• Title/Summary/Keyword: cooling pattern

Search Result 262, Processing Time 0.026 seconds

Formation and Properties of Gel from Maize Starches with Different Amylose Content (아밀로오스 함량이 다른 옥수수 전분의 겔 형성과 특성)

  • 문세훈;신말식
    • Proceedings of the SOHE Conference
    • /
    • 1997.12a
    • /
    • pp.45-49
    • /
    • 1997
  • To study the effect of amylose on the mechanism of gel formation, swelling power, water solubility, the pattern of alkali gelatinization and gel properties were investigated. The swelling power of waxy maize starch(Amioca) was the highest and followed by those of PFP >Amaizo > Amylomaize Ⅶ. Amioca showed higher iodine affinity of soluble amylose than other maize starches. The apparent viscosity of alkali gelatinization measured by Brookfield viscometer for Amaizo was $70{\pm}10^3cp$ which was higher than Amylomaize VII. The apparent viscosity of PFP was increased to $70{\pm}10^3cp$ and then decreased. As maize starches were autoclaved at $121^{\circ}C$ with starch : water ratio (1:9) and autoclaving-cooling cycle were up to 4 times, gel properties were measured by rheometer. Amaizo showed the highest value for hardness, adhesiveness, springiness, cohesiveness, and hardness of gel after two times of autoclaving-cooling cycles was the highest. Gel properties was thus affected by the chain length of amylose rather than amylose content.

  • PDF

A Minerlogical Study of Plagioclase in Volcanic Rocks from the Mt. Mudeung Area (무등산지역 화산암류에서 산출되는 사장석의 광물학적 연구)

  • Park Byung-Kyu;Kim Yong-Jun;Kim Youn-Joong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.3 s.45
    • /
    • pp.155-164
    • /
    • 2005
  • Volcanic rocks from the Mt. Mudeung area which are composed of Hwasun andesite, Mudeungsan dacite and Togok rhyolite contain plagioclase phenocrysts in common. Majority of the repeated twins observed in optical microscopy are albite twin and some are pericline twin. EPMA studies of plagioclases from Hwansun andesite, Mudeungsan dacite and Togok rhyolte indicate calcic andesine, andesine-oligoclase, nearly pure albite, respectively Albite twin and pericline twin can be easily distinguished through TEM diffraction patterns, which is quite difficult by optical microscopy. Plagioclases in volcanic rocks from the Mt. Mudeung area do not show e-reflection in (100) electron diffraction patterns, probably because of their high cooling rate, which inhibited phase separations during cooling.

Observation and Analysis of Long and Short-wave Radiation According to Types of Summer Shelters (하계 그늘쉼터 유형별 장·단파복사 관측과 해석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.127-135
    • /
    • 2019
  • In this study, we analyzed the relationship between five factors: long-wave radiation, short-wave radiation, cloudiness, SVF and summer shelters. In the previous study, we recognized the correlation between single building SVF and long-wave radiation. Furthermore, this study attempted to confirm the relationship at the summer shelter with high solar radiation blocking rate. The observations are as follows. ① Cooling in summer shelters was not the effect of temperature but the effect of radiation reduction due to short-wave radiation shielding. ② In the case of the canopy tent with low heat capacity, the long-wave radiation was observed to be 16.7% higher per hour than the comparison control point due to the increase in surface temperature. ③ The long-wave radiation increase rate was different according to SVF, but showed very similar pattern according to the material characteristics of the summer shelters. ④ Passive Cooling effect on the type of summer shelters are determined by the size of the total long and short-wave radiation at that point.

Errors in the Winter Temperature Response to ENSO over North America in Seasonal Forecast Models

  • Seon Tae Kim;Yun-Young Lee;Ji-Hyun Oh;A-Young Lim
    • Journal of Climate Change Research
    • /
    • v.34 no.20
    • /
    • pp.8257-8271
    • /
    • 2021
  • This study presents the ability of seasonal forecast models to represent the observed midlatitude teleconnection associated with El Niño-Southern Oscillation (ENSO) events over the North American region for the winter months of December, January, and February. Further, the impacts of the associated errors on regional forecast performance for winter temperatures are evaluated, with a focus on 1-month-lead-time forecasts. In most models, there exists a strong linear relationship of temperature anomalies with ENSO, and, thus, a clear anomaly sign separation between both ENSO phases persists throughout the winter, whereas linear relationships are weak in observations. This leads to a difference in the temperature forecast performance between the two ENSO phases. Forecast verification scores show that the winter-season warming events during El Niño in northern North America are more correctly forecast in the models than the cooling events during La Niña and that the winter-season cooling events during El Niño in southern North America are also more correctly forecast in the models than warming events during La Niña. One possible reason for this result is that the remote atmospheric teleconnection pattern in the models is almost linear or symmetric between the El Niño and La Niña phases. The strong linear atmospheric teleconnection appears to be associated with the models' failure in simulating the westward shift of the tropical Pacific Ocean rainfall response for the La Niña phase as compared with that for the El Niño phase, which is attributed to the warmer central tropical Pacific in the models. This study highlights that understanding how the predictive performance of climate models varies according to El Niño or La Niña phases is very important when utilizing predictive information from seasonal forecast models.

Studies of Crystallographic and Magnetic Properties in Fe0.9Zn0.1Cr2S4 (Fe0.9Zn0.1Cr2S4의 결정학적 및 자기적 성질에 관한 연구)

  • Bae, Sung-Hwan;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.34-37
    • /
    • 2007
  • The crystallographic and magnetic properties of $Fe_{0.9}Zn_{0.1}Cr_2S_4$ have been studied by X-ray diffractometer(XRD), vibrating sample magnetometer(VSM) and $M\"{o}ssbauer$ spectroscopy measurement. The crystal structure was determined by the normal cubic spinel of space group Fd3m and the lattice constant was $a_0=9.9967\;{\AA}$. The specific phenomenon which looks like cusp pattern at 77 K was observed in magnetization corves(ZFC : Zero Field Cooling) under 100 Oe applied field. $N\acute{e}el$ temperature($T_N$) was determined to be 153 K by VSM and $M\"{o}ssbauer$ spectra. The asymmetric 8-line profile has been observed at 4.2 K, which was attributed by the colossal electric quadupole interaction(${\Delta}E_Q$), ${\Delta}E_Q$ has 2.22 mm/s at 4.2 K. The ${\Delta}E_Q$ abruptly decreases around 77 K and then it disappears above 77 K with diminishing of 8-line pattern. The isomer shift $\delta$ at room temperature is 0.48 mm/s relative to Fe metal, which means that the charge state of Fe ions is ferrous in character.

Analysis of Energy Consumption Pattern and Greenhouse Gas Emission in the Academic Facility (대학에서의 에너지 소비패턴 및 온실가스 배출현황 분석)

  • Kim, Jin-Sik;Lee, Kyoung-Bin;Lee, Im-Hack;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.604-612
    • /
    • 2012
  • Self-management plan for GHG (Greenhouse Gas) reduction should be prepared in academic facilities, which occupy a large amount of energy consumption. In this study, a university was chosen as one of the major academic facilities and its energy consuming pattern and GHG emission were analyzed. The results have shown that annual $CO_2$ emission from university buildings was 10,452 ton-$CO_2$ (0.65 ton-$CO_2/m^2$), and dependent upon 78.0% electricity, 20.5% LNG and 1.5% oil, respectively as energy sources. According to more detail analysis by usage of energy consumption, appliances occupies 36.7% followed by gas heating (18.9%), lighting (18.6%), heating with electricity (12.5%), cooling with electricity (10.2%), transportation (1.5%), gas cooling (1.2%) and cooking (0.4%). Furthermore, annual $CO_2$ emissions per unit area and a student by electricity usage were evaluated to 51.30 kg-$CO_2/m^2$ and 981.86 kg-$CO_2$/capita, respectively and those by LNG usage were 14.61 kg-$CO_2/m^2$ and 241.01 kg-$CO_2$/capita.

A Study on the Stretch-flangeability of Hot-Rolled High Strength Steel with Ferrite-Bainite Duplex Microstructure (페라이트-베이나이트 복합조직 고강도 열연강판의 신장플랜지 특성에 관한 연구)

  • Cho, Yeol-Rae;Chung, Jin-Hwan;Koo, Hwang-Hoe;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1252-1262
    • /
    • 1999
  • The effect of microstructures on the strength-flangeability of Nb bearing hot-rolled high strength steel was investigated in order to improve the strength-flangeability of conventional TS 580MPa grades HSLA steel for the automotive wheel disc. The low temperature coiling method using 3-step controlled cooling pattern after hot rolling was effective to produce the Nb-bearing high strength steel with the polygonal ferrite and bainite duplex microstructures. It was suggested that the suppressed precipitation of grain boundary cementites and the decreased hardness difference between ferrite matrix and bainite cause the excellent stretch-flangeability of ferrite-bainite duplex microstructure steel. Therefore, the formation and propagation of microcracks were suppressed relative to the conventional HSLA steel with ferrite and pearlite microstructure. In addition, the elongation was improved as compared with that of hot-rolled steel sheets using conventional early cooling pattern because the volume fraction of polygonal ferrite was increased.

  • PDF

Temporal and Spatial Variability of Heating and Cooling Degree-days in South Korea, 1973-2002 (한반도 난${\cdot}$냉방도일의 시공간 분포 특성 변화에 관한 연구)

  • Choi, Youn-Geun
    • Journal of the Korean Geographical Society
    • /
    • v.40 no.5 s.110
    • /
    • pp.584-593
    • /
    • 2005
  • The spatial and temporal variations of heating degree-days (HDDs) and cooling degree-days (CDDs) are closely related with the temperature field. The spatial distribution of 30-year mean HDDs shows that the higher values locates in the northern part of South Korea while the lower values locates in the southern part. The 30-year mean CDDs shows a more randomized distribution than the HDDs. The changing trends of HDDs and CDDs show a different feature: HDDs have a distinct decreasing trend while CDDs have an insignificant change. The decreasing trends of HDDs are consistent over South Korea and most of stations have experienced the statistically significant change. As significant changing areas of HDDs are much broader than those of annual mean temperature, HDDs can be more useful than annual mean temperature to detect the climate change impact on a regional level. In other words, an insignificant change on the mean temperature field can induce the significant change of thermal climatology in a region. The temporal pattern of climatic departure index (CDI) for South Korea HDDs series shows a general decreasing, but a sharp increase during recent years. The drastic decrease of HDDs induces higher CDI indicating larger variability among stations. However, the decrease of South Korea HDDs series cannot totally attribute to the global warming due to urban effects. By the early 1980s, there were no big differences of HDDs between urban and rural series, but later the differences are getting larger. This was expected to be with the intensification of urbanization in South Korea. However, still there is a decreasing trend of HDDs for rural stations.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.

Effects of Cooling Water System of a Power Plant on Marine Organisms II. Effects on Benthic Organisms (화력발전소 냉각계통이 해양생물에 미치는 영향 II. 저서생물에 미치는 영향)

  • YI Soon Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.5
    • /
    • pp.391-407
    • /
    • 1987
  • To understand the effects of the cooling water system of the power plant on the succession of sessile zoobenthos, a series of experiments were carried out at the cooling water system of Samchonpo Power Plant from Hay 1985 to May 1986. The lowest species diversity of the zoobenthos was observed at the discharge canal. This is probably caused by both increased velocity and temperature of circulating water. It is also noticeable that species composition of the zoobenthos, to a certain degree, was affected due to the impingement of meroplankton during the entrainment process. While the number of species attached on the experimental substrata installed in the thermally altered area is smaller than that in the intake canal, the biomass is increased as the increased temperature eliminates some species and in turn stimulates reproduction and growth of the others. It is interesting that relatively high similarity exists between the summer communities in the intake canal and the spring communities in the thermally altered area, and the same relationship is also found between the fall communities in the intake canal and the winter communities in the thermally altered area. Ecological index curves of the zoobenthos of the intake canal follows the fluctuation pattern of the thermally altered area in one or two months of elapsed time, probably due to temperature increase by the inflow of heated water discharged from the power plant.

  • PDF