• 제목/요약/키워드: cooling temperature

검색결과 4,642건 처리시간 0.042초

히트펌프 냉·난방 시스템의 온도 자동제어에 관한 연구 (A Study for Automatic Temperature Control of the Heating-Cooling System with Heat Pump)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권4호
    • /
    • pp.143-149
    • /
    • 2011
  • The experiment has been investigated the room temperature change under adjusting 4-way valve which was installed for cooling and heating switch. Beside, the temperature of heat pump was controlled automatically for autonomously adjusting temperature and maintaining a constant room temperature. As results, Inlet & outlet temperature differences of compressor are $95^{\circ}C$ in cooling condition and $57^{\circ}C$ in heating condition. Therefore, Compression efficiency of cooling effect is higher than heating effect. In addition, Heat exchange effect of Cooling system condition is higher than heating system. This results can be used for studying about automatic temperature control of cooling and heating system with heat pump and 4way valve.

자동차용 기관의 냉각수 온도조절을 위한 서머스탯의 최적설계 변수설정에 관한 연구 (A Study on the Optimum Design Parameters of the Thermostat for Coolant Temperature Control of an Automotive Engine)

  • 박경석;신진식;원종필
    • 한국자동차공학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-16
    • /
    • 1993
  • It is widely recognized that exhaust emissions, fuel economy and engine torque are affected by engine temperature, and logic would suggest that a cooling system offering a better compromise of engine temperature would improve both overall engine performance and economy. Author measured coolant temperature of some parts and flow rate which are necessary to heat transfer in a engine. And Author determined parameters necessary for the optimum design of a thermostat to keep the best engine performance ; determined the optimum operating temperature of electric cooling fan. A summary of this study is followed. 1. Study of the effects of cooling condition to combustion character in a engine. 2. Analyze of heat transfer surrounding engine cylinders. 3. Study of the effects of cooling character to engine heat rejection, determination of the optimum collant temperature for keeping the optimum engine performance and determination of the optimum design of a thermostat for keeping that temperature.

  • PDF

얼음과 냉각수를 이용한 콘크리트의 프리쿨링에 관한 연구 (Study on Precooling of Concrete Using Ice and Cooling Water)

  • 정철헌;박장호;이순환
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2000
  • Crack control due to temperature is an important factor for the mass concrete structure. Pre-cooling is the effective system to reduce the highest temperature of mass concrete. In this study, for pre-cooling, cooling water, cooling water with ics flake are used. The results of a series of experimental studies indicate that the changes in properties of fresh concrete after cooling are of low degree, and compressive strength of concrete is changed very little by cooling. The adiabatic temperature rise is also measured with pre-cooling concrete specimens. It is shown that hydration heat characteristics of cement and concrete were largely affected by pre-cooling.

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

$Al_2O_3$ 세라믹스 열충격에 미치는 냉각 조건의 영향 (Effect of Cooling Rate on Thermal Shock Behavior of Alumina Ceramics)

  • 한봉석;이홍림;전명철
    • 한국세라믹학회지
    • /
    • 제34권7호
    • /
    • pp.767-773
    • /
    • 1997
  • Thermal shock behavior of alumina ceramics were studied by quenching the heated alumina specimen into the water of various temperatures over 0~10$0^{\circ}C$. The critical thermal shock temperature difference ( Tc) of the specimen decreased almost linearly from 275$^{\circ}C$ to 20$0^{\circ}C$ with increase in the cooling water temperature over 0~6$0^{\circ}C$. It is probably due to the increase of the maximum cooling rate which is dependent of the convection heat transfer coefficient. The convection heat transfer coefficient is a function of the temperature of the cooling water. However, the critical thermal shock temperature difference( Tc) of the specimen increased at 25$0^{\circ}C$ over 80~10$0^{\circ}C$ due to the film boiling of the cooling water. The maximum cooling rate, which brings about the maximum thermal stress of the specimen in the cooling process, was observed to increase linearly with the increase in the quenching temperature difference of the specimen due to the linear relationship of the convection heat transfer coefficient with the water temperature over 0~6$0^{\circ}C$. The critical maximum cooling rate for thermal shock fracture was observed almost constant to be about 260$\pm$1$0^{\circ}C$/s for all water temperatures over 0~6$0^{\circ}C$. Therefore, thermal shock behavior of alumina ceramics is greatly influenced by the convection heat transfer coefficient of the cooling water.

  • PDF

Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation

  • Farah, Ra'fat I.
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.3.1-3.10
    • /
    • 2019
  • Objectives: It was the aim of this study to evaluate the effect of cooling water temperature on the temperature changes in the pulp chamber and at the handpiece head during high-speed tooth preparation using an electric handpiece. Materials and Methods: Twenty-eight intact human molars received a standardized occlusal preparation for 60 seconds using a diamond bur in an electric handpiece, and one of four treatments were applied that varied in the temperature of cooling water applied (control, with no cooling water, $10^{\circ}C$, $23^{\circ}C$, and $35^{\circ}C$). The temperature changes in the pulp chamber and at the handpiece head were recorded using K-type thermocouples connected to a digital thermometer. Results: The average temperature changes within the pulp chamber and at the handpiece head during preparation increased substantially when no cooling water was applied ($6.8^{\circ}C$ and $11.0^{\circ}C$, respectively), but decreased significantly when cooling water was added. The most substantial drop in temperature occurred with $10^{\circ}C$ water ($-16.3^{\circ}C$ and $-10.2^{\circ}C$), but reductions were also seen at $23^{\circ}C$ ($-8.6^{\circ}C$ and $-4.9^{\circ}C$). With $35^{\circ}C$ cooling water, temperatures increased slightly, but still remained lower than the no cooling water group ($1.6^{\circ}C$ and $6.7^{\circ}C$). Conclusions: The temperature changes in the pulp chamber and at the handpiece head were above harmful thresholds when tooth preparation was performed without cooling water. However, cooling water of all temperatures prevented harmful critical temperature changes even though water at $35^{\circ}C$ raised temperatures slightly above baseline.

Temperature Control using Peltier Element by PWM Method

  • Pang, Du-Yeol;Jeon, Won-Suk;Choi, Kwang-Hoon;Kwon, Tae-Kyu;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1400-1404
    • /
    • 2005
  • This paper presents the temperature control of aluminum plate by using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is charged to Peltier element, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with current control and operating cooling fan only while cooling duration. Operating cooling fan only while cooling duration is proper to get more rapid heating and cooling duration. As a result of experiment, it takes about 100sec period to repeating temperature between $35^{\circ}C$ and $70^{\circ}C$ and about 80sec from $40^{\circ}C$ to $70^{\circ}C$ in ambient air temperature $25^{\circ}C$ and while operating cooling fan only in cooling duration. Future aim is to apply this temperature control method in actuating SMHA(special metal hydride actuator) which is applicable in Siver project acting in low frequency range by using Peltier element for heating and cooling.

  • PDF

정밀 오일냉각기의 오일온도 제어오차에 관한 연구 (A Study on the Oil Temperature Control Errors of Precision Oil Coolers)

  • 이상호;이찬홍;김갑순
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.451-454
    • /
    • 2003
  • The Oil Coolers is very important unit for the stable thermal performance in machine tools, semiconductor equipments and high precision measuring systems. To select a proper oil cooler for the temperature control of core unit in a machine, not only cooling ability but also static and dynamic sensitivity of temperature sensors are considered. In this paper, the relationship between cooling ability and inflow oil temperature is identified. The cooling ability is increased with the increase of inflow oil temperature. The oil temperature control errors of a cooler are influenced by mainly sensitivity of temperature sensors and heating velocity in a machine. The validity of error cause analysis for temperature control is proved by real cooling experiments with inflow and outflow temperature sensors.

  • PDF

The Effect of Exposure in Elevated Temperatures on Bending Properties of Wood

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권4호
    • /
    • pp.20-29
    • /
    • 1999
  • Temperature has important effect on mechanical properties of wood. These effect needs to be understood and taken into account in the structural use of wood. Furthermore, the effect of cooling after exposing to high temperature must be explained. In this study, the effect of temperature, exposure time, specific gravity, and cooling on bending properties were investigated. The boundary temperatures at which bending MOE and MOR reduced rapidly were approximately $200^{\circ}C$ and $150^{\circ}C$, respectively. This boundary temperature was nearly constant with independence of species(specific gravity), exposure time, and cooling. Above the boundary temperature, the effect of exposure time was increased with temperature and the reduction of bending MOE and MOR for Japanese Larch with relatively higher specific gravity was smaller than that of Hem-fir. The recovery of bending MOE and MOR after cooling was also more significant above the boundary temperature than below. The degree of cooling effect was larger for MOR than MOE. Consequently, bending properties of wood in elevated temperatures should be considered in terms of the boundary temperature, $200^{\circ}C$ for bending MOE, $150^{\circ}C$ for MOR, and these boundary temperatures must be considered an important factor. Furthermore, to evaluate the safety of structure, the recovery after cooling should be considered.

  • PDF

온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구 (An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol)

  • 김용이;임재한;한여명;김광우
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF