• 제목/요약/키워드: conventional water treatment

검색결과 567건 처리시간 0.028초

Permeability of anion-exchange membrane for Cl- ions. Dialysis of hydrochloride acid in the presence of nickel chloride

  • Palaty, Zdenek;Bendova, Helena
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.39-47
    • /
    • 2010
  • Using a conventional two-compartment cell with stirrers the separation of an aqueous solution of HCl-$NiCl_2$ by an anion-exchange membrane Neosepta-AFN was investigated. The dialysis process was characterized by the permeability coefficient of the membrane towards to $Cl^-$ ions. This quantity was determined by the numerical integration of equations, which describe the time dependence of the total concentration of $Cl^-$ ions in compartment initially filled with stripping agent (water), combined with an optimizing procedure. The analysis of the experimental results showed that this permeability coefficient is a satisfactory characteristic for the process studied. It can be graphically correlated with the initial acid and initial salt concentrations in the compartment initially filled with acid+salt mixture.

Ion Exchange Processes: A Potential Approach for the Removal of Natural Organic Matter from Water

  • Khan, Mohd Danish;Ahn, Ji Whan
    • 에너지공학
    • /
    • 제27권2호
    • /
    • pp.70-80
    • /
    • 2018
  • Natural organic matter (NOM) is among the most common pollutant in underground and surface waters. It comprises of humic substances which contains anionic macromolecules such as aliphatic and aromatic compounds of a wide range of molecular weights along with carboxylic, phenolic functional groups. Although the concentration of NOM in potable water usually lies in the range of 1-10 ppm. Conventional treatment technologies are facing challenge in removing NOM effectively. The main issues are concentrated to low efficiency, membrane fouling, and harmful by-product formation. Ion-exchangers can be considered as an efficient and economic pretreatment technology for the removal of NOM. It not only consumes less time for pretreatment but also resist formation of trihalomethanes (THMs), an unwanted harmful by-product. This article provides a comprehensive review of ion exchange processes for the removal of NOM.

Synthesis and Thermo-mechanical Property of Multi-walled Carbon Nanotubes/Poly(methyl methacrylate-co-butyl acrylate) Nanocomposites Prepared Using Emulsion Polymerizations in the Presence of Amphiphilic Random Terpolymer

  • Chang, Woo-Hyuck;Ki, Ho-Seong;Cheong, In-Woo
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.289-289
    • /
    • 2006
  • The carboxylated MWNTs were successfully prepared by conventional acid treatment, and their structures were confirmed by FT-IR, Raman and TEM analysis. The water-dispersibility of the surface modified WNTs were good. The COOH-MWNT will show better stability during the emulsion polymerization as compared with Pristine MWNT. In-situ emulsion polymerizations of methyl methacrylate N(MMA) and n-butyl acrylate (BA) were carried out. Aggregate size and dispersion stability of the CNTs in water phase were measured using dynamic light scattering, turbidity, UV-visible spectrophotometer, and electron microscope. In addition, thermo-mechanical properties of MWNT/polymer nanocomposites were investigated.

  • PDF

Degradation of 1,4-Dioxane using $O_3$/$H_2O_2$

  • Suh, Jung-Ho;Mohseni, Madjld
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.139-144
    • /
    • 2003
  • 1, 4-dioxane is a recalcitrant pollutant found in contaminated ground waters and industrial effluents. Conventional water treatment techniques are limited to treat this compound effectively. In this study, $O_3$$H_2O_2$ oxidation process was used to eliminate 1, 4-dioxane in water and to enhance the biodegradability. Several factors affecting biodegradability enhancement were investigated. The relationship between initial oxidation rate of 1 A-dioxane and BOD enhancement rate has been determined, a kinetic model has been proposed. $H_2O_2$ concentration and pH had a proportional relation with biodegradability of 1, 4-dioxane, but in case of ozone, there was no relationship with biodegradability. 1, 4-Dioxane removal efficiencies had good agreement with the biodegradability.

  • PDF

오수처리수의 관개가 벼의 생육 및 수확량에 미치는 효과(지역환경 \circled3) (Effect of Reclaimed Sewage Irrigation on Paddy Rice Culture and Yields)

  • 우선호;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.611-616
    • /
    • 2000
  • Effect of reclaimed sewage on the paddy rice culture was examined by field experiment for two consecutive years. The domestic sewage was treated by the comstructed wetland, and the effluent of the treatment wetland was used for irrigation water. Growth components and yields were compared against the CONTROL plot where conventional fertilization was applied. In general, addition of the reclaimed sewage irrigation which contained high nutrient concentration didn't affect paddy rice culture adversely, and even better growth and more yields were observed. Overall, reclaimed sewage irrigation was thought to be one of practical alternatives for irrigation water.

  • PDF

마그네타이트 분말의 표면개질화에 의한 부유물질의 고속 제거 (Study on Rapid Removal of Suspended Solid by Modified Magnetite Powder)

  • 이혁희;박상원
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.1017-1023
    • /
    • 2003
  • The high speed elimination process of suspended solid was investigated to treat the pulp waste water by using surface modified magnetite particle and magnetic power. The effects of the various aluminum salts such as Al(NO$_3$)$_3$ㆍ9$H_2O$, AlC1$_3$ㆍ6$H_2O$, $Al_2$(SO$_4$)$_3$ㆍ13∼14 on the COD, BOD and suspended solid were systematically studied. It has been found that the 2.0 wt% of Al was most effective for the modification of Fe$_3$O$_4$ powder and then best for the treatment of pulp waste water, Optimum quantity of modified magnetite in this study was 12 wt%, and aging time was found to be 12 hours. Comparing with the conventional process, the required time for SS removal was drastically decreased. BOB and COD were also effectively removed when applied to the pulp wastewater.

Effects of EPS on membrane fouling in a hybrid membrane bioreactor for municipal wastewater treatment

  • Zhang, Aining;Liu, Zhe;Chen, Yiping;Kuschk, Peter;Liu, Yongjun
    • Membrane and Water Treatment
    • /
    • 제5권1호
    • /
    • pp.1-14
    • /
    • 2014
  • A pilot-scale hybrid membrane bioreactor (HMBR) for real municipal wastewater treatment was developed by adding biofilm carriers into a conventional membrane bioreactor, distribution and dynamic changes of the extracellular polymeric substances (EPS) and their roles in membrane fouling were investigated. The results showed that the concentrations of loosely bond EPS (LB-EPS) and tightly bond EPS (TB-EPS) in activated sludge, carrier biofilm and sludge cake layer have been increased significantly with the running time of HMBR, during operation of the HMBR, EPS demonstrated positive correlations with membrane fouling. Compared to TB-EPS, LB-EPS showed more significant correlations with sludge physical properties and specific resistance to filtration (SRF) in HMBR, and thus demonstrated that LP-EPS have a stronger potential of fouling than TB-EPS. It was also found that a lower organic loading in HMBR could result a significant increase in EPS concentration, which would in turn influence membrane fouling in HMBR. This critical investigation would contribute towards a better understanding of the behavior, composition and fouling potential of EPS in HMBR operation.

Intradermal Therapy (Mesotherapy) for the Treatment of Acute Pain in Carpal Tunnel Syndrome: A Preliminary Study

  • Conforti, Giorgio;Capone, Loredana;Corra, Stefano
    • The Korean Journal of Pain
    • /
    • 제27권1호
    • /
    • pp.49-53
    • /
    • 2014
  • Background: The carpal tunnel syndrome (CTS) is the most common cause of severe hand pain. In this study we treated acute pain in CTS patients by means of local intradermal injections of anti-inflammatory drugs (mesotherapy). Methods: In twenty-five patients (forty-five hands), CTS diagnosis was confirmed by clinical and neurophysiological examination prior to mesotherapy. A mixture containing lidocaine 10 mg, ketoprophen lysine-acetylsalycilate 80 mg, xantinol nicotinate 100 mg, cyanocobalamine 1,000 mcg plus injectable water was used. Sites of injection were three parallel lines above the transverse carpal ligament and two v-shaped lines, one at the base of the thenar eminence, and the other at the base of the hypothenar eminence. Results: The day after the treatment, all but four patients reported a significant reduction in pain and paresthesias. After 12 months, 17 patients had a complete pain relief, eight patients reported recurrence of pain and sensory symptoms and four out of them underwent surgical treatment. Conclusions: With the obvious limits of a small-size open-label study, our results suggest that mesotherapy can temporary relieve pain and paresthesias in most CTS patients and in some cases its effect seems to be long-lasting. Further controlled studies are needed to confirm our preliminary findings and to compare mesotherapy to conventional approaches for the treatment of CTS.

연속흐름식 반응기를 이용한 모노-, 디-, 트리 클로로페놀의 광촉매반응에 관한 연구 (Photocatalytic Degradation of Mono-, Di-, Tri-chorophenols using continuous Flow Reactor)

  • 이상협;박중현
    • 상하수도학회지
    • /
    • 제12권1호
    • /
    • pp.88-95
    • /
    • 1998
  • The Electron/Hole Pair is generated when the Activation Energy produces by Ultraviolet Ray illumination to the Semiconductor. And $OH^-$ ion produces by Water Photo-Cleavage reacts with Positive Hole. As a result, OH Radical acting as strong oxidant is generated and then Photocatalytic Oxidation Reaction occurs. The Photocatalytic Oxidation can oxidize the chlorophenol to Chloride and Carbon Dioxide easier, safer and shorter than conventional Water Treatment Process With the same degree of chlorination, the $Cl^-$ ion at para (C4) position is most easily replaced by the OH radical. And then, the blocking effect of $OH^-$ ion between the $Cl^-$ ions and $Cl^-$ ions at symmetrical location is easily replaced by the OH radical. For mono-, di-, tri-chlorophenols, there is no obvious difference in decomposition rate, decomposition efficiency and completeness of the decomposition reaction except for 2,3-dichloropheno, 2,4,5-, 2,3,4-trichlorophenol. The decomposition efficiency is higher than 75% and completeness of the decomposition reaction is higher than 70%. Therefore, continuous flow photocatalytic reactor is promising process to remove the chlorinated aromatic compounds which is more toxic than non-chlorinated aromatic compound.

  • PDF

입상여과에서 입자물질의 부착 (Particle Attachment in Granular Media Filtration)

  • 김진근
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.666-672
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and pH control was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPD of the effluent did not keep moving from less negative to more negative during the later stages of filtration, and this result was thought to be caused by two reasons: ripening effects and the detachment of flocs.