• Title/Summary/Keyword: cooling capacity difference

Search Result 70, Processing Time 0.039 seconds

A Study on the Characteristics of Heat Treated ERW Weld Seam and the Technology of Seam Annealing (고장력 강재의 전기저항 용접부 열처리 특성 및 기술에 대한 연구)

    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.133-144
    • /
    • 1999
  • To fine seam annealer capacity of through thickness seam annealing in terms of through thickness microstructure change with increased toughness and elongation leaving heat trace on it, high strength steel pipes of ERW with different thickness were tested in different seam annealing temperature measured on the outer surface of pipes. Annealing temperature and microstructure of the weld seam were changed through applied seam annealing condition. Toughness and tensile test with hardness and microstructure analysis were done on the annealed weld seam to fine its characteristics as a primary step and annealing characteristics according to different seam annealing condition. Through a study of annealed ERW weld seam characteristics and seam annealing technology, amount of electric power should apply in decreased manner to arranged inductors of annealer in the order of 1st, 2nd, 3rd, so on for proper seam annealing. For example of 15.4mm thick and 610mm outside diameter pipe, applied power for proper seam annealing is 600 -650kw at 1st inductor, 450 - 500kw at 2nd inductor, 200-250 kw at 3rd inductor of annealer during 10 - 12M/minute moving speed of pipe. Also, the penetration depth of heat trace along the thickness direction of weld during seam annealing can be estimated through the equation 17mm/kv$\times$voltage(kv) with the microstructure and hardness analysis of thick weld seam as well as study of seam annealing and comparison of cooling condition to CCT diagram of low carbon high strength steel. From this result, the difference between the technological applicability of full annealing condition based on phase diagram and full penetration of heat trace based on CCT diagram along the thickness of weld seam is discussed.

  • PDF

Research on Heat-Sink of 40Watt LED Lighting using Peltier Module (펠티어 소자를 이용한 40[W]급 LED 조명기구의 방열에 관한 연구)

  • Eo, Ik-Soo;Yang, Hae-Sool;Choi, Se-Ill;HwangBo, Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.733-737
    • /
    • 2007
  • The object of this paper is to propose a method to solve resulting heat in using numerous modulized watt-class LEDs in MCPCB as lighting device. To use LED for lighting, the chip needs to have a large capacity, resulting in extra heat in P-N connection area. To solve this problem, a Pottier Module, heat-sink panel and a fan was installed to measure variations in the temperature. Additionally, temperature variation characteristics were observed according to the heat conductor panel connecting cooling module and heat-sink panel, insulator and thermal grease. As a result, the type and amount of heat-sink panel was the most important facto. The fan would effect the temperature by max. $18[^{\circ}C]$ while other materials affected the temperature by $2{\sim}3[^{\circ}C]$, showing significant difference.

  • PDF

The Effects of Inclined Foil Shape on Flow Characteristics in Air Foil Thrust Bearing Using CFD (에어 포일 스러스트 베어링의 탑포일 경사면 형상이 유동특성에 미치는 영향에 대한 수치해석 연구)

  • Baek, GeonWoong;Joo, Won-Gu;Mun, Hyeong Wook;Hwang, Sunghyen;Jeong, Sung-Yun;Park, Jung-Koo
    • Tribology and Lubricants
    • /
    • v.37 no.4
    • /
    • pp.117-124
    • /
    • 2021
  • In this study, we perform a 3D CFD conjugate analysis according to the shape of the foil ramp of the air foil thrust bearing, analyze the flow characteristics inside the bearing, and compare the results corresponding to the two shapes. Air has a lower viscosity than lubricating oil. Therefore, the thrust runner of the bearing must rotate at high speed to support the load. The gap between thrust runner and foil is significantly smaller than that of the oil bearing. Hence, it is crucial to analyze the complex flow characteristics inside the bearing to predict the complex flow inside the bearing and performance of the bearing. In addition, flow characteristics may appear differently depending on the ramp shape of the bearing foil, which may affect bearing performance. In this study, we numerically analyze the main flow path of air flowing into the bearing and the secondary flow path used for cooling the bearing using the commercial CFD software ANSYS CFX and compare the flow characteristics for straight and curved foil ramp shapes. Notably, there is a difference in the speed of the flowing air according to the shape of the ramp, which affects the bearing performance.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.

Comparison of Meat Quality Characteristics of Two Different Three-way Crossbred Pigs (Landrace × Yorkshire × Duroc and Landrace × Yorkshire × Woori black pig) (두 가지 삼원교잡종 (랜드레이스 × 요크셔 × 두록 및 랜드레이스 × 요크셔 × 우리흑돈)의 육질특성 비교)

  • Kim, Jeong A;Cho, Eun Seok;Lee, Mi-Jin;Jeong, Yong Dae;Choi, Yo Han;Cho, Kyu Ho;Chung, Hak Jae;Baek, Sun Young;Kim, Young Sin;Sa, Soo Jin;Hong, Jun Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.195-202
    • /
    • 2019
  • This study was undertaken to investigate whether the local Woori black pigs could replace Duroc as the terminal sire in order to reduce foreign currency outgoings. This study compared the physicochemical properties of pork loins in two cultivars of three-way crossbred pigs: Landrace ${\times}$ Yorkshire ${\times}$ Duroc (LYD) and Landrace ${\times}$ Yorkshire ${\times}$ Woori black pig (LYW). A total of 119 pigs (59 LYD and 60 LYW) aged 180 days were used in the experiment. After 24 hours of cooling, pork loins were assessed for their physicochemical traits, meat color, fatty acid and sensory evaluation. The moisture content and water holding capacity showed no significant difference between the two cultivars. Fat content and cooking loss were significantly higher in LYW than in LYD (p<0.05), whereas shear force and pH were significantly lower in LYW than LYD (p<0.05). Redness ($a^*$), yellowness ($b^*$), and stearic acid (C18: 0) content were also significantly higher in LYW than in LYD (p<0.05). Sensory evaluation revealed significantly higher meat color and flavor in LYW than LYD (p<0.05). Taken together, these results indicate that certain physicochemical qualities are improved in the LYW cultivar, as compared to LYD. Therefore, Woori black pig (W) has the potential to be substituted for Duroc, a breeding pig used currently.

Comparison of meat quality characteristics of Yorkshire, Duroc, Pietrain and Crossbred Pigs (Duroc × Pietrain) (요크셔, 두록, 피어트레인 및 교잡동(두록 × 피어트레인)의 육질특성 비교)

  • Lee, Mi Jin;Cho, Eun seok;Choi, Tae Jeong;Kim, Yong Min;Kim, Young Sin;Jeong, Yong Dae;Kim, Nam Hyung;Cho, Kyu Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.116-125
    • /
    • 2018
  • This study was carried out physicochemical and sensory evaluation to compare the quality characteristics of pork loins from Yorkshire, Duroc, Pietrain, and Duroc ${\times}$ Pietrain (DP). A total of 79 pigs from Yorkshire(22), Duroc(22), Pietrain(17), and DP(18) was used for the experiment. After 24 hours of cooling, pork loins were gathered and vacuum-packed from left carcasses and then the physicochemical traits and sensory evaluation were conducted. The pH of the loins from breed Pietrain was lower than those of the other breeds (p<0.01). While the moisture content of loins was higher in Pietrain than in the other breeds (p<0.01). The fat content of loins was higher in Duroc and DP than in the other breeds and lower in Pietrain than in the other breeds (p<0.01). Pietrain loins had the lowest drip loss (p<0.01) and the highest water holding capacity (p<0.01). There were no significant differences in the cooking loss and shear force of the loins among 4 breeds (p>0.05). There was a significant difference in the CIE color L*, a* and b* values of the loins from 4 breeds (p<0.01). Sensory scores of the loins were ranked lower in Pietrain in overall. The results of this study indicate that meat quality could be altered according to the breeds.

Establishment of Bovine Ovum Bank : I. Full Term Development of Vitrified In Vitro Matured Hanwoo (Korean Cattle) Oocytes by Minimum Volume Cooling (UC) Method (소 난자 은행 설립 : I. MVC 방법으로 초자화 동결된 한우 미성숙 난자의 개체 발생능 조사)

  • Kim, E.Y.;Kim, D.I.;Rhee, M.G.;Weon, Y.S.;Nam, H.K.;Lee, K.S.;Park, S.Y.;Park, E.M.;Yoon, J.Y.;Heo, Y.T.;Cho, H.J.;Park, S.P.;Chung, K.S.;Lim, J.H.
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • This study was to test whether in vitro matured Hanwoo oocytes can be successfully cryopreserved by a new vitrification procedure using MVC method. For the vitrification, oocytes were pretreated in 10% ethylene glycol (EG10) for 5~10 min, exposed in EG30 for 30 sec, each oocyte was individually put on the inner wall of 0.25 $m\ell$ straw, and then straws were directly plunged into L$N_2$. Thawing was taken by 4-step procedures 〔1.0 M sucrose (MS), 0.5 MS, 0.25 MS, and 0.125 MS〕 at 37$^{\circ}C$. In vitro developmental capacity (survival, cleavage ($\geq$2-cell) and blastocyst rates) in vitrified group was no significant difference compared to that in other treatment groups (exposed; 100.0, 74.4, 32.3% and control; 100.0, 78.3, 36.3%): high mean percentage of oocytes (91.2%) was survived, 69.4% of them were cleaved and 27.9% of cleaved embryos were developed to blastocyst. Especially, after transfer of in vitro developed embryos in vitrified group, four of six recipient animals were pregnant and three of them were ongoing-pregnant by manual palpation at 250 days after transfer. This result demonstrates that MVC method is very appropriate freezing method for the Hanwoo in vitro matured oocytes and that ovum bank can be maintained efficiently by MVC cryopreservation method.

  • PDF

Study of East Asia Climate Change for the Last Glacial Maximum Using Numerical Model (수치모델을 이용한 Last Glacial Maximum의 동아시아 기후변화 연구)

  • Kim, Seong-Joong;Park, Yoo-Min;Lee, Bang-Yong;Choi, Tae-Jin;Yoon, Young-Jun;Suk, Bong-Chool
    • The Korean Journal of Quaternary Research
    • /
    • v.20 no.1 s.26
    • /
    • pp.51-66
    • /
    • 2006
  • The climate of the last glacial maximum (LGM) in northeast Asia is simulated with an atmospheric general circulation model of NCAR CCM3 at spectral truncation of T170, corresponding to a grid cell size of roughly 75 km. Modern climate is simulated by a prescribed sea surface temperature and sea ice provided from NCAR, and contemporary atmospheric CO2, topography, and orbital parameters, while LGM simulation was forced with the reconstructed CLIMAP sea surface temperatures, sea ice distribution, ice sheet topography, reduced $CO_2$, and orbital parameters. Under LGM conditions, surface temperature is markedly reduced in winter by more than $18^{\circ}C$ in the Korean west sea and continental margin of the Korean east sea, where the ocean exposed to land in the LGM, whereas in these areas surface temperature is warmer than present in summer by up to $2^{\circ}C$. This is due to the difference in heat capacity between ocean and land. Overall, in the LGM surface is cooled by $4{\sim}6^{\circ}C$ in northeast Asia land and by $7.1^{\circ}C$ in the entire area. An analysis of surface heat fluxes show that the surface cooling is due to the increase in outgoing longwave radiation associated with the reduced $CO_2$ concentration. The reduction in surface temperature leads to a weakening of the hydrological cycle. In winter, precipitation decreases largely in the southeastern part of Asia by about $1{\sim}4\;mm/day$, while in summer a larger reduction is found over China. Overall, annual-mean precipitation decreases by about 50% in the LGM. In northeast Asia, evaporation is also overall reduced in the LGM, but the reduction of precipitation is larger, eventually leading to a drier climate. The drier LGM climate simulated in this study is consistent with proxy evidence compiled in other areas. Overall, the high-resolution model captures the climate features reasonably well under global domain.

  • PDF