• 제목/요약/키워드: cooling capacity

Search Result 835, Processing Time 0.028 seconds

Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir (저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실)

  • Bhang, Byeong Gwan;Woo, Sung Cheol;Lee, Wonbin;Choi, Jin Ho;Shin, SeungWook;Lee, ChulSung;Park, MiLan;Won, Changsub;Ahn, HyungKeun
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.

Study on the Lubricant Flow Behaviors in the Wet Clutch Pack System of Dual Clutch Transmission (습식 DCT(Dual Clutch Transmission) 클러치 팩 내부에서의 체결 동작에 따른 변속기유 거동 연구)

  • Kim, WooJung;Lee, SangHo;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.85-91
    • /
    • 2017
  • This work studies the flow behaviors in the gap between the friction pad and separator in wet-clutch systems. The fluid volume of the lubricant is modeled using the entire system of wet-clutch pack of a dual clutch transmission that has larger outer radius of odd gear shifts and smaller inner radius of even gear shifts. Flow behaviors in the gap of the clutch pad are computed using the gear shift modes that consider the real relative velocities between the friction pad and separator. Flow behaviors in the gap of the disengaged clutch pad are mainly investigated for the wet-clutch system, whereas the engaged clutch pad is modeled with no fluid rate through the contacting surfaces. The developed hydrodynamic fluid pressures and velocity fields in the clutch pad gap are computed to obtain the relevant information for managing flow rates in wet-clutch packs under dual operating conditions during gear shifts. These hydrodynamic pressures and velocity fields are compared on the basis of each gear level and gap location, which is necessary to determine the effects of groove patterns on the friction pad. Shear stresses in the gap locations are also computed on the basis of the gear level for the inner and outer clutch pads. The computed results are compared and used for the design of cooling capacity against frictional heat generation in wet-clutch pack systems.

Applicability Assessment of Acid Treated Red Mud as Adsorbent Material for Removal of Six-valent Chromium from Seawater (해수에서 6가 크롬 제거를 위한 흡착제로서의 산처리 적니 적용성 검토)

  • Kang, Ku;Um, Byung-Hwan;Kim, Young-Kee;Park, Seong-Jik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.5
    • /
    • pp.17-23
    • /
    • 2013
  • Six-valent chromium ($Cr^{6+}$) is a highly toxic pollutant, supplied in a variety of industrial activities such as leather tanning, cooling tower blowdown, and plating. Herein, we investigated the removal of $Cr^{6+}$ from aqueous phase using low-cost adsorbents. Steel slag, montmorillonite, illite, kaolinite, red mud, and acid treated red mud with 0.5, 1.0, and 2.0 M HCl were used as adsorbent for the removal of $Cr^{6+}$ and the results showed that acid treated red mud with 2.0 M HCl (ATRM-2.0 M) had higher adsorption capacity of $Cr^{6+}$ than other adsorbents used. Accordingly, $Cr^{6+}$ removal by ATRM-2.0 M were studied in a batch system with respect to changes in initial concentration of $Cr^{6+}$, initial solution pH, adsorbent dose, adsorbent mixture, and seawater. Equilibrium sorption data were described well by Freundlich isotherm model. The influence of initial solution pH on $Cr^{6+}$ adsorption was insignificant. The use of the ATRM-2.0 M alone was more effective than mixing it with other adsorbents including red mud, zeolite, oyster shell, lime stone, and montmorillonite for the removal of $Cr^{6+}$. The $Cr^{6+}$ removal of the ATRM-2.0 M was slightly less in seawater than deionized water, resulting from the presence of anions in seawater competing for the favorable adsorption site on the surface of ATRM-2.0 M. It was concluded that the ATRM-2.0 M can be used as a potential adsorbent for the removal of $Cr^{6+}$ from the aqueous solutions.

Establishment of Bovine Ovum Bank : I. Full Term Development of Vitrified Hanwoo (Korean Cattle) In Vitro Matured Oocytes by Minimum Volume Cooling (MVC) Method

  • 김은영;김덕임;이문걸;이종우;이금실;박세영;박은미;윤지연;허영태
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.5-5
    • /
    • 2001
  • This study was to test whether Hanwoo in vitro matured oocytes can be successfully cryopreserved by a new vitrification procedure using MVC method. For the vitrification, oocytes were pretreated in 10% ethylene glycol (EG10) for 5-10 min, exposed in EG30 for 30 sec, each oocytes were individually put on the inner wall of 0.25 $m\ell$ straw, and then straws were directly plunged into L$N_2$. Thawing was taken by 4-step procedures [1.0 Msucrose (MS), 0.5 MS, 0.25 MS, and 0.125 MS] at 37$^{\circ}C$. In vitro developmental capacity (survival, cleavage ($\geq$2-cell) and blastocyst rates) in vitrified group was no significant difference compared to that in other treatment groups (exposed; 100.0, 74.4, 32.3% and control; 100.0, 78.3, 36.3%): high mean percentage of oocytes (91.2%) was survived, 69.4% of them were cleaved and 27.9% of cleaved embryos were developed to blastocyst. Especially, after transfer of in vitro developed embryos in vitrified group, four of six recipient animals were found to pregnant and three of them were ongoing pregnant by manual palpation at 250 days after transfer. However, among them, two healthy female calves (23 and 25kg) were born. This result demonstrates that MVC method is very appropriate freezing method for the Hanwoo in vitro matured oocytes and that ovum bank can be maintained efficiently by MVC cryopreservation method.

  • PDF

The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling (냉매 과냉각을 이용한 열펌프 시스템의 성능 특성)

  • Roh, Geon-Sang;Son, Chan-Ghyo
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.4
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

Comparison of Physicochemical Prolperties of Cowpea and Mung Bean Starches (동부와 녹두전분의 이화학적 특성비교)

  • 윤계순
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 1989
  • Mung bean starch gel (Mook) and gel made from starch of cowpea are similar properties in texture. In order to elucidate the similarity between these two starch gels, some physicochemical properties of cowpea starch were compared with those of mung bean starch. Water bildings capacity of cowpea starch (183.6%) was a little low than that of mung bean starch (184.2%). The solobility, swelling power and optical transmitance of the cowpea starch showed a smiliar pattern to mung bean starch, but cowpea starch had a little lower solubility than mung bean starch. Amylogram of mung bean strach (4, 5, 6, 7%) shoved no peak viscosity but cowpea starch (4, 5, 6%) showed peak viscosity and both starches showed high viscosities when cooling. Cowpea and mung bean starches had the blue value of 0.41 and 0.47, the alkali number of 8.4 and 8.0, the amylose content of 30.5 and 32.1%, the molecular weight of amylose of 30,000 adn 29,258 and glucose unit per segment of amylopectin of 27.6 and 26.8 respectively. The shape of cowpea and mung bean strach granules were round and elliptical, and the mean vlalue of major axis, minor axis and the ratio of these were 20.7 and 21.8 ${\mu}{\textrm}{m}$, 14.6 and 14.4 ${\mu}{\textrm}{m}$ and 1.42 and 1.51, respectively. The extent of retrogradation determined by the glucoamylase digestion method and syneresis showed that cowpea starch gel was larger than that syneresis showed than cowpea starch gel was larger than that of mung bean starch gel. The redults of X-ray diffraction studies showed A pattern for two starches, Diffraction peak of gels disappeared with gelatinization of starches but that of two starch gels storaged for 2 days at 5$^{\circ}C$ showed a similar patterm.

  • PDF

Design of a Cryogenic Turbo Expander Drive Shaft for 300 W Class Brayton Refrigerators (300 W급 브레이튼 냉동기용 극저온 터보 팽창기 구동축 설계)

  • Kim, Manryeol;Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.129-135
    • /
    • 2016
  • There have been many types of development and commercialization efforts for superconducting power applications with the continuous development of High Temperature Superconducting (HTS) conductors. In particular, HTS power cables are going to be commercialized in real power grids. A cryogenic refrigeration system should be used to keep it below 77 K, and its required cooling capacity continuously increases as the unit length of the HTS power cable increases. Among the many kinds of cryogenic refrigerator, a reverse Brayton refrigerator that uses turbo expanders is a promising refrigerator due to its efficiency and reliability. Among the various components in refrigerators, the cryogenic turbo-expander is the most important part for increasing efficiency and assuring reliability. The design of a 300 W class turbo-expander is described in this paper prior to the development of a 10 kW class turbo expander, which is the required capability for the commercialization of a HTS power cable. The impeller shape and rotation speed are determined based on the cycle analysis. The Eigen frequency and harmonic analysis are conducted with gas bearings at cryogenic temperatures to determine the operational stability.

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.

Block Smart Rack Technology Development for Increased Efficiency (효율성 증가를 위한 블록 단위 스마트 랙 기술 개발)

  • Tae, Hyo-Sik;Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Data center, not only the development of globally of cloud-based IT solutions, As the big data, education, use of development electronic equipment of communication means is increased, Demand of domestic and international data center has increased steadily. Due to the increase of data center demand, heat generation of server rack due to the development of IT equipment is also increasing continuously. Calculating heat value of the data center, because more than 99% of the power usage of IT server is converted into heat, the calorific value as the size and capacity of the server is larger will increase. In this paper, to center the cooling system of air-cooled, and research and development of air conditioning systems for energy reduction of data center, through performance analysis and simulation, it has been analyzed that there is energy savings.

A Study on the Improvement of Plastic Boat Manufacturing Process Using TOC & Statistical Analysis (TOC와 통계적 분석에 의한 플라스틱보트 제조공정 개선에 관한 연구)

  • Yoon, Gun-Gu;Kim, Tae-Gu;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.130-139
    • /
    • 2016
  • The purpose of this paper is to analyze the problems and the sources of defective products and draw improvement plans in a small plastic boat manufacturing process using TOC (Theory Of Constraints) and statistical analysis. TOC is a methodology to present a scheme for optimization of production process by finding the CCR (Capacity Constraints Resource) in the organization or the all production process through the concentration improvement activity. In this paper, we found and reformed constraints and bottlenecks in plastic boat manufacturing process in the target company for less defect ratio and production cost by applying DBR (Drum, Buffer, Rope) scheduling. And we set the threshold values for the critical process variables using statistical analysis. The result can be summarized as follows. First, CCRs in inventory control, material mix, and oven setting were found and solutions were suggested by applying DBR method. Second, the logical thinking process was utilized to find core conflict factors and draw solutions. Third, to specify the solution plan, experiment data were statistically analyzed. Data were collected from the daily journal addressing the details of 96 products such as temperature, humidity, duration and temperature of heating process, rotation speed, duration time of cooling, and the temperature of removal process. Basic statistics and logistic regression analysis were conducted with the defection as the dependent variable. Finally, critical values for major processes were proposed based on the analysis. This paper has a practical importance in contribution to the quality level of the target company through theoretical approach, TOC, and statistical analysis. However, limited number of data might depreciate the significance of the analysis and therefore it will be interesting further research direction to specify the significant manufacturing conditions across different products and processes.