Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination (초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석)

  • Cheol-Min, Jeon;Jae-Bok, Han;Jong-Gil ,Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.751-759
    • /
    • 2022
  • Currently, ultrasound examination for diagnostic ultrasound and health examination purposes is widely used, and it is showing an increasing trend due to the application of health insurance. However, the risk of ultrasound has not been clearly identified so far, and in this study, surface and deep temperature changes according to frequency and mode were measured by using a tissue mimicking phantom and TI and MI values were compared. A simulated phantom was manufactured by adding a small amount of kappa-caraginan powder with acoustic characteristics similar to that of the human body and potassium chloride for solidification, and the change of surface and depth temperature was measured using a surface thermometer and a probe thermometer. As a result, the convex probe using low frequency showed a higher temperature increase than the linear probe using high frequency, so there was a significant difference, and the temperature increase was the highest on the surface, and the depth of 1cm showed a temporary temperature increase, but there was no significant temperature change. There was no change in the deep temperature of 5 cm to 15 cm, and the TI and MI values did not change during the test time. Since only the surface temperature rose during the 15-minute test and there was no temperature change in the core, so it is not expected to show a temperature change that is harmful to the human body. However, it is thought that prolonged examination of one area may cause temperature rise, so it should be avoided.

A Study on the Necessity Verification of Convex Probe Disinfection (Convex Probe 소독 필요성 검증에 관한 연구)

  • Choi, Kwan-Yong;Yoo, Se-jong;Lee, Jun-ho;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • The study was conducted surveying ultrasound room workers on hospital infection awareness in Daejeon and Choong-chunng region. The contamination of ultrasonic probes used in clinical trials was measured using ATP, and the results were verified after using 70% alcohol sterilization. It was measured on the group's general characteristics and the specific categories such as academic background, job type, having professional certificate and infection education. After the examination, the gel removal and method, disinfection status of the probe and variable correlation analysis were performed to analyze the recognition of the ultrasonic probe disinfection. After examination in ultrasound room, it was found that towels were used the most for cleaning, and the gel container was not replaced for more than three months. After 70% alcohol disinfection, ATP contamination was reduced from $1055.4{\pm}944.2$ to $133.5{\pm}93.2$ and the result was analyzed to be statistically significant.(${\rho}<0.01$) The found bacteria were CNS, Gram positive bacillus, and Micrococcus specs. In order to solve this problem, 70% alcohol sterilization was applied and the bacteria were not detected after the treatment. The research shows that regular training on infection control and efforts to prevent infection are necessary, and that 70% alcohol is effective in disinfect the bacteria. Therefore, the medical institution should provide active hospital infection control education to improve the awareness of hospital infection among workers and contribute to the prevention of patient infection. It is also understood that proper use of the results of this study will help prevent infection by means of ultrasonic probes.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials (신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구)

  • Ma, Sang-Chull;Kim, Hwa-Sun;Ann, Young-Man
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This study analyzed speed of sound, impedance, attenuation coefficient in accordance with acoustic characteristic standard of body soft tissue corresponding with Annex DD of IEC standard 60601-2-37(2007) which is about tissue mimicking materials (TMM) synthesized by polyurethane as a main material and new type of n-type scatter materials. This study reached the following conclusion after analyzing and evaluating image characteristic with SONOACE 9900 c PRIME (MEDESON Co.) and brightness, maximum penetration with convex probe (2.5~5.0 MHz). When n-type scatter materials are increasingly synthesised 0~8% with prepolymer as a main material and polyol mixture as a catalyst, 1. The more scatter materials are increased, the more sound speed of TMM becomes closely similar to soft tissue. 2. The more scatter materials are decreased, the more acoustic impedance becomes closely similar to soft tissue. 3. The more scatter materials are increased, the more attenuation coefficient is increased. 4. The more scatter materials are increased, the more average brightness of images is increased, but there is threshold. 5. The maximum penetration becomes closely similar to soft tissue at the 6% TMM as a scatter material.

Comparison of Ultrasonography and Video-otoscopy for the Evaluation of the Tympanic Membrane in Otitis Dogs (외이염 발생견에서 고막평가를 위한 초음파 및 이경 검사법 비교)

  • Lee Jong-won;Eom Ki-dong;Seong Yun-sang;Lee Hae-oon;Moon Kum-jung;Bae Sun-hee;Byun Tae-Kyung;Song Gyoung-ho;Jeon Jong-hoon;Jang Kwang-ho;Oh Tae-ho;Lee Keun-woo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.382-385
    • /
    • 2005
  • The aim of this study was to compare ultrasonography with video-otoscopy for the evalution of the external ear canal and the tympanum. Fifty dogs with clinical signs ot the bilateral ear diseases were examined using otoscopy under general anesthesia. Ultrasonographic examination was performed with an 11 MHz linear-arrary probe and a 6.5MHz convex probe, with the external ear canal filled with saline. Saline functioned as a contrast media and enhanced image quality of ultrasonography. The images of 100 ears before and after the ear cleansing were obtained at otoscopy and ultrasonography. On the video-otoscopic images, the tympanic membrane was identified in 59 ears before the ear cleansing and 91 ears after cleansing. On the ultrasonography, the tympanic membrane was detected in 98 ears before the ear cleansing and in all ears after cleansing. With these results, it was concluded that ultrasonography with infusing saline into the ear canal, could be a useful diagnostic procedure to identify the tympanic membrane in otitis dogs.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

Analyzing Image Quality and Disinfection Effectiveness of Alcohol Gel Application in Ultrasound Scans (초음파 스캔에서 알코올 겔 적용 시 화질과 소독효과 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.365-372
    • /
    • 2024
  • To analyze the image quality and disinfection effectiveness of alcohol gel application in ultrasound scans, we varied the application of alcohol gels with different alcohol content from ultrasound gels. The image quality analysis compared the Dead zone, axial and lateral resolution, sensitivity, and gray scale changes using the ATS-539 phantom, while the disinfection effectiveness analysis was performed by swabbing the three cover faces of convex probe used in clinical practice, collecting specimens and enrichment culture them for 24 hours before identification with Gram stain. image quality analysis showed that all items, regardless of the alcohol content, produced images that were not different from the ultrasonic gel application images, and pathogens such as staphylococcus aureus, streptococcus, and enterococcus were detected on all probes, and all were extinction by the application of alcohol gel. The application of alcohol gel during ultrasound examination was meaningful in terms of image quality maintenance and disinfection effect, and if the results of this study are further studied and commercialized, the application of alcohol gel as an alternative to ultrasound gel will be very useful in clinical examinations because it can consider not only image quality but also infection prevention.

Identification of High Frequency Peakers with long-term monitoring observation at 22 and 43 GHz

  • Jeong, Yongjin;Sohn, Bong Won;Chung, Aeree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.68.2-68.2
    • /
    • 2014
  • High Frequency Peakers (HFPs) are radio-loud Active Galactic Nuclei (AGN), which are regarded as being in the earliest evolutionary phase (102-103 years) of radio galaxies. They are expected to be small in size (< ~1 kpc) compared to their host galaxies (~a few 10s kpc), and have convex spectra, which are peaking at high radio frequency (> 5 GHz). Their size and spectral shape are the most obvious supporting evidence of extremely young ages. HFPs are therefore ideal targets to probe the earliest stage of radio sources. To date however, the young radio source classification has been relying mainly on the spectral shape which usually does not cover high enough frequencies where the true peak flux is located. Hence HFPs are often confused with blazars which may show a similar spectral shape and apparent compactness but are a somewhat evolved form of AGNs. Therefore, we have been challenging to identify HFPs among the sample of 19 candidates using the Korean VLBI Network (KVN) which enables us to extend the radio spectrum baseline up to 22 and 43 GHz. These are higher than the frequencies used in most previous studies of HFPs, allowing us to select genuine HFPs. By long-term monitoring of 18 epochs, we have also inspected the variability of the sample to select out blazars which are highly variable yet with a similar radio spectrum. In this work, we present the light curves and spectral properties of the HFP candidates. We discuss the results of our re-identification of HFPs.