• 제목/요약/키워드: cooling flows

검색결과 191건 처리시간 0.026초

Heat Transfer Analysis for Endothermic Reacting Fluids

  • Kimura, Hiroyuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.346-357
    • /
    • 2008
  • Endothermic fuels are known as a probable fuel for hypersonic atmospheric flight vehicles and advanced propulsion systems, as well as cryogenic fuels. Especially, from the standpoint of the advanced regenerative cooling use, they are quite useful as a coolant fuel because of their large heat sink due to their chemical decompositions; so-called endothermic cooling effect. However, no heat transfer equations have been proposed taking into account such endothermic reactive behaviors concretely. This paper describes an analytical method for evaluation of the heat transfer rates between endothermic reacting coolant fuel and coolant-side wall in the regenerative cooling passages. Heat transfer mechanism is indicated based on a classical transport-phenomenological approach. A new relational expression of Nusselt number ratio for forcedconvective heat transfer with such endothermic reactions is also proposed by theoretical approaches using some classical hypotheses. Its applicability is assessed provisionally by comparison with confirmed results of heated tube tests for supercritical JP-7 fuel carried out at NASA Lewis Research Center, using its heat sink characteristics evaluated by United Technologies Research Center(UTRC). As a result, it has been suggested that the proposed relational equation is applicable to the evaluation of enhancement of Nusselt numbers due to such reactions in developed turbulent flows such as in the regenerative cooling passages.

  • PDF

과냉각을 동반한 동결과정의 수치해석 (Numerical Analysis for Cooling and Freezing Processes with Subcooling)

  • 윤정인;김재돌;김성규
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.451-462
    • /
    • 1996
  • In this study, which focuses on ice storage, a fundamental study in cooling and solidification was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation considering existence of subcooling and dendritic ice were analyzed numerically by using finite difference method and boundary fixing method. In the mesh, the solid fraction was introduced with adding as a term to the energy conservation equation. A flow in the dendrite was modelled as a flow in a porous medium, and the momentum conservation equation was modified to incorporate resistance forces involved in flows through porous media. A numerical solution of the time dependencies of dendrite area and dense ice front was successfully obtained, and the numerical results were good agreement with experimental results. Based on this methodology, a discussion was made of phenomena and characteristics of cooling and freezing processes under various conditions.

  • PDF

이산화탄소의 초임계 가스냉각 과정의 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental Studies on Heat Transfer and Pressure Drop Characteristics during Gas Cooling Process of Carbon Dioxide in the Supercritical Region)

  • 윤석호;김주혁;김민수
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.538-545
    • /
    • 2004
  • This paper presents the experimental data for the heat transfer and pressure drop characteristics obtained during the gas cooling process of carbon dioxide in a horizontal tube. The tube in which carbon dioxide flows is made of copper with an inner diameter of 7.73 mm. Experiments were conducted for various mass fluxes and inlet pressures of carbon dioxide. Mass fluxes are controlled at 225, 337 and 450 kg/$m^2$s and inlet pressures are adjust-ed from 7.5 to 8.8 ㎫. The experimental results in this study are compared with the existing correlations for the supercritical heat transfer coefficient, which generally under-predict the measured data. Pressure drop data agree very well with those calculated by the Blasius' equation. Based on the experimental data, a new empirical correlation to estimate the near-critical heat transfer coefficients has been developed.

냉각수 공급방식 및 국부적인 물통로의 형상 변화에 따른 냉각수 유동특성 및 연소실 벽면의 냉각효과 (Coolant Flow Characteristics and Cooling Effects in the Cylinder Head with Coolant Flow System and Local Water Passage)

  • 위신환;민영대;이종태
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.32-41
    • /
    • 2003
  • For the countermeasure of expected higher thermal load in miller cycle engine, coolant flows in the cylinder head of base engine with several coolant flow methods and drilled hole passages were measured by using PIV technique. And the cooling effect was evaluated by measurements of wall temperatures according to each coolant flow method. It was found that the series flow system was most suitable among the discussed 3 types of coolant flow methods since it had the best cooling effect in cylinder head by the fastest coolant flow velocity It was also found that for drilled water passage to decrease the large thermal load in exhaust valve bridge, nozzle type is more effective compared with round type of water passage, and its size has to be determined according to the coolant flow pattern and velocity in each cylinder.

터보샤프트 엔진의 배기 이젝터 설계 및 유동해석 (THE DESIGN AND ANALYSIS OF EXHAUST EJECTOR FOR TURBOSHAFT ENGINE)

  • 이창호;김철완
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.97-100
    • /
    • 2006
  • An ejector is designed for the purpose of engine bay cooling and exhaust gas cooling. The primary flow of the ejector is the exhaust gas of the turboshaft engine. The mass flow of secondary flow is calculated by using the approximate analytic equation. For the purpose of verification of approximate method, comparison is made with the results of Navier-Stokes turbulent flow solution. According to the results of CFD, the mixing of two flows is incomplete due to the short length of mixing duct.

  • PDF

유수대류계수에 관한 실험적 연구 (Experimental Study on Coefficient of Flow Convection)

  • 정상은;오태근;양주경;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2000
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structure, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection is developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect in internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. finally a prediction model of the coefficient of flow convection is proposed using experimental results from the developed device. According to the proposed prediction model, the coefficient of flow convection increases with increase in flow velocity and decreases with increase in pipe diameter and thickness. Also, the coefficient of flow convection is largely affected by the type of pipe materials.

  • PDF

정사각 덕트 초임계 상태 이산화탄소 가스 냉각과정 중 2차 유동 특성 측정 연구 (Experimental Study on the Secondary Flow Characteristics of a Supercritical Carbon Dioxide Flow in a Gas Cooling Process Within a Square Duct)

  • 한성호;서정식;김용찬;김민수;최영돈
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.158-165
    • /
    • 2008
  • The carbon dioxide properties change sharply near the critical or pseudo-critical point in the heat transfer processes. The reduction in turbulent, convective heat transfer parameters observed in some supercritical data and in experiments with common gases can be due to property variation, acceleration, buoyancy or combinations of these phenomena, depending on the conditions of the applications. In this study, the measurement for the secondary flow driven by buoyancy was carried out on the supercritical carbon dioxide turbulent flows in the different boundary condition with the constant mass flow rate. The available measuring techniques were used to clarify the behaviour of any supercritical fluid. Laser Doppler Velocimeter (LDV) and a special device was used to measure the secondary velocity and turbulent characteristics of the supercritical flows.

유동 가이드가 열파퍼 플라즈마 챔버의 아크현상 이력에 미치는 영향 (Effects of a Flow Guide on the Arcing History in a Thermal Puffer Plasma Chamber)

  • 이종철;김윤제
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.832-839
    • /
    • 2007
  • The geometry and dimensions of an expansion chamber are decisive factors in thermal puffer plasma chamber designs. Because they together dominate the temperature and speed at which the cooling gas from the chamber flows back through a flow channel to the arcing zone for the successful interruption of fault currents. In this study, we calculated the flow and mass transfer driven by arc plasma, and investigated the effects of a flow guide installed inside a thermal puffer plasma chamber. It is found that the existing cold gas of the chamber mixes with hot gases entrained from the arcing zone and is subjected to compression due to pressure build-up in the chamber. The pressure build-up with the flow guide is larger than that without due to a vortex which rotates clockwise around the chamber center. By the reverse pressure gradient, the mixing gas of the chamber flows back out for cooling down the residual plasma near current zero. In the case with the flow guide, the temperature just before current zero is lower than that without, and the Cu concentration with high electrical conductivity is also less than that without the flow guide.

형상이 다른 수평 원형 전열관의 응축 성능에 관한 연구 (A Study on the Condensation Performance for the Horizontal Heat Transfer Tubes with Various Fin Attached)

  • 한규일;박종운
    • 수산해양교육연구
    • /
    • 제4권1호
    • /
    • pp.47-61
    • /
    • 1992
  • An experimental study was carried out to investigate the condensation performance for the horizontal cylindrical heat transfer tube with various fin attached using R-11 vapor. The heat transfer tube used in this study was supplied by SUNG HYUNG METAL CO., LTD. Four different types of heat transfer tubes (plain tube, SH-CYR tube, thermocor tube and thermoexcel tube) were used. Each tube was surrounded by circular acrylate tube, and R-11 gas heated by boiler flows into the acrylate tube. Cooling water counter-flows in heat transfer tubes. Heat transfer coefficient of the plain tube from measured data was compared with those of three other tubes. The results are summarized as follows: 1. As the cooling water temperature decreased, the liquid film of R-11 turned to droplet drop on the top surface of the horizontal tube. 2. Heat transfer coefficient calculated theoretically was higher than that obtained from the experimental data. 3. As far as the condensation concerns the thermocor tube is the highest, the SH-CYR tube is the second, and the thermoexcel tube is the third excluding the plain tube.

  • PDF

An Isothermal Mganetohydrodynamic Code and Its Application to the Parker Instability

  • KIM JONGSOO;RYU DONGSU;JONES T. W.;HONG S. S.
    • 천문학회지
    • /
    • 제34권4호
    • /
    • pp.281-283
    • /
    • 2001
  • As a companion to an adiabatic version developed by Ryu and his coworkers, we have built an isothermal magnetohydrodynamic code for astrophysical flows. It is suited for the dynamical simulations of flows where cooling timescale is much shorter than dynamical timescale, as well as for turbulence and dynamo simulations in which detailed energetics are unimportant. Since a simple isothermal equation of state substitutes the energy conservation equation, the numerical schemes for isothermal flows are simpler (no contact discontinuity) than those for adiabatic flows and the resulting code is faster. Tests for shock tubes and Alfven wave decay have shown that our isothermal code has not only a good shock capturing ability, but also numerical dissipation smaller than its adiabatic analogue. As a real astrophysical application of the code, we have simulated the nonlinear three-dimensional evolution of the Parker instability. A factor of two enhancement in vertical column density has been achieved at most, and the main structures formed are sheet-like and aligned with the mean field direction. We conclude that the Parker instability alone is not a viable formation mechanism of the giant molecular clouds.

  • PDF