• Title/Summary/Keyword: cooling time

Search Result 1,652, Processing Time 0.032 seconds

The Clinical Summary of the Coronary Bypass Surgery (심장 관상동맥 외과)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.174-185
    • /
    • 1980
  • It was my great nohour that I can be exposed to such plenty materials of the coronary bypass surgery. Here, I am summarizing the xoronary bypass surgery, clinically. The material is serial 101 patients who underwent coronary bypass surgery between July 17, 1979 to November 30, 1979 in Shadyside Hospital, University of Pittsburgh. 1. Incidence of the Atherosclerosis is frequent in white, male, fiftieth who are living in industrialized country. It has been told the etiologic factor of the atherosclerosis is hereditary, hyperlipidemia, hypertension, smoking, drinking, diabetes, obesity, stress, etc. 2. The main and most frequent complication of the coronary atherosclerosis is angina pectoris. Angina pectoris is the chief cause of coronary bypass surgery and the other causes of coronary bypass surgery are obstruction of the left main coronary artery, unstable angina, papillary muscle disruption or malfunction and ventricular aneurysm complicated by coronary artery disease. 3. The preoperative clinical laboratory examination shows abnormal elevation of plasma lipid in 82 patint, plasma glucose in 40 patient, total CPK-MB in 24 patient stotal LDH in 22 patient out of 101 patient. 4. Abnormal ECG findings in preoperative examine were 29.1% myocardial infarction, 25.8% ischemia and injury, 14.6T conduction defect. 5. Also we had done Echocardiography, Tread Mill Test, Myocardial Scanning, Vectorcardiography and Lung function test to get adjunctive benefit in prediction of prognosis and accurate diagnosis. 6. The frequency of coronary atherosclerosis in main coronary arteries were LAD, RCA and Circumflex in that order. 7. The patients' main complaints which were became as etiologic factor undergoing coronary bypass surgery were angina, dyspnea, diaphoresis, dizziness, nausea and etc. 8. For the coronary bypass surgery, we used cardiopulmonary bypass machine, non-blood, diluting prime, cold cardioplegic solution and moderate cooling for the myocardial protection. 9. We got the grafted veins from Saphenous and Cephalic vein. Reversed and anastomosed between aorta and distal coronary A. using 5-0 and 7-0 prolene continuous suture. Occasionally we used internal mammary A. as an arterial blood source and anastomosed to the distal coronary A. and to side fashion. 10. The average cardiopulmonary bypass time for every graft was 43.9 min. and aortic clamp time was 23 minute. We could Rt. coronary A. bypass surgery only by stand by the cardiopulmonary machine and in the state of pumping heart. 11. Rates by the noumbers of graft were as follow : 21.8% single, 33.7% double, 26.7% triple, 13.9% quadruple, 3% quintuple and 1% was sixtuple graft. 12. combined procedures with coronary bypass surgery were 6% aneurysmectomy, 3% AVR, 1% MVR, 13% pacer implantation and 1% intraaortic ballon setting. 13. We could see the complete abolition of anginal pain after operation in 68% of patient, improvement 25.8%, no change in 3.1%, and there was unknown in 3%. 14. There were 4% immediate postoperative deaths, 13.5% some kinds of heart complication, 51.3% lung complications 33.3% pleural complications as prognosis.

  • PDF

A study on the heat transfer characteristics during outward melting process of ice in a vertical cylinder (수직원통형 빙축열조내 외향용융과정시 열전달특성에 관한 연구 -작동유체의 유동방향 및 축열조 형상비에 따른 열성능 비교-)

  • Kim, D.H.;Kim, D.C.;Kim, I.G.;Kim, Y.K.;Yim, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.171-179
    • /
    • 1997
  • During the day time in summer, peak of air conditing load, and electric power management system lies under overloaded condition. The reason is the enlarged peak load value of electric power caused by increased air-cooling load in summer. To prevent load concentration during day time and overloaded condition of power management system, some energy storage methods are suggested. One of these methods is ice storage system. Water has some good properties as P.C.M.(Phase Chang Material) : Its melting point is the range of required operation temperature. It has large specific latent heat and is chemically stable compared to other organic or inorganic substances. It is cheap and easy to treat. This study represents experimental results of heat transfer characteristics of P.C.M. under the outward melting process in a vertical cylinder. We experimented with twelve combinations of conditions, i.e., three different inlet temperatures($7^{\circ}C,\;4^{\circ}C\;and\;1^{\circ}C$), two working fluid directions(upward and downward), and two aspect ratios, H/R(4 and 2). At the inlet temperature of $7^{\circ}C$ and $4^{\circ}C$, there was temperature stagnation region where the temperature of P.C.M. remains constant at $4^{\circ}C$ regardless of aspect ratio and direction of working fluid. This temperature stagnation occurs as the water, at its maximum density, flows down to the lower region. The phase change interface formed bell-shaped curve as the melting process continued. With a new set of conditions(4H/R, inlet temperature $4^{\circ}C$ and $1^{\circ}C$, downward/upwerd inlet direction), the movement of phase change interface was faster when the working flued inlet direction was downward. With the same set of conditions, melting rate and total melting energy were larger when the working fluid inlet direction was downward. The results were reversed when the other sets of conditions were applied.

  • PDF

Studies on the Cackroach Distribution from the House in Seoul City Area (서울시내(市內) 가주성(家住性) "바퀴"의 분포(分布)에 관(關)한 조사(調査))

  • Cha, C.W.;Ham, K.S.;Ahn, S.K.;Park, D.W.;Koo, S.H.;Han, Y.I.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1969
  • In the cities nowadays, the dwelling conditions of Cackroach are provided by use of various kinds of construction material, installation of heating and cooling facilities that maintain moderate temperature, filthy sanitation, and lack of knowledge about insect as mechanical Vector. Cakroach is infectious disease Vector, and it proves to be of much importance in the public health. Considering such importance, the author has surveyed the distribution of Cackroach in the housing areas of Seoul City from May 1969 to the end of August 1969, and has come to the following conclusion: 1. House dwelling Cackroach collected in the City of Seoul are of two species, i. e. Blatella Germanica Linneaus and Periplaneta Japonica Karny. 2. Most of cackroach collected in Seoul are Blatella Germanica Linneaus and they are distributed in whole area of Seoul while that of Periplaneta Japonica Karny is distributed only in the limited area. 3. Dwelling places of Blatella Germanica Lineaus are in grog shop, Korean food restaurants, bakery shops, and patient rooms in hospitals. Many of them are found in tile kitchens and dining rooms of restaurants, and tearooms. They live in groups at older houses with much crack, warm and humid places. 4. For method of collection, the hand collection was the most effective. In trap collection during the day time, when the trap is placed at the narrow corners off the ground after confirming the dwelling places of cackroach, the match trap was more effective than the flask trap in collecting. In case of collecting during the night time, the flask trap was much more effective method than the match trap.

  • PDF

Open Heart Surgery for Six Cases of the Conegnital Heart Disease (선천성(先天性) 심장병(心臟病)의 개심술(開心術) -6례(例) 수술경험(手術經驗) -)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Kihl Rho;Kim, Song Myung;Lee, Kwang Sook;Lee, Chong Kook
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.220-238
    • /
    • 1976
  • Six cases of congenital heart disease were operated on by means of cardiopulmonary bypass between December, 1975 and April, 1976. Two cases of ventricular septal defects (VSD), two cases of VSD, associated with ruptured aneurysm of sinus Valsalva, two cases of atrial septal defects (ASD) and one case of pulmonic stenosis with patent ductus arteriosus were operated. Sarns roller pumps and Bentley Temptrol oxygenators were used for extracorporeal circulation. Pump oxygenator was primed with Ringer's lactate solution, 5% dextrose in water, mannitol, and ACD blood. Flow rate ranged from 2.0 to $2.4L/M^2/min$. Bicarbonate was added to the oxygenator with estimated amount as 15 mEq/L/hr. Venous catheters were introduced into superior and inferior vena cava, and oxygenated blood was returned to the body through aortic cannula inserted into ascending aorta. Moderate hypothermia ($30^{\circ}C$) was induced by core cooling. Aorta was cross clamped for 15 minutes and released for 3 minutes, and repeated clamping when necessary. Atrial and ventricular septal efects were closed by direct sutures. Aneurysms of sinus Valsalva ruptured into the right ventricle were repaired through right ventriculotomy by d:rect closure with Dacron patch reinforcement. Cardiopulmonary bypass time varied from 66 to 209 minutes, and aorta cross clamping time ranged from 13 to 56 minutes. Postoperative bleeding was minimal except one case who needed for evacuation of substernal hematoma. Intra- and postoperative urinary output was satisfactory. Acid-base balance, partial pressure of $O_2$, electrolytes, and hematological changes during intra- and post-perfusion period remained at the acceptable ranges. No mortality was experienced.

  • PDF

Operatonal characteristics of the PLS linac vacuum system (PLS 선형가속기 진공계의 운전특성)

  • 김임경;박용정;김경렬;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.269-277
    • /
    • 1996
  • The vacuum systems of PLS linac provides average pressure of $2.6\times 10^{-6}$Pa under high power microwave of 54 MW peak with 4.1 $\mu \textrm s$ pulse width and 10 Hz repetition rates. The base pressure of system is$2.4\times 10^{-6}$Pa with 45$^{\circ}C$ cooling water. The outgassing rate of the system is decreased from $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$ at the initial stage after installation to $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$ at present. Total accumulated microwave energy dose is about 140 GJ per module. All ion pumps are working under saturated regime and effective pumping speeds of 60 I/s, 230 I/s ion pumps are 45 I/s, 65 I/s, 140 I/s under the operating range. Main problems occurred in recent year are troubles of ion pump controller and vacuum gauge controller, vacuum leak of energy doubler window and electron gun ceramic, and water leak in the dummy load of acceleraing columns. Total of 41 troubles with 140. 8 hours down time give good system availability of 98%. Down time can be reduced by high power waveguide valves and water dummy loads under development, and then availability is expected to be increased up to 99.5%.

  • PDF

A DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING II. SOFTWARE (열전냉각방식의 범용 CCD 카메라 시스템 개발 II. 소프트웨어)

  • Oh, S.H.;Kang, Y.W.;Byun, Y.I.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.367-378
    • /
    • 2007
  • We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E ($768{\times}512$), KAF-1602E ($1536{\times}1024$), KAF-3200E ($2184{\times}1472$) made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.

Nitrogen Conversion Factors and in vitro Protein Digestibility of some Seaweeds (수종해조의 단백계수와 in vitro Digestibility)

  • Ryu Hong-Soo;SATTERLEE Lowell D.;LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.263-270
    • /
    • 1982
  • In an attempt to evaluate the nutritional quality of seaweed protein, the effects of heat treatment on the in vitro digestibility and trypsin inhibitor content in seaweed were determined. In this study, the nitrogen-to-protein conversion factors were also calculated on the basis of quantitative amino acid data. The results are as follows : 1. The in vitro protein digestbilty of red seaweeds (P. teoera anc P. suborbiculata) were ranged from 78.5 to 82.2, and green seawerd (E. linza) and brown seaweeds showed value under 80 in vitro digestibility. In general, trypsin inhibitor contents in brown seaweed were higher (0.33-0.54 mg/g) than those of red seaweeds (0.26-0.39 mg/g). And it is noted that the lowest trypsin inhibitor content was shown in green seaweed (E. linza) in spite of lowest in spite digestibility (78.5). 2. The in vitro protein digestibility of sun dried laver (P. tenera) was increased with cooling time (microwave heating), but it was not significant. Hot plate cooking raised the in vitro digestibility from 81. 1 to 84.5. The influence pot cooking time on trypsin inhibitor content was inversely proportional to in vitro digestibility. 3. Computed nitrogen factor, based on amino acid content (Factor method) and Kjeldahl nitrogen content (Kjeldahl mettled), were 5.83 (H. fusiforme)- 6.52 (P. tencra) as Factor method and 5.40 (U. pinnatifida)-6.29 (P. tenera) as Kjeldahl method. Individual value for each nitrogen conversion factor differed by species, especially in brown seaweeds. The best estimate of the protein content of seaweed can be calculated, from multiplying the summed amino acid content by conversion factor (Factor method).

  • PDF

Crystallization Kinetics by Thermal Analysis (DTA) on Starting Glass Compositions for PDP(Plasma Display Panel) Rib (열분석에 의한 PDP 격벽용 출발유리조성의 결정화 특성 연구)

  • Jeon, Young-Wook;Cha, Jae-Min;Kim, Dae-Whan;Lee, Byung-Chul;Ryu, Bong-Ki
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.8
    • /
    • pp.721-727
    • /
    • 2002
  • In order to overcome trade-off among compositions, process and properties of the glasses with high PbO-base composition for PDP Rib, we studied glass crystallization and crystallization kinetics by Differential Thermal Analysis(DTA). Glass powder was obtained through melting/cooling/grinding, with 3 wt%TiO2 addition for the crystal nucleation and growth in $62PbO-19B_2O_3-10SiO_2-9(Al_2O_3-K_2O-BaO-ZnO)$(in wt%) composition glass. This powder was heat-treated for 1 to 10 h at $445^{\circ}C$ for nucleation. DTA measurements were performed to obtain the crystallization peak with $5∼25^{\circ}C/min$ heating rates. DTA crystallization peak temperature increased with increasing the heating rate and decreased with increasing the heating time. Because the Avrami parameter (n) was approximately 1, the surface crystallization occurred. The maximum nucleation time was 2 h.

Development of Well Placement Optimization Model using Artificial Neural Network and Simulated Annealing (인공신경망과 SA 알고리즘을 이용한 지능형 생산정 위치 최적화 전산 모델 개발)

  • Kwak, Tae-Sung;Jung, Ji-Hun;Han, Dong-Kwon;Kwon, Sun-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.28-37
    • /
    • 2015
  • This study presents the development of a well placement optimization model, combining an artificial neural network, which enables high-speed calculation, with a simulated annealing algorithm. The conventional FDM simulator takes excessive time when used to perform a field scale reservoir simulation. In order to solve this problem, an artificial neural network was applied to the model to allow the simulation to be executed within a short time. Also by using the given result, the optimization method, SA algorithm, was implemented to automatically select the optimal location without taking any subjective experiences into consideration. By comparing the result of the developed model with the eclipse simulator, it was found that the prediction performance of the developed model has become favorable, and the speed of calculation performance has also been improved. Especially, the optimum value was estimated by performing a sensitivity analysis for the cooling rate and the initial temperature, which is the control parameter of SA algorithm. From this result, it was verified that the calculation performance has been improved, as well. Lastly, an optimization for the well placement was performed using the model, and it concluded the optimized place for the well by selecting regions with great productivity.

Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller (반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구)

  • Kim, Hyeon-Joong;Kwon, Oh-Kyung;Cha, Dong-An;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1285-1292
    • /
    • 2011
  • The characteristics of a semiconductor chiller system with EEV have been experimentally studied. Three experiments on temperature changes (increase and decrease), load variation, and control precision were conducted to investigate the operating characteristics of the semiconductor chiller. The power consumption was 8.9 kW during increase in temperature. The required time was 37.5 min for CH1 and 39.5 min for CH2. Moreover, the time required for falling temperature was 26.5 min. The control precision for partial load operation was relatively low compared to that of a full load operation. In addition, the CH2 equipped with a step motor showed better control precision. The power consumed by the chiller for process cooling water was 1.8 kW, which was one-half of that consumed during the refrigeration cycle. The objective of this study is to provide an optimal control guideline for the semiconductor chiller design.