• Title/Summary/Keyword: cooling flows

Search Result 191, Processing Time 0.026 seconds

THERMAL CONDUCTION IN MAGNETIZED TURBULENT GAS

  • CHO JUNGYEON;LAZARIAN A.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.557-562
    • /
    • 2004
  • We discuss diffusion of particles in turbulent flows. In hydrodynamic turbulence, it is well known that distance between two particles imbedded in a turbulent flow exhibits a random walk behavior. The corresponding diffusion coefficient is ${\~}$ ${\upsilon}_{inj}{\iota}_{turb}$, where ${\upsilon}_{inj}$ is the amplitude of the turbulent velocity and ${\iota}_{turb}$ is the scale of the turbulent motions. It Is not clear whether or not we can use a similar expression for magnetohydrodynamic turbulence. However, numerical simulations show that mixing motions perpendicular to the local magnetic field are, up to high degree, hydrodynamical. This suggests that turbulent heat transport in magnetized turbulent fluid should be similar to that in non-magnetized one, which should have a diffusion coefficient ${\upsilon}_{inj}{\iota}_{turb}$. We review numerical simulations that support this conclusion. The application of this idea to thermal conductivity in clusters of galaxies shows that this mechanism may dominate the diffusion of heat and may be efficient enough to prevent cooling flow formation when turbulence is vigorous.

A study of Energy use Impacts by SHGCs of Windows in Detached House (주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구)

  • Park, Yool;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.189-196
    • /
    • 2010
  • U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

Effect of Materials on Streaming Electrification in Transformer (유동대전(流動帶電)에 미치는 변압기(變壓器) 재질(材質)의 영향(影響))

  • Kweon, Dong-Jin;Kang, Chang-Gu;Kwak, Hee-Ro;Kim, Jae-Chul;Lee, Deok-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.170-172
    • /
    • 1990
  • In a large power transformer, an insulating oil is forced to circulate for cooling the heat generated by the losses within the windings and core. When oil flows and rubs against various materials, including insulating paper and steel, electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the polarity and the streaming electrification of the various materials which are used in transformer. As a result of this study, it is confirmed that the leakage current on the solid material, such as paper, is charged negative. On the other hand, the solid material, such as steel, is positively charged.

  • PDF

Computational study on flows by propeller fans with different blades (프로펠러형 팬의 날개형상에 따른 전산 해석적 연구)

  • Lee J. M.;Kim J. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.163-169
    • /
    • 2000
  • Design and developments of a propeller fan for a cooling tower have been accomplished by both numerical prediction of performance and experimental validation with a wind tunnel, Main interest lies on blade geometry of a fan for optimal design of aerodynamic performance. The present methodology for numerical estimation is commercial program, Fine/Turbo, which gives us engineering information such as flow details near the blades and flow rate of it. The numerical results are compared with precise experimental output and show good agreement. Also new proposed model of a blade with the program show improved performance relative to present running model in market.

  • PDF

Numerical study on fluid flow by hydrodynamic loads in reactor internals

  • Kim, Da-Hye;Chang, Yoon-Suk;Jhung, Myung-Jo
    • Structural Engineering and Mechanics
    • /
    • v.51 no.6
    • /
    • pp.1005-1016
    • /
    • 2014
  • Roles of reactor internals are to support nuclear fuel, provide insertion and withdrawal channels of nuclear fuel control rods, and carry out core cooling. In case of functional loss of the reactor internals, it may lead to severe accidents caused by damage of nuclear fuel assembly and deterioration of reactor vessel due to attack of fallen out parts. The present study is to examine fluid flows in reactor internals subjected to hydrodynamic loads. In this context, an integrated model was developed and applied to two kinds of numerical analyses; one is to analyze periodic loading effect caused by pump pulsation and the other is to analyze random loading effect employing different turbulent models. Acoustic pressure distributions and flow velocity as well as pressure and temperature fields were calculated and compared to establish appropriate analysis techniques.

RESPONSES OF THE TRANSITION REGION TO DOWNWARD AND UPWARD FLOWS

  • YUN H. S.;CHAE J.-C.;POLAN A. I.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.339-340
    • /
    • 1996
  • In the present study we examine physical characteristics of a thin and rigid magnetic flux tube with a steady flow inside, which is embedded vertically upward in the solar atmosphere. We found from this study that (1) The downward material flow gives rise to a dominant heating in the flux tube which works with the conductive heating in the same direction. However, the upflow flow creates a dominant cooling which works against the conductive heating, resulting in a steeper temperature gradient with a shallower transition region. (2) Since the thickness of the transition region determines the material content in the transition region, a broader transition region of the downflow tube produces a larger differential measure.

  • PDF

Forced Convection in a Flow Channel with Multiple Obstacles (다수의 장애물을 가진 유동채널에서의 강제 대류에 관한 연구)

  • Nam, Pyung-Woo;Cho, Sung-Hwan
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.62-69
    • /
    • 1989
  • This analysis is to investigate the influence of inflow angle when cooling air flows into PC (Printed Circuit) board channels. Flow between PC board channels with heat generating blocks is assumed laminar, incompressible, two-dimensional. Geometric parameters (block spacing (S), block height (H), block width (W) and channel height (L)) are held fixed. Inflow angle variations are $-10^{\circ},\;0^{\circ},\;10^{\circ}$, where uniform heat flux per unit axial length Q (W/m) from heated block surfaces is generated. The governing equations for velocity and temperature are solved by SIMPLE (Semi-Implicit Method Pressure for Linked Equation) algorithm. Nusselt number on each block surfaces is analyzed after a numerical calculation result. The result shows that the assumption on parallel inflow (inflow angle to channel, $0^{\circ}$) to PC board channels can be used without large error even when inflow' angle is varied.

  • PDF

Performance characterization of liquid desiccant system with extended surface (확장표면을 적용한 액체식 제습시스템의 성능특성에 관한 연구)

  • Jang, Young-Soo;Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.639-644
    • /
    • 2009
  • This study presents the new idea of liquid desiccant system with extended surface to reduce the system size. The extended surface is inserted between vertical cooling/heating tubes to increase the mass transfer area, and the liquid desiccant flows through the tube wall and the extended surface. Mathematical models for heat and mass transfer between liquid desiccant and air stream at tube wall and extended surface are provided. Dimensionless design parameters governing heat and mass transfer phenomena around the tube and the extended surface are identifier, and dimensionless operating parameters depicting system operating condition including flow rate ratio between dehumidification/regeneration processes, and mass flow rate ratio between air stream and liquid desiccant are explained. The effects of the parameters on system performance are summarized.

  • PDF

MULTI-SCALE THERMAL-HYDRAULIC ANALYSIS OF PWRS USING THE CUPID CODE

  • Yoon, Han Young;Cho, Hyoung Kyu;Lee, Jae Ryong;Park, Ik Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.831-846
    • /
    • 2012
  • KAERI has developed a two-phase CFD code, CUPID, for a refined calculation of transient two-phase flows related to nuclear reactor thermal hydraulics, and its numerical models have been verified in previous studies. In this paper, the CUPID code is validated against experiments on the downcomer boiling and moderator flow in a Calandria vessel. Physical models relevant to the validation are discussed. Thereafter, multi-scale thermal hydraulic analyses using the CUPID code are introduced. At first, a component-scale calculation for the passive condensate cooling tank (PCCT) of the PASCAL experiment is linked to the CFD-scale calculation for local boiling heat transfer outside the heat exchanger tube. Next, the Rossendorf coolant mixing (ROCOM) test is analyzed by using the CUPID code, which is implicitly coupled with a system-scale code, MARS.

Application of turbulent model to characteristics of heat transfer in impinging jet flow with pulsed inlet (입구유동 가진이 있는 충돌제트 유동의 유동 및 열전달 변화에 대한 난류모델 적용)

  • Kwon, Dong-Ho;Kim, Hee-Yougn;Park, Tae-Seon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.593-596
    • /
    • 2008
  • Because of good performance of heat transfer characteristics, impinging jets are widely used in many industries for cooling or heating. And the present num erical studies attempt to show the effects of impinging jet. This paper considers the application of the turbulent models to impinging jet flow with pulsed inlet. It is assumed two-dimensional turbulent flows. The jet Reynolds num ber is set at 23,000 and the distance from the exit of the nozzle to the plate is 3 times larger than the diam eter of the nozzle. The influence of the Strouhal num ber(pulsation frequency) on Nusselt number at the impinging region is investigated. Strouhal numbers are ranged 0.0 to 0.5 and the forcing amplitudes are 1%,5%,9% of mean inlet velocity. In this study, the Nusselt number at the impinging region is sensitive to the pulsation frequency. Heat transfer coefficient strongly increase at Strouhal num ber of 0.4.

  • PDF