• Title/Summary/Keyword: cool-down phase

Search Result 29, Processing Time 0.055 seconds

Viscoelastic analysis of residual stresses in a unidirectional laminate

  • Lee, Sang Soon;Sohn, Yong Soo
    • Structural Engineering and Mechanics
    • /
    • v.2 no.4
    • /
    • pp.383-393
    • /
    • 1994
  • The residual stress distribution in a unidirectional graphite/epoxy laminate induced during the fabrication process is investigated at the microstress level within the scope of linear viscoelasticity. To estimate the residual stresses, the fabrication process is divided into polymerization phase and cool-down phase, and strength of materials approach is employed. Large residual stresses are not generated during polymerization phase because the relaxation modulus is relatively small due to the relaxation ability at this temperature level. The residual stresses increase remarkably during cool-down process. The magnitude of final residual stress is about 80% of the ultimate strength of the matrix material at room temperature. This suggests that the residual stress can have a significant effect on the performance of composite structure.

Phase Transition and Thermal Expansion Behavior of Zirconia Setter Fabricated from Fused CaO Stabilized Zirconia

  • Park, Ji-Hoon;Bang, Il-Hwan;Lee, Sang-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.2
    • /
    • pp.184-190
    • /
    • 2019
  • To improve resistance in thermal shock of zirconia setter which is frequently and repeatedly exposed to high temperature, high degree of porosity and control of thermal expansion are needed for which the fused CSZ (CaO stabilized zirconia) is used to produce the zirconia setter. In the present study, the effects of sintering temperature, cool down condition, addition of CaO stabilizer, and addition of other additives on phase transition and thermal expansion behavior of the fabrication process of zirconia setter, were examined. The zirconia setter, fabricated with fused CSZ at 1550℃, exhibited 20.4 MPa of flexural strength, 6.8% of absorbance, and 27.9% of apparent porosity. The rapid change in thermal expansion of zirconia setter is observed at temperature around 800℃, and it was reduced by low firing temperature, slowed cooled down, and addition of CaO.

Experimental study on natural circulation using liquid nitrogen for superconducting applications

  • Choi, Yeon Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.49-52
    • /
    • 2013
  • An experiment to investigate the natural circulation of a cryogen has been performed. The study is motivated mainly by our recent development of cryogenic cooling system for prototype superconducting cyclotron without any circulating pump. In the natural circulation loop system, a cooling channel is attached on the outer surface of the aluminium block and the liquid nitrogen passes through inside of the channel to cool the block indirectly. A cryocooler as a heat sink is located at the top to re-condense cryogenic vapor coming from the aluminium block in which electrical heater is installed as a heat source. The main dimensions are determined using the relevant analysis and the natural circulation loop is successfully fabricated. The temperature distributions in the loop are measured during initial cool-down process and in steady state, from which the modified Grashof numbers are calculated and compared with the existing correlation estimated with one-dimensional analysis for steady state flow.

Physical Therapy for Post-Myocardial Infarction (심근경색후 물리치료)

  • Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.83-87
    • /
    • 1994
  • The purpose of this paper is to provide an overview of the clinical physical therapy program used at the University of Yonsei Rehabilitation Hospital, for the practicing university trained physical therapists who may be unfamiliar with patients who have suffered a myocardial infarction. The four primary phases of the cardiac physical therapy graded exercise program are: 1) coronary care unit program (phase I), 2) general ward program (phase II), 3) convalescence program (phase III), 4) maintenance program (phase IV). The exercise prescription defines the exercise intensity, duration, frequency, and mode of exercise a after pre- discharge low level graded exercise test(LL-GXT) or symptom limited maximum graded exercise test. A typical exercise routine consists of preparation warm-up exercise, therapeutic exercise, cool-down exercise. Physical therapy is involved in the acute care and rehabilitation of the patient after a myocardial infarction. Therefore, the physical therapist must throughly comprehened the cardiac anatomy, cycle, performance, conduction system, pathogenesis, risk factors, and exercise benefits.

  • PDF

How Promoting Proprioceptive Exercises Affects Pediatric Cobb's Angle (고유수용성감각기관들을 자극하는 운동법들이 소아 측만 각도 변화에 미치는 효과)

  • Jae-Man Yang;Han-Wook Kang
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.367-376
    • /
    • 2023
  • Purpose: The purpose of this study was to compare changes in pediatric Cobb's angle resulting from using the modified scoliosis exercise method to promote proprioception. Methods: There were 32 participants in this study. Cobb's angle was measured automatically using a ZeTTA PACS Viewer through a digital computer program with whole-body x-ray anterior to posterior. Scoliosis was diagnosed by a Cobb's angle of 10° or higher. Modified scoliosis exercises were used as the program for the three-stage method used in the study: the preparation phase (warm-up), actual exercise phase (main exercise), and final clean-up phase (cool-down). In this study, exercises that can promote proprioception, including muscle strengthening, stretching, equilibrium, myofascial release, balance taping, and traction, were applied, and their effects before and after treatment were compared. After implementing the exercise methods once a week-15 times total for about 4 months-the changes in Cobb's angle were measured. Results: After having the pediatric scoliosis patients practice the modified scoliosis exercises for four months, it was found that the Cobb's angle of the spine significantly decreased. Conclusion: The results of this study show that the modified pediatric scoliosis exercise, which is capable of promoting proprioception, is also effective in improving Cobb's angle.

NATURAL CIRCULATION ANALYSIS CONSIDERING VARIABLE FLUID PROPERTIES WITH THE CUPID CODE (CUPID 코드의 유체 물성치 변화를 고려한 자연대류 해석)

  • Lee, S.J.;Park, I.K.;Yoon, H.Y.;Kim, J.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.14-20
    • /
    • 2015
  • Without electirc power to cool down the hot reactor core, passive systems utilizing natural circulation are becoming a big specialty of recent neculear systems after the severe accident in Fukusima. When we consider the natural circulation in a pool, thermal mixing phenomena may start from single phase circulation and can continue to two phase condition. Since the CUPID code, which has been developed for two-phase flow analysis, can deal with the phase transition phenomena, the CUPID would be pertinent to natural convection problems in single- and two-phase conditions. Thus, the CUPID should be validated against single- and two-phase natural circulation phenomena. For the first step of the validation process, this study is focused on the validation of single-phase natural circulation. Moreover, the CUPID code solves the fluid properties by the relationship to pressure and temperature from the steam table considering non-condensable gas effects, so that the effects from variable properties are included. Simple square thermal cavity problems are tested for laminar and turbulent conditions against numerical and experimental data. Throughout the investigation, it is found that the variable properties can affect the flow field in laminar condition, but the effect becomes weak in turbulence condition, and the CUPID code implementing steam table is capable of analyzing single phase natural circualtion phenomena.

An Example of Modification of Design Validation Test Specification to Reduce the Environmental Durability Test Time of Electronic Control Unit for Motor-Driven Power Steering system (전동식 조향 장치용 ECU 의 환경 내구 시험 시간 단축을 위한 설계 검증 시험 사양 변경 사례)

  • Kim, Tae-Hun;Kang, Dong-Young;Chung, In-Seung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1309-1313
    • /
    • 2008
  • This paper suggests an example of modification of the durability test specifications of electronic control unit for an automotive system in phase of design validation. The basic concept to redefine the specifications of durability test is based on the Arrhenius relationship for accelerated temperature test and the modified Coffin-Manson model for temperature cycle test. The ambient temperature of the powered-event durability test is increased to reduce the required test time of the current specification. Furthermore, the holding time between the events to cool down the temperature of the components is shortened and the resultant temperature rise affects the durability of the components. Thus, the acceleration factor due to the increased temperature range of temperature cycle is also estimated by the modified Coffin-Manson model.

  • PDF

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

The Electronic Laser Interferometry and Laser Heating Method for Residual Stress Determination

  • Kim, Koung-Suk;Kang, Young-June;Rho, Kyung-Wan;Ryu, Weon-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.7
    • /
    • pp.715-721
    • /
    • 2000
  • Residual stress is one of the causes which makes defects in engineering components and materials. These residual stresses can occur in many engineering structures and can sometimes lead to premature failures. There are commonly used methods by which residual stresses are currently measured. But these methods have a little damage and other problems; therefore, a new experimental technique has been devised to measure residual stress in materials with a combination of electronic laser interferometry, laser heating and finite element method. The electronic laser interferometer measures in-plane deformations while the laser heating and cooling provides for very localized stress relief. FEM is used for determining the heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heat-up and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method.

  • PDF

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • Jeong, Hyeon-Ju;Lim, Ju-Hee;Lee, Sung-Hoo;Deen, Casey;Pak, Soo-Jong;Yuk, In-Soo;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF