by the Patent and Paper Analysis (특허와 논문으로 본 제강 환원슬래그의 고효율 급냉 자원순환기술 동향)

  • Kim, Jin Man;Cho, Young-Ju;Cho, Bong-Gyoo
    • Resources Recycling
    • /
    • v.23 no.2
    • /
    • pp.90-97
    • /
    • 2014
  • The artificial dry silica used as dry aggregates in domestic is collected increasing every year. It is required drying process for the production of dry aggregates, therefore, it is main culprit of the cost up of aggregates and air pollution by using fossil fuel for the solution, it is developed alternative aggregates for the replacement of dry aggregates very ungently. In this article, the patents and papers for the recycling technology on the high-efficiency rapid cooling method of ladle furnace slag were collected and analyzed. The open patents of USA (US), European Union (EP), Japan (JP), and Korea (KR) and SCI journals from 1977 to 2013 were investigated. The patents and journals were collected using key-words and filtered by the definition of the technology. The patents and journals were analyzed by the years, countries, companies, and technologies and the technical trends were discussed in this paper.

A Study on Freezing Efficiency Improvement of Horizontal-Plate Freezer for Fishing Vessel (어선용 수평 냉각판 냉동장치의 냉동 효율 개선에 관한 연구)

  • Lee, Jae-Chul;Jeong, Ji-Ho;Kim, Byung-Mok;Shin, Sung-Chul;Kim, Soo-Young;Jeong, Bo-Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • The economic efficiency for fishery products can be related to their freshness and the quality. In order to freshly storage the product, freezing equipment system is necessary for fishing vessels. For this purpose, the horizontal plate freezer (HPF) is mostly used. In this research, our major objective is to improve the freezing performance of the HPF. Therefore, it is important to analyse the relationship between the shape of channels and the cooling temperature of the HPF. In order to save calculation time while checking the trend analysis between shape and performance, we used scaled models, and evaluate the cooling temperature of full scale model based on trend analysis results. The produced HPF in domestic was used, and the same operating conditions are considered. Based on this paper, the future research will be a comparison and verification through the experiments.

Analysis of the cooling and heating degree days in the Seoul and Yeosu, where HadCM3 is applied (서울과 여수지역에 HadCM3를 적용한 냉」난방도일의 변화량 분석)

  • Yoo, Ho Chun;Noh, Kyoung Hwan
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.11-16
    • /
    • 2009
  • To act and respond to the climate changes and to bring about power-saving in buildings, the changes in the atmospheric data in Korea are recorded and assessed. For the two regions representative of Korea, the data obtained from HadCM3 and actual data are compared and analyzed so as to concretely evaluate and confirm the changes taking place in the cooling and heating degree days in Korea. For the past 40 years, from 1996 to 2005, the number of heating degree days was on the decline and in the two representative regions, between 1980's and 1990's, the number of decrease in the heating degree days had been quite large. The number of cooling degree days showed a trend of increase since the 1970's and just as in the case of heating degree days, the extent of increase was quite large between the 1980's and the 1990's. The results of comparison of the number of heating and cooling degree days, one obtained from the "Korea Meteorological Administration" and another from the HadCM3 data (E127.5,N37.5,E127.5,N35), which is one of the ways of predicting the climate, showed similar trends in the number of heating degree days in the Yeosu area. However, in the case of the number of heating degree days in Seoul and the number of cooling degree days both in Seoul and Yeosu, the differences in the number ranged from a minimum of 300 days to a maximum of 1500 days. This could be attributed to the grid points used in the HadCM3, the differences in the values of latitudes and longitudes of these two locations considered in this study, topographical differences, heat island effect caused by population density etc. and while using the HadCM3, these variables factors must be taken into consideration.

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Trends of Stability Indices and Environmental Parameters Derived from the Rawinsonde Data over South Korea

  • Eom, Hyo-Sik;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.32 no.5
    • /
    • pp.461-473
    • /
    • 2011
  • In this paper, trends of the widely used stability indices (SIs) and environmental parameters (EPs) were examined by using the 30-year routine rawinsonde data observed in three upper air observatories (Osan, Gwangju and Pohang) over South Korea. To take into account of the contribution of water vapor to a parcel density, we applied the virtual temperature correction in calculating the SIs and EPs. The trends of SIs and EPs indicated significant increases of temperature and moisture contents, especially at the low-to-mid troposphere during the last 10 years. The warming trend in the lower troposphere shows about 3 times greater than that of the global average (+0.10- $+0.20^{\circ}C$/10 years), whereas the cooling trend of lower stratosphere demonstrates a similar trend with the global average (-0.33- $-0.60^{\circ}C$/10 years). The vertical stability is clearly reduced due to the unsymmetrical change of atmospheric elements. The unstabilizing trend with the increased moisture contents gradually changed the atmospheric environment in South Korea into the conditions favorable for the occurrence of severe weather or intensifications of such events. These trends are consistent with the recent observations, which showed clear increase in the intensity and frequency of heavy rainfalls.

A Technical Trend of Manufacturing and Materials of Nozzle Extension for Thrust Chamber of Liquid Rocket (액체로켓 연소기 노즐확장부 제작 및 재료 기술 동향)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.97-103
    • /
    • 2012
  • The combustion chamber and nozzle of a liquid rocket engine should be protected from the high temperature combustion gas generated by the chamber. An upper-stage nozzle extension has a large expansion ratio, therefore, The light-weight refractory materials have been used since the weight impact on the launcher performance is crucial. Gas film cooling method was used before, but was not applicable nowadays. Ablative cooling method and radiative cooling method with niobium alloy, Ni-based superalloy and ceramic based composite have been used to this day.

Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store (TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

Performances of Hot Gas Bypass Type Oil Cooler System (Hot Gas를 이용한 오일쿨러의 성능평가)

  • Lee, Seung-Woo;Yeom, Han-Kil;Park, Kil-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-80
    • /
    • 2009
  • In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with machine tools. For precise temperature control, both cooling and heating should be implemented. A hot gas bypass type cooling cycle method has a simplified structure and temperature control accuracy to with in ${\pm}0.1^{\circ}C$. In this study, the performances of oil cooler system, including temperature controllability according to hot gas floe and preset temperature sustainability according to temperature load, were tested. It is expected that this study will contribute to the development and performances of oil cooler system, which could minimize thermal errors and improve the quality of precision machine tools.