• 제목/요약/키워드: cooling period

검색결과 407건 처리시간 0.027초

하이브리드 지중열교환기 적용 히트펌프 시스템의 냉방 성능 분석 (Cooling Performance Analysis of Ground-Source Heat Pump (GSHP) System with Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.43-52
    • /
    • 2018
  • This paper presents the cooling performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a vertical GHE and a surface water heat exchanger (SWHE). In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the hybrid GHE, Mode 1~Mode 4. The measurement results show that the system with HGHE mainly operates in Mode 1 and Mode 2 over the entire measurement period. The average cooling coefficient of performance (COP) for heat pump unit was 5.18, while the system was 2.79. In steady state, the heat pump COP was slightly decreased with an increase of entering source temperature. In addition, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further research are needed to optimize the design data for various load ratios of the HGHE.

외기 온도 제어 방식을 적용한 지열 히트펌프 시스템의 냉방 성능 분석 (Cooling Performance Analysis of Ground-Source Heat Pump System with Capacity Control with Outdoor Air Temperature)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.68-78
    • /
    • 2021
  • In order to solve the increasing deterioration of the energy shortage problem, ground-source heat pump (GSHP) systems have been widely installed. The control method is a significant component for maintaining the long-term performance and for reducing operation cost of GSHP systems. This paper presents the measurement and analysis results of the cooling performance of a GSHP system using capacity control with outdoor air temperature. For this, we installed monitoring equipments including sensors for measuring temperature, flow rate and power consumption, and then monitored operation parameters from July 9, 2021 to October 2, 2021. From measurement results, we analyze the effect of capacity control with outdoor air temperature on the cooling performance of the system. The average performace factor (PF) of the heat pump was 6.95, while the whole system was 5.54 over the measurement period. Because there was no performance data of the existing GSHP system, it was not possible to directly compare the existing control method and the outdoor air temperature method. However, it is expected that the performance of the entire system will be improved by adjusting the temperature of cold water produced by the heat pump, that is, the temperature of cold water on the load side according to the outside air temperature.

A Study on CFD Analysis to Investigate the Effects of Different Feed Rate into the High Temperature H2SO4 Transferring Pump at Fixed Frequency

  • Choi, Jung-Sik;Choi, Jae-Hyuk
    • 해양환경안전학회지
    • /
    • 제20권3호
    • /
    • pp.304-311
    • /
    • 2014
  • In this study, to apply hydrogen energy to ship engine and to generate effective hydrogen production, we investigated the effects of high temperature $H_2SO_4$ feed rate and cooling water rate to pump parts with fixed frequency needed to reciprocate motion and a simulation was conducted at each condition. In the fixed frequency and cooling water inlet flow rate of 0.5 Hz and 3.9 kg/s, we changed the high temperature $H_2SO_4$ flow rate to 47.46 kg/s (it is 105 % of 45.2 kg/s), 49.72 kg/s (110 %), and 51.98 kg/s (115 %). Also, at 0.5 Hz and 45.2 kg/s of frequency and high temperature $H_2SO_4$ flow, the thermal hydraulic analysis was performed at the condition of 95 % (3.705 kg/s), 90 % (3.51 kg/s), and 85 % (3.315 kg/s). In overall simulation cases, the physical properties of materials are more influential to the temperature increase in the pump part rather than the changes on the feed rate of high temperature $H_2SO_4$ and cooling water. A continuous operation of pump was also capable even if the excess feed of high temperature $H_2SO_4$ of about 15 % or the less feed of cooling water of about 15 % were performed, respectively. When the increasing feed of high temperature $H_2SO_4$ of up to 5 %, 10 %, and 15 % were compared with base flow (45.2 kg/s), the deviation of time period rose to a certain temperature and ranged from 0 to 4.5 s in the same position (same material). In case of cooling water, the deviation of time period rose to a certain temperature and ranged from 0 to 5.9 s according to the decreasing feed changes of cooling water at 5 %, 10 %, and 15 % compared to a base flow (3.9 kg/s). Finally, the additional researches related to the two different materials (Teflon and STS for Pitch and End-plate), which are concerned about the effects of temperature changes to the parts contacting different materials, are needed, and we have a plan to conduct a follow-up study.

적외선 레이저의 간섭현상을 이용한 실리콘 웨이퍼의 온도 측정 (Monitoring of Silicon Wafer Temperature by IR Laser Interfermetry)

  • 김재성;이석현;황기웅
    • 전자공학회논문지A
    • /
    • 제31A권2호
    • /
    • pp.81-87
    • /
    • 1994
  • We used IR laser inteferometric technique for measuring the temperature of wafer during cryogenic ECR etching. Using this technique, the effect of RF bias power and microwave power on the wafer temperature during etching period is investigated. As the RF bias power and microwave power was increased, the temperature of the wafer considerably increased and we concluded that to prevent the increase of substrate temperature during etching period, an adequate wafer cooling is needed.

  • PDF

이상 고온 조건에서 지하수 냉방 처리가 딸기의 생육과 수량 및 품질에 미치는 영향 (Effects of Groundwater Cooling Treatment on Growth, Yield, and Quality of Strawberries under High Temperature Conditions)

  • 이규빈;이정은;최윤의;박영훈;최영환;강남준;강점순
    • 한국환경과학회지
    • /
    • 제27권8호
    • /
    • pp.631-639
    • /
    • 2018
  • A Cultivation method to minimize the damage caused by high temperatures was studied by investigating the effects of groundwater cooling treatment on the growth, yield, and quality of strawberries. In the groundwater cooling treatment, the daily average temperature of the rhizosphere was reduced from $26.9^{\circ}C$ to $24.9^{\circ}C$. The root length increased by 0.3-9.2 cm, depending on the cultivar and growth period. The leaf number, leaf area, leaf length, leaf diameter, and plant height also increased, especially in the cultivars 'Seolhyang' and 'Maehyang', resulting in higher fresh and dry weights. The number of fruit per plant increased from 7.7 to 12.5 in 'Seolhyang', and the fruit weight increased by 0.3 g in 'Seolhyang' and 1.3 g in 'Maehyang'. The fruit hardness increased, but no significant difference in fruit coloration was observed. The sugar content of the fruit was improved by $0.2-0.3^{\circ}Brix$. Therefore, groundwater cooling of the rhizosphere was effective in improving the growth and productivity of strawberries under abnormally high temperature conditions and can be considered a cost-efficient cooling system.

Study of random characteristics of fluctuating wind loads on ultra-large cooling towers in full construction process

  • Ke, S.T.;Xu, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • 제26권4호
    • /
    • pp.191-204
    • /
    • 2018
  • This article presents a study of the largest-ever (height = 220 m) cooling tower using the large eddy simulation (LES) method. Information about fluid fields around the tower and 3D aerodynamic time history in full construction process were obtained, and the wind pressure distribution along the entire tower predicted by the developed model was compared with standard curves and measured curves to validate the effectiveness of the simulating method. Based on that, average wind pressure distribution and characteristics of fluid fields in the construction process of ultra-large cooling tower were investigated. The characteristics of fluid fields in full construction process and their working principles were investigated based on wind speeds and vorticities under different construction conditions. Then, time domain characteristics of ultra-large cooling towers in full construction process, including fluctuating wind loads, extreme wind loads, lift and drag coefficients, and relationship of measuring points, were studied and fitting formula of extreme wind load as a function of height was developed based on the nonlinear least square method. Additionally, the frequency domain characteristics of wind loads on the constructing tower, including wind pressure power spectrum at typical measuring points, lift and drag power spectrum, circumferential correlations between typical measuring points, and vertical correlations of lift coefficient and drag coefficient, were analyzed. The results revealed that the random characteristics of fluctuating wind loads, as well as corresponding extreme wind pressure and power spectra curves, varied significantly and in real time with the height of the constructing tower. This study provides references for design of wind loads during construction period of ultra-large cooling towers.

주택에서의 단열성능 강화가 냉난방부하에 미치는 영향 (The Strengthening Effect of the Heating and Cooling Load on the Thermal Performance in the Housing Unit)

  • 이준기;김성훈;이갑택;이경희
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.483-488
    • /
    • 2016
  • In this study, we chose the rural house as a standard model. In order to review the energy difference of cooling and heating loads, we changed the thermal transmittance standards. By using the thermal transmittance standard in 2011 as the Basic CASE, the thermal transmittance standard in 2013 as well as 2016, and the thermal transmittance standard of passive houses, we compared the results with regard to the cooling and heating energy load. Because of the heat loss, it can be confirmed that with an improved thermal performance of the building structure, the maximum increase of the cooling energy load was 36 kWh from June to September. Because of the heat loss, it was also confirmed that with the improved thermal performance of a building structure, the maximum decrease of the heating energy load is 1,498 kWh from November to April. Even though the heat loss of the building structure could decrease the cooling energy load by improving thermal transmittance standards in Korea, the energy saving performance is worse than the situation of heating energy load in heating period. Compared with CASE 1 and CASE 2, as well as CASE 1 and CASE 3, we CASE 3 was found to have the best energy saving rate when compared to the other cases : CASE 3 increased by 1,452 kWh and CASE 2 by 588 kWh, because the window thermal transmittance standard of 2016 was added.

온도 변색 도료의 지붕 적용 및 냉방효과 분석 (Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface)

  • 백상훈
    • 토지주택연구
    • /
    • 제13권4호
    • /
    • pp.115-123
    • /
    • 2022
  • 본 연구는 지붕 표면에 온도 변색 도료(Thermochromic paint) 적용에 따른 지붕 표면 온도 저감 및 실내 냉방 효과를 분석하는 것에 목적이 있다. 본 도료는 특정 온도에서 색상이 변화되는 특징을 갖는다. 만약 본 도료를 적용함으로서 지붕 표면이 여름철에는 흰색으로, 겨울철에는 검정색으로 계절에 따라 변화될 수 있다면, 여름철에는 일사를 반사하여 실내 냉방 효과를 발휘할 수 있고, 겨울철에는 일사를 흡수하여 난방 효과를 가져올 수 있다. 이 중, 본 논문에서는 본 도료에 의해 여름철에 지붕의 표면 온도와 실내 온도가 어느 정도 감소되는지에 대해 실증 실험 및 기존 도료와의 비교를 통해 그 성능을 확인하였다. 그 결과, 온도 변색 도료가 적용된 지붕의 표면온도는 기존 도료의 경우보다 대략 5~10℃ 정도 낮게 나타났으며, 이로 인해, 실내 기온 또한 기존보다 대략 3℃ 이상 낮게 분석되었다. 따라서 온도 변색 도료는 여름철 높은 표면 온도를 유지하는 지붕에 적용 될 시, 표면 온도를 크게 감소시켜 실내 냉방효과를 발휘할 수 있는 것으로 확인되었다.

염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究) (The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt)

  • 이건목;이건휘;서은미
    • Journal of Acupuncture Research
    • /
    • 제21권1호
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

온실 포그 냉방 제어시스템 개발 및 냉방효과 (Development of Fog Cooling Control System and Cooling Effect in Greenhouse)

  • 박석호;문종필;김진구;김승희
    • 생물환경조절학회지
    • /
    • 제29권3호
    • /
    • pp.265-276
    • /
    • 2020
  • 본 연구는 여름철 고온기에 작물을 정상적으로 재배할 수 있는 환경을 조성하여 농산 가격이 가장 높은 여름철에 수확량을 높이고 재배기간을 연장시켜 농가소득을 올릴 수 있는 방안을 제시하고자 수행하였다. 바닥면적 504㎡의 연동온실의 최대 냉방부하는 462,609W로 나타났으며, 고온기에 온실을 차광하지 않고도 32℃ 이하로 유지하기 위해서는 시간당 472L의 물을 포그 분무해야 하는 것으로 나타났다. 포그 냉방 시스템은 포그 장치, 유동팬, 차광장치로 구성하고, 이들 장치를 효과적으로 제어할 수 있는 포그 냉방 자동제어장치를 개발하였다. 포그 냉방시스템의 냉방 성능은 온실 외기온 보다 내부온도를 6℃ 낮출 수 있는 것으로 나타났다. 포그 온실의 내부 상대습도는 주간에는 40~80%로 대조 온실의 20~60% 보다 약 20% 높게 나타나 오이의 생육에 기여하는 것으로 나타났다. 오이의 생육상태는 포그 온실에서 재배한 오이가 대조 온실에 비해 초장, 엽장, 엽폭, 엽수, 엽록소 값이 전체적으로 높게 나타났다. 포그 온실의 오이 수확량은 대조 온실에 비해 단동 온실에서는 1.8배, 연동 온실에서는 2배 높게 나타났다.