• 제목/요약/키워드: cooler

검색결과 693건 처리시간 0.025초

인버터 타입 오일냉각기의 온도제어 특성에 관한 연구 (Characteristics of Temperature Control in the Inverter Type Oil Coolers)

  • 이상호;이찬홍;박천홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

Synchronous Linear Motor의 구조변경에 의한 열특성에 개선 (Improvement of the Thermal Characteristics of Synchronous Linear Motors through Structure Change)

  • 은인웅;이춘만;정원지;최영휴
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.367-370
    • /
    • 1997
  • Linear motors can drive a linear motion without intermediate gears, screws or crank shafts. Linear motors can successfully replace ball lead screw in machine tools because they have a high velocity, acceleration and good positioning accuracy. On the other hand, linear motors emit large amounts of heat and have low efficiency. In this paper, the thermal behavior of a synchronous linear motor with high velocity and force is analyzed. To improve the thermal characteristics of the linear motor, structure of linear motor and cooler is changed. Some effects of an integrated cooler, an U-cooler and a thermal symmetrical cooler are presented.

  • PDF

A Study on High Precision Temperature Control of an Oil Cooler for Machine Tools Using Hot-gas Bypass Method

  • Jung, Young-Mi;Byun, Jong-Yeong;Yoon, Jung-In;Jeong, Seok-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.1003-1011
    • /
    • 2009
  • This study aims at precise control of oil outlet temperature in the oil cooler system of machine tools for enhancement of working speed and processing accuracy. PID control logic is adopted to obtain desired oil outlet temperature of the oil cooler system with hot-gas bypass method. We showed that the gains of PID controller could be easily determined by using gain tuning methods to get the gain of PID controller without any mathematical model. We also investigated various gain tuning methods to design the gains of PID and compared each control performance for selecting the optimal tuning method on the hot gas bypass method through experiments. Moreover, we confirmed excellent control performance with proposed PI controller gain even though disturbances were abruptly added to the experimental system.

재생기 및 냉각기가 VM열펌프의 냉방성능에 미치는 영향 (Effects of regenerator and cooler on the cooling performance of a vuilleumier cycle heat pump)

  • 이건태;강병하;유호선;이재헌
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.333-342
    • /
    • 1997
  • An experimental study has been carried out to investigate the effects of the combination of the different wire mesh number in a regenerator and the tube number in a cooler on the cooling performance of a Vuilleumier cycle heat pump. Effects of operating conditions, such as charging pressure, operating speed, and heat input, on the cooling performance are also studied. The experimental results obtained indicate that the cooling performance could be improved with the proper combination of different wire meshes in a regenerator. More tubes in a cooler are desirable for better cooling performance. It is also found that the cooling capacity is enhanced, whereas COP is reduced with an increase in the heater tube temperature and the revolution speed. Both the cooling capacity and COP are incereased with a higher charging pressure.

  • PDF

GA를 이용한 오일쿨러시스템의 최적 PI제어기 설계 (Optimum PI Controller Design for an Oil Cooler System Using GA)

  • 정영미;정석권
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.28-34
    • /
    • 2014
  • This paper deals with optimum PI controller design using genetic algorithm to improve control performance and robustness for an oil cooler system. The optimum PI gain was found to minimize an object function, integrated absolute error, and to satisfy control design specifications such as overshoot and settling time based on practical transfer function of the oil cooler system. The control performance and robustness were investigated by comparing indicial responses and Bode diagram analysis with respect to three kinds of PI gains obtained from different gain decision manners. Moreover, the robustness against to input disturbances, sinusoidal wave form and abrupt single pulse, was evaluated. The computer simulation results showed that the suggested optimum gain can establish desirable control performance and strong robustness with easy design process.

대형 디젤엔진 자동변속기 오일쿨러 냉각팬 성능에 관한 연구 (A Study on Performance of Cooling Fan for Auto Transmission Oil Cooler in the Large-Size Diesel Engine)

  • 이중섭;서정세;송철기;윤지훈
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.71-76
    • /
    • 2010
  • This study has investigated numerically and experimentally the flow characteristic of air-cooling fan for transmission oil cooler in the large-size diesel engine. Impellers of cooler were composed of eight normal-scale and eight small-scale blades in the zig-zag pattern. In order to increase the discharge pressure of cooling fan, turbo type of fan blade is proposed in the impeller for transmission oil cooler. The fluidic performance of cooling fan has been estimated numerically by using the commercial code and experimentally carried out with reference on AMCA Standard 210-99. As a result, it is confirmed that the numerical result for performance curve is in good agreement with experimental data.

모드해석을 이용한 플루가스 냉각기의 진동 저감 방법에 관한 연구 (A Study on the Vibration Reduction of Flue Gas Cooler Using Modal Analysis)

  • 이부윤;김원진
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.664-670
    • /
    • 2012
  • In this work, vibration characteristics of a flue gas cooler(FGC) for a heavy oil upgrading are experimentally analyzed and an effective method is proposed to reduce the vibration level. Firstly, the vibration under the operation condition of the FGC is measured and analyzed to identify the generation phenomena of vibration. And the displacement of the outer wall of the FGC is also analyzed to identify dominant frequencies of vibration. Secondly, an effective design to reduce the vibration is suggested by using the modal analysis. Consequently an improved design of the FGC gas cooler, which has lower vibration level, is obtained and then verified though the analysis and test.

PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정 (An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques)

  • 박철우;백인제
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구 (A study on a uniformity of flow field in a duct cooler of FGD system)

  • 배진효;김광추;박만흥;박경석;이종원
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기 (Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet)

  • 조진표;김내현
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.