• 제목/요약/키워드: conventional water treatment

검색결과 567건 처리시간 0.026초

고도정수처리 과정에서 퍼클로레이트 이온의 농도 변화 (Perchlorate in Advanced Drinking Water Treatment Process)

  • 김현구;김정화;이연희;이재호;김산
    • 한국물환경학회지
    • /
    • 제24권2호
    • /
    • pp.164-168
    • /
    • 2008
  • Perchlorate, which is still unregulated, is found in tap water, posing a threat to public health. In and out of Korea, there is no clear standard for drinking water quality or discharge. To make matters worse, Perchlorate study is in its infancy in Korea. This research tracked fresh water and purified water of water purification facility A and B located at the city of D, where Nak-dong River is being utilized as the purified water. And it was found that purified water shows no particular pattern in Perchlorate concentrations but represented a higher level of concentration compared to fresh water. With utilizing the research results, the study sought the impact of activated-carbon treatment process on Perchlorate elimination and found out that Perchlorate concentrations increased 38% after the process. The result proves that conventional water purification process can't eliminate Perchlorate. Therefore, it is reasonable that Perchlorate discharge from sources should be minimized.

중공사형 한외여과막 수처리 공정의 기능성과 막을 사용한 수처리공정의 경제성에 관한 연구 (Technical Feasibility for Hollow-Fiber Ultrafiltration Water Treatment System and its Economic Aspects)

  • 왕진수;김병직;최수형
    • 공업화학
    • /
    • 제10권1호
    • /
    • pp.12-18
    • /
    • 1999
  • 상수를 처리하기 위한 공정으로 막여과 수처리 공정을 택하였다. 재래식 수처리 공정과의 비교를 위하여 막사용 수처리 공정의 기능성과 경제성에관한 연구를 하였다. 기능성을 보기 위해서 막분리중에서 막의 기공의 크기가 $0.01{\mu}m$인 한외여과막을 선택하여 탁도 제거 성능을 실험하였다. 탁도 제거 실험은 유입원수의 탁도를 임의로 10에서 85 NTU로 조절하여 세 가지 탁도에서 실험을 하였다. 모든 실험에서 여과막을 통과한 처리수의 탁도는 균질하게 1 NTU 이하로 측정이 되었다. 이 결과는 한외여과막 공정은 원수의 탁도가 증가하여도 일정한 탁도의 처리수를 생산함을 나타낸다. 막여과 공정의 경제성을 검토하기 위하여 막여과처리 비용계산 프로그램을 작성하였다. 실험은 한외여과막으로 한정하여 실시하였지만, 막여과처리 비용계산은 정밀여과막, 한외여과막, 그리고 저압역삼투압 방식을 포함하였다. 먼저 비용계산 프로그램을 사용하여 생산량 및 단위 면적당 투과량에 따른 처리수 생산단가의 변화를 보았다. 그 결과 생산량 및 투과량이 감소할수록 처리비용이 급격히 증가하였다. 그리고 처리용량을 달리 하였을 때 정밀여과막, 한외여과막, 저압역삼투압, 재래식공정, 그리고 고도처리 공정의 다섯 가지 공정에 대하여 총 비용을 계산하였다. 그 결과 막여과 공정은 재래식 공정 및 고도 처리공정과 비교하여경제성이 있게 나타났고 막분리중에서도 한외여과막은 중용량 ($157.5m^3/hr$) 생산량 이상에서 다른 막분리공정과 비교해서 생산가 경쟁력이 있는 것으로 나타났다.

  • PDF

Field instrumentation and settlement prediction of ground treated with straight-line vacuum preloading

  • Lei, Huayang;Feng, Shuangxi;Wang, Lei;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • 제19권5호
    • /
    • pp.447-462
    • /
    • 2019
  • The vacuum preloading method has been used in many countries for ground improvement and land reclamation works. A sand cushion is required as a horizontal drainage channel for conventional vacuum preloading. In terms of the dredged-fill foundation soil, the treatment effect of the conventional vacuum preloading method is poor, particularly in Tianjin, China, where a shortage of sand exists. To solve this problem, straight-line vacuum preloading without sand is widely adopted in engineering practice to improve the foundation soil. Based on the engineering properties of dredged fill in Lingang City, Tianjin, this paper presents field instrumentation in five sections and analyzes the effect of a prefabricated vertical drain (PVD) layout and a vacuum pumping method on the soft soil ground treatment. Through the arrangement of pore water pressure gauges, settlement marks and vane shear tests, the settlement, pore water pressure and subsoil bearing capacity are analyzed to evaluate the effect of the ground treatment. This study demonstrates that straight-line vacuum preloading without sand can be suitable for areas with a high water content. Furthermore, the consolidation settlement and consolidation degree system is developed based on the grey model to predict the consolidation settlement and consolidation degree under vacuum preloading; the validity of the system is also verified.

이온 보조 반응법에 의한 친수성 처리가 충전재 특성값에 미치는 영향 (Effects of Hydrophilic Treatment by IAR Method on the Packing Characteristic Value)

  • 김진호;최충현;강병하;이재헌
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.554-560
    • /
    • 2001
  • Hydrophilic treatment of the packing materials in a cooling tower has been made by the ion assisted reaction (IAR) method to increase the wettability of the packing materials. The effects of hydrophilic treatment of packing materials on the performance of a cooling tower have been investigated in a wide range of operating parameters, such as water flow rate, air flow rate, and the water inlet temperature. A pilot cooling tower has been designed and built to model a counter-flow cooling tower. The results obtained indicate that the packing characteristic value with hydrophilic packing could be substantially increased by 6∼19.3% than that with conventional packing in the operating ranges considered. The correlations of the packing characteristic value as a function of water-to-air ratio are suggested for a counter-flow cooling tower with hydrophilic packing as well as with conventional packing.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

Ultrafiltration membranes for drinking-water production from low-quality surface water: A case study in Spain

  • Rojas-Serrano, Fatima;Alvarez-Arroyo, Rocio;Perez, Jorge I.;Plaza, Fidel;Garralon, Gloria;Gomez, Miguel A.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.77-94
    • /
    • 2015
  • Ultrafiltration membranes have several advantages over conventional drinking-water treatment. However, this technology presents major limitations, such as irreversible fouling and low removal of natural organic matter. Fouling depends heavily on the raw-water quality as well as on the operating conditions of the process, including flux, permeate recovery, pre-treatment, chemical cleaning, and backwashing. Starting with the premise that the optimisation of operating variables can improve membrane performance, different experiments were conducted in a pilot plant located in Granada (Spain). Several combinations of permeate and backwashing flow rates, backwashing frequencies, and aeration flow rates were tested for low-quality water coming from Genil River with the following results: the effluent quality did not depend on the combination of operating conditions chosen; and the membrane was effective for the removal of microorganisms, turbidity and suspended solids but the yields for the removal of dissolved organic carbon were extremely low. In addition, the threshold transmembrane pressure (-0.7 bar) was reached within a few hours and it was difficult to recover due to the low efficiency of the chemical cleanings. Moreover, greater transmembrane pressure due to fouling also increased the energy consumption, and it was not possible to lower it without compromising the permeate recovery. Finally, the intensification of aeration contributed positively to lengthening the operation times but again raised energy consumption. In light of these findings, the feasibility of ultrafiltration as a single treatment is questioned for low-quality influents.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

사진측량을 이용한 초구장 기본 계획에 관한 연구 (A Study on the Basic Planning of Country Club Using Photogrammetry)

  • 유복모;조기성;박성규
    • 한국측량학회지
    • /
    • 제8권1호
    • /
    • pp.31-40
    • /
    • 1990
  • 본 연구는 사친 측량을 이용한 효율적인 초구장 기본 계획을 수립하고자 연구 대상지를 선정하여 종래 방법과 사진측량 방법을 비교 분석하였다. 또한, 대상지 항공사진과 지형도를 이용하여 사친 판독에 의해 식생, 수계도를 작성하고, 대상지를 격자로 구성하여 수치지형모델에 의한 지형 변화 및 경관을 예측하므로서 계획에 필요한 여러 요소를 종래방법과 비교 고찰하였다. 본 연구 결과 사진 판독에 식생도 및 수계도를 작성하므로서 기존 조사방법 보다 세밀한 결과를 얻을 수 있었고, 수치지형모델을 이용하여 지형, 경관 및 수계 등의 변화를 표현, 예측하므로서 우수처리, 경관, 조경 계획을 효율적으로 할 수 있었다. 또한, 항공사진과 지형도를 병용하므로서 토지 이용 계획과 기타 계획에 관하여 종래 방법보다 효율적임을 제시할 수 있었다.

  • PDF