• 제목/요약/키워드: coolant

검색결과 1,634건 처리시간 0.03초

CFD 기법을 이용한 실린더헤드 가스켓홀 통과 유량의 최적화 (Numerical Optimization of the Coolant Flow Rates through Cylinder Head Gasket Holes by applying CFD Techniques)

  • 백경욱;이상호;조남효
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.121-128
    • /
    • 2000
  • Simple design methods were developed to control the coolant flow rates through cylinder head gasket holes. Applying the concept of flow through an obstruction the ratio of intake to exhaust side flow rates could be easily controlled while maintaining the flow rates per cylinder of the original model. Flow distribution in the coolant passage of the original model was calculated by CFD and the flow rates at the gasket holes were modified based on the calculation results. The calculated flow rated of the modified gasket holes were reasonably close to target values. For more accurate control of the flow rate distribution, a design method with iterative CFD calculations was also suggested. The final size of gasket holes for the target flow rates were obtained just after a few optimization iterations. These methods can be very useful for the optimization of heat transfer characteristics in engine cylinder head and block.

  • PDF

축소형 칼로리미터의 냉각성능 해석 (Cooling Performance Analysis of a Sub-scale Calorimeter)

  • 조원국;문윤완
    • 한국추진공학회지
    • /
    • 제7권3호
    • /
    • pp.8-14
    • /
    • 2003
  • KSR-III 축소형 엔진을 원형으로 하는 8채널형 칼로리미터의 냉각성능해석을 수행하였다. 축대칭 압축성 해석을 통해서 연소실 벽으로의 열유속을 예측하였으며 이를 이용하여 3차원 냉각유로 내부의 열전달 해석을 수행하였다. 연소실 벽으로의 열유속은 문헌에서 제시하는 수준으로 확인되었으며 열전달 해석을 통하여 칼로리미터 개발과 운용에 필요한 냉각수의 압력강하, 온도상승 및 연소실벽의 최고온도를 제시하였다. 연소실 압력증가에 따른 냉각요구량을 결정하였으며 냉각수의 물성변화에 의한 냉각성능 변화를 예측하였다.

A Study on the Coolant Mixing Phenomena in the Reactor Lower Plenum

  • Park, Yong-Seog;Park, Goon-Cherl;Um, Kil-Sup
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.186-195
    • /
    • 1997
  • When asymmetric thermal-hydraulic conditions occur between cold legs, the core inlet temperature will be nonuniform if the coolant is not mixed perfectly in the lower plenum. These uneven core inlet conditions may induce the change in core power distribution. Thus realistic prediction of thermal mixing is important in such abnormal conditions. In this study, reactor internals, which are scaled down as to conserve the flow area ratio, are set up in the model of KORI Unit 1 with the scaling factor of 1/710 by volume and coolant temperatures are measured beneath the lower core plate. Based on experimental results, the ability of COMMIX-1B code to simulate the coolant mixing phenomena in the lower plenum is estimated. The results show that complete mixing never occurs in any conditions and the mixing pattern is characterized according to the plant type.

  • PDF

DETAILED EVALUATION OF THE IN-VESSEL SEVERE ACCIDENT MANAGEMENT STRATEGY FOR SBLOCA USING SCDAP/RELAP5

  • Park, Rae-Joon;Hong, Seong-Wan;Kim, Sang-Baik;Kim, hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.921-928
    • /
    • 2009
  • As part of an evaluation for an in-vessel severe accident management strategy, a coolant injection into the reactor vessel under depressurization of the reactor coolant system (RCS) has been evaluated in detail using the SCDAP/RELAP5 computer code. A high-pressure sequence of a small break loss of coolant accident (SBLOCA) has been analyzed in the Optimized Power Reactor (OPR) 1000. The SCDAP/RELAP5 results have shown that safety injection timing and capacity with RCS depressurization timing and capacity are very effective on the reactor vessel failure during a severe accident. Only one train operation of the high pressure safety injection (HPSI) for 30,000 seconds with RCS depressurization prevents failure of the reactor vessel. In this case, the operation of only the low pressure safety injection (LPSI) without a HPSI does not prevent failure of the reactor vessel.

전산해석에 의한 일체형 원자로용 주냉각재 펌프의 성능분석 (Performance Evaluation of a Main Coolant Pump for the Modular Nuclear Reactor by Computational Fluid Dynamics)

  • 윤의수;오형우;박상진
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.818-824
    • /
    • 2006
  • The hydrodynamic performance analysis of an axial-flow main coolant pump for the modular nuclear reactor has been carried out using a commercial computational fluid dynamics (CFD) software. The prediction capability of the CFD software adopted in the present study was validated in comparison with the experimental data. Predicted performance curves agree satisfactorily well with the experimental results for the main coolant pump over the normal operating range. π Ie prediction method presented herein can be used effectively as a tool for the hydrodynamic design optimization and assist the understanding of the operational characteristics of general purpose axial-flow pumps.

초전도발전기의 냉각시스템 해석 (Analysis of the cooling system for a superconducting generator)

  • 김국원;정태은;신효철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.446-453
    • /
    • 1997
  • The superconducting winding in rotor of a superconducting generator should be kept at extremely low temperature of 4-5 K to maintain the superconducting state. For this purpose the liquefied helium is used for the coolant and it is very important to analyze and design a cooling system making effective use of the coolant. In this paper, the typical heat exchanger of a superconducting generator with the flow passage is analyzed with regard to the thermal equilibrium. An experimental constant relevant to the flow condition in the flow passage is determined with heat exchange experiments in cryostat. Also a new heat exchanger with porous material is proposed and designed. Results of the numerical analysis for the temperature distributions for the torque tube and the coolant are reported and the efficiency of the heat exchanger is discussed from the viewpoint of amounts of coolant needed.

  • PDF

난삭성 재료의 가공환경변화에 따른 고속가공 특성 평가(압축공기냉각에 의한 공구수명 평가) (Evaluation of Machinability by Cutting Environments in High-Speed Machining of Difficult-to-cut Materials(Test for Tool Life Using Compressed Chilly Air Cooling))

  • 김석원;안철수;이득우
    • 한국생산제조학회지
    • /
    • 제9권6호
    • /
    • pp.158-163
    • /
    • 2000
  • High speed machining of difficult-to-cut materials generates the concentrated thermal/frictional damage at the cutting edge of the tool and rapidly decreases the tool life. In this paper, the cutting environments, such as dry, fluid coolant, and compressed chilly air coolant, were investigated to improve the tool life. For this study, the compressed chilly air system was manufactured. The experiments were performed for various difficult-to-cut materials and various coated tools. The effectiveness of the developed methods on the basis of tool life was estimated. The results show that the cutting environment using compressed chilly air coolant provided better tool life than using the fluid coolant or using the dry.

  • PDF

전자제어식 냉각시스템이 연비에 미치는 영향에 관한 연구 (A STUDY ON THE IMPROVEMENT OF FUEL ECONOMY BY OPTIMIZING AN ELECTRIC ENGINE COOLING SYSTEM)

  • 인병덕;이기형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3001-3006
    • /
    • 2008
  • Recently, the internal combustion engines have focused on reducing both the CO2 emissions in order to cope with severe regulations for greenhouse effect. Therefore, various new technologies have been developed in many countries. Among them, the cooling system is spotlighted because it has great effect on fuel efficiency. However, the present engine cooling system is almost same as one of the 50 years ago. The needs for high performance and compact size make it important to improve engine cooling system, down-sizing and control method of coolant flow. Thus, low fuel consumption technology such as control and synthetic management of cooling system was necessary to satisfy with these needs. In this study, we applied electric thermostat to improve the fuel economy. The fuel consumption was compared after driving FTP-75 mode on both conditions which were with a conventional wax thermostat and with a electric thermostat. The coolant temperature of opening the electric thermostat is higher.

  • PDF

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-251
    • /
    • 1999
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seem that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stresses.

  • PDF

엔진 냉각수 유동통로 모델에 대한 수치해석 : Lotus 모델의 실험 결과와의 비교 및 유량제어 (A Study on Flow Analysis of Model Engine Coolant Flow Passage : Comparison with Experimental Data of Lotus Model and Flow Rate Control)

  • 조원국;허남건
    • 한국자동차공학회논문집
    • /
    • 제3권5호
    • /
    • pp.17-23
    • /
    • 1995
  • A numerical analysis on engine coolant is made by the use of FVM based general purpose 3 dimensional Navier-Stokes solver, TURB-3D. Numerical solutions are verified by comparison with the experimental data of Lotus model. The results show a good qualitative as well as quantitative comparison. Coolant flow rate control is attempted through adjusting the cross section area of passage base on the results of an original coolant passage. It is concluded from the results that the flow rate control is possible as attempted, and thus can be used in the real engine design.

  • PDF